4 floors · 17 apartments · 17,802 sq ft · built 2020 · class D1 · owner of record: 152 Richards St. Llc

2open violations
$12,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
69dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 69 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 69 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 85 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 313 days
Registered through 2027-09-01

Open violations

ECB / OATH (4) · $12,500 owed
IssuedViolationHearingBalance
Sep 20, 2021Construction CLASS - 1
GUARDRAILS MISSING ATOI OF PROPOSED 4STYNB OBSERVED ACTIVE CONST SITE W/APRX10WORKERS THRUOUT BLDG.OBSERVED NO GUARDRAILS IN PLACE@EXP1 OPENING ON 2FL,ALSO OBSERVED INADEQUATE GUARDRAILS@FLS ABOVE-LOOSE CABLES;
#35589910L
Feb 2, 2022
IN VIOLATION
$2,500
Sep 20, 2021Construction CLASS - 1
BC3314.4 SUPPORTED SCF NOT MAINTAINED AS PER CODE.ATOI OF PROPOSED 4STYNB OBSERVED SUPPORTED SCF IN PLACE@EXP1,2,3&WORKER ON SCF.SCF MISSINGTIEBACKS AS PER PLANS,HAD PLANKS NOT ATTACHED,MISSING PINS,NOT FULLY P
#35589909Y
Feb 2, 2022
IN VIOLATION
$2,500
Sep 20, 2021Unknown CLASS - 2
CONST SUPER FAILED TO PERFORM DUTIES AS PER CODE.ATOI OF PROPOSED 4STYNB ACTIVE JOBSITE OBSERVED MULTIPLE HAZARDOUS CONDITIONS:UNSAFE SUPPORTED SCF W/WORKER ON IT,GUARDRAILS MISSING OR INADEQUATE THRUOUT BLDG,S
#35589908M
Feb 2, 2022
IN VIOLATION
$2,500
Jun 14, 2021Construction CLASS - 2
FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTE: AT TIME OF INSPECTION OF 4 STY NEW BLDG,ACTIVE JOBSITE W/FINISHES & EXTERIOR PHASE. I OBSERVED THAT THERE IS A CONSTRUCTION
#35574784H
Dec 20, 2021
IN VIOLATION
$5,000
DOB (2)
IssuedViolationStatus
Sep 2, 1997IMMEDIATE EMERGENCY

#214/97
DOB VIOLATION - ACTIVE
Aug 20, 1996UNSAFE BUILDINGS

#3177/96
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 2:02 PM ET. BBL 3005560024.