14 floors · 423 apartments · 445,950 sq ft · built 1958 · class D4 · owner of record: Earl W Jimerson Housing Co Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 16 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 65 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 65 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 81 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 445,950 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3634). Agency page | Dec 31, 2034 in 2987 days | Next due 2034 |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-15 (Accepted). Agency page | On file | 2026 reports accepted |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $271,500 in late-filing or failure-to-file penalties. Agency page | On file | Cycle 10 filing on record: SWARMP (2026-06-11) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 11, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTE:OBSERVED LARGE STEP CRACKING AT SE CORNER OF EXP#3(EAST ELEVATION)ON 14TH FL PARAPET LEVEL.ALSO OBSERVED HAIRLINE CRACKS AND OPEN/MISSING MORT #35682325R | May 15, 2024 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 29, 2025 | CONSTRUCTION BOROUGH COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDER PERMIT #B01041814-I1 ON 10/22/25. INTENT TO REVOKE APPROVAL AND PERMIT. STOP ALL WORK EXCEPT TO MAKE SITE SAFE. #25-03342 | DOB VIOLATION - ACTIVE |
| Dec 5, 2006 | ELEVATOR #9444/183072 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #37382 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #37383 | DOB VIOLATION - ACTIVE |
| Mar 6, 1992 | ELEVATOR #E5Y1103D02 | VIOLATION UNSERVED ECB-ACTIVE |
| Mar 6, 1992 | ELEVATOR #E5Y1103D03 | VIOLATION UNSERVED ECB-ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 29, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES TO DOOR AT STAIR CASE B AT PUBLIC HALL STAIRS, 12th STORY | Oct 13, 2026 |
| Sep 29, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES TO DOOR AT BUILDING ENTRANCE AT PUBLIC HALL, 1st STORY | Oct 13, 2026 |
| Apr 28, 2026 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE CEILING AT PUBLIC HALL, 14th STORY | Jun 2, 2026 |
| Apr 28, 2026 | C | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 14th STORY | May 4, 2026 |
| Apr 27, 2026 | B | Apt 14B · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 14B, 14th STORY, 3rd APARTMENT FROM NORTH AT EAST | Jun 1, 2026 |
| Apr 27, 2026 | C | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AT PUBLIC HALL, 14th STORY | May 3, 2026 |
| Apr 27, 2026 | B | Apt 14B · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 14B, 14th STORY, 3rd APARTMENT FROM NORTH AT EAST | Jun 1, 2026 |
| Apr 27, 2026 | A | Apt 14B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 14B, 14th STORY, 3rd APARTMENT FROM NORTH AT EAST | Jul 31, 2026 |
| Apr 27, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT PUBLIC HALL, 14th STORY | Jun 1, 2026 |
| Apr 27, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 14th STORY | Jul 31, 2026 |
| Apr 27, 2026 | B | Apt 14B · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 14B, 14th STORY, 3rd APARTMENT FROM NORTH AT EAST | Jun 1, 2026 |
| Jan 2, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE 1ST FIRE DOOR FROM EAST MISSING AT PUBLIC HALL | Jan 16, 2026 |
| Dec 31, 2025 | C | Apt 2J · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Dec 31, 2025 |
| Nov 12, 2024 | B | Apt 6A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT 2ND CLOSET FROM EAST AT SOUTH IN THE 1st ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Dec 17, 2024 |
| Nov 12, 2024 | B | Apt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS AT 2ND CLOSET FROM EAST AT SOUTH IN THE 1st ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Dec 17, 2024 |
| Nov 12, 2024 | B | Apt 6A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FEET OF MOLD AT ALL WALLS AND CEILING AT CLOSET IN THE PRIVATE HALLWAY LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Dec 17, 2024 |
| Feb 5, 2024 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AT PUBLIC HALL, 14th STORY | Mar 11, 2024 |
| Feb 5, 2024 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE AT PUBLIC HALL, 14th STORY | Mar 11, 2024 |
| Dec 29, 2023 | B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT( APPROXIMATELY 1SQFT ) CEILING , BUILDING VESTIBULE, AT PUBLIC HALL, 1st STORY ORIGINAL VIOLATION 16198138 ISSUED 30-AUG-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). | Feb 2, 2024 |
| Aug 31, 2023 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT, BUILDING' S VESTIBULE , AT PUBLIC HALL, 1st STORY | Dec 4, 2023 |
| Dec 5, 2022 | C | Apt 13G · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE MAXIMUM TEMPERATURE OF 130 DEGREES AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 13G, 13th STORY, 3rd APARTMENT FROM SOUTH AT WEST | Dec 11, 2022 |
| Jun 17, 2022 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT PUBLIC HALL, 1st STORY | Jul 22, 2022 |
| Jun 17, 2022 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1st STORY | Sep 20, 2022 |
| Jun 17, 2022 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR DEFECTIVE AT PUBLIC HALL, 1st STORY | Sep 20, 2022 |
| May 19, 2021 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED TO BASEMENT AT BUILDING FRONT YARD | May 25, 2021 |
| May 19, 2021 | B | Apt 3K · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MILDEW CLOSET WEST ROOM 3 STY NORTH WEST APT 3K. , SECTION '' '' | Jun 23, 2021 |
| Dec 11, 2020 | C | § 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS AT FRONT ENTRANCE TO BUILDING , 1st STORY | Jan 6, 2021 |
| Oct 16, 2019 | B | Apt 4E · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 20, 2019 |
| Oct 16, 2019 | B | Apt 4E · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 20, 2019 |
| Oct 16, 2019 | B | Apt 8F · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SOOT ON WALLS & CLGS ENTIRE 8 STY APT 8F. , SECTION '' '' | Nov 20, 2019 |
| Oct 16, 2019 | B | Apt 4D · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 4 STY SOUTHWEST APT 4D JEFFERSON. , SECTION '' '' | Nov 20, 2019 |
| Oct 16, 2019 | C | Apt 14G · § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK ENTRANCE DOOR 14 STY NORTHWEST CENTER APT 14G. LOCATED AT APT 14G | Oct 22, 2019 |
| Oct 16, 2019 | B | D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS NORTH BULKHEAD TO ROOF. | Nov 20, 2019 |
| Oct 16, 2019 | B | D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS SOUTH BULKHEAD TO ROOF. | Nov 20, 2019 |
| Oct 16, 2019 | B | D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS BULKHEAD TO ROOF AT SOUTH PUB HALL. | Nov 20, 2019 |
| Oct 16, 2019 | B | Apt 11G · D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 11TH STY APT 11G. , SECTION '' '' | Nov 20, 2019 |
| Oct 16, 2019 | C | Apt 4C · § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK ENTRANCE DOOR TO 4 STY SOUTHEAST APT 4C. , SECTION '' '' | Oct 22, 2019 |
| Oct 16, 2019 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM 1 STY PUBLIC HALL & ON BOILER ROOM DOOR. | Oct 22, 2019 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 29, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES TO DOOR AT STAIR CASE B AT PUBLIC HALL STAIRS, 12th STORY | Open |
| Sep 29, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES TO DOOR AT BUILDING ENTRANCE AT PUBLIC HALL, 1st STORY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 1:28 PM ET. BBL 3036340001.