4 floors · 19 apartments · 16,320 sq ft · built 1922 · class C1 · owner of record: 1407 78 123 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 310 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 431 days | Next cycle year 2027 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-18 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 3, 2026 | Construction CLASS - 1 WORK WITHOUT A PERMIT. AT THE TIME OF INSPECTION, NO PERMIT WAS ON FILE FOR STRUCTURAL WORK BEING PERFORMED AT THE CELLAR LEVEL. EXISTING FLOOR JOISTS WERE OBSERVED BEING SHORED WITH ADJUSTABLE JACK POSTS, AND #39191186P | Aug 12, 2026 IN VIOLATION | $0 |
| Sep 27, 2024 | Boilers CLASS - 2 FAILURE TO FILE REQUIRED ANNUAL BOILER INSPECTION REPORTS FOR LOW-PRESSURE BOILER 30000035411Y0001 IN ACCORDANCE WITH THE RULES OF THE DEPARTMENT.1RCNY 103-01(D)(1)REQUIRES THAT AN ANNUAL INSPECTION REPORT FOR #37029300L | Jan 8, 2025 DEFAULT | $1,562 |
| Sep 27, 2024 | Boilers CLASS - 2 FAILURE TO FILE REQUIRED ANNUAL BOILER INSPECTION REPORTS FOR LOW-PRESSURE BOILER 30000035411N0002 IN ACCORDANCE WITH THE RULES OF THE DEPARTMENT.1RCNY 103-01(D)(1)REQUIRES THAT AN ANNUAL INSPECTION REPORT FOR #37029299N | Jan 8, 2025 DEFAULT | $1,562 |
| Apr 27, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING CODE COMPLIANT NOTED: AT ROOF, CRACKED AND DISPLACED FOUR SECTIONS OF CAMELBACK COPING. AT REAR EXTERIOR WALLBRICKS AND CEMENT COATING HAS BECOME LOOSE SPALLING WITH SMALL PCS MIS #35407766X | Aug 12, 2019 ADMIT/IN-VIO | $0 |
| Nov 8, 2009 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER IN THAT AT REAR OR PREMISES THERE IS AN APPROX 10'X14'SECTION OF CONCRETE RETAINING WALL THAT IS DEFECTIVE THERE ARE SEVERAL CRACKS AND G SECTION HAS COLLAPSED #34805207R | May 10, 2010 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 4, 2026 | CONSTRUCTION REQUESTING A STRUCTURAL STABILITY REPORT DUE TO STRUCTURAL WORK BEING PERFORMED AT THE CELLAR LEVEL, WHERE EXISTING FLOOR JOISTS HAVE BEEN SHORED WITH ADJUSTABLE JACK POSTS AND REINFORCED WITH SISTERED FRAMING MEMBERS. THE OBSERVED CONDITION INDICATES POTENTIAL STRUCTURAL INSTABILITY OF THE FLOOR/CE #26-01449 | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 24, 2026 | B | Apt C1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT C1, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 29, 2026 |
| Sep 24, 2026 | B | Apt C1 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIR CONDITIONER UNIT INSTALED AT FIRE ESCAPE WINDOW AT 1ST WINDOW FROM SOUTH AT WEST IN THE 3rd ROOM FROM EAST LOCATED AT APT C1, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 29, 2026 |
| Sep 21, 2026 | B | Apt C3 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOOR WITH KEY OPERATED LOCK PREVENTING ENTRANCE TO FIRE ESCAPE ROOM IN THE 2nd ROOM FROM NORTH LOCATED AT APT C3, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 26, 2026 |
| Jun 5, 2026 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GIRDERS AT BASMENT APPROX. 4 AT BASEMENT | Jun 11, 2026 |
| Jun 5, 2026 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE JOIST AT CEILING APPROX. 6 AT BASEMENT | Jun 11, 2026 |
| Jun 5, 2026 | C | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT BASEMENT AT BASEMENT | Jun 11, 2026 |
| Jun 5, 2026 | C | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRE AT CEILING THROUGH OUT AT BASEMENT | Jun 11, 2026 |
| Jun 5, 2026 | C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF 7 ILLEGAL SCREW JACKS AT BASEMENT AT BASEMENT | Jun 11, 2026 |
| Dec 11, 2024 | C | Apt C3 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT C3, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 6, 2025 |
| Dec 28, 2023 | C | Apt C2 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM EAST AT SOUTH WALL IN THE KITCHEN LOCATED AT APT C2, 3rd STORY, | Jan 21, 2024 |
| Sep 25, 2023 | B | Apt 1C · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET IN THE BATHROOM LOCATED AT APT 1C, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 30, 2023 |
| Aug 27, 2019 | C | Apt A1 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM NORTH AT EAST WALL IN THE FOYER LOCATED AT APT A1, 1st STORY, 1st APARTM | Sep 24, 2019 |
| Apr 23, 2012 | C | Apt B3 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM WEST AT NORTH WALL DOOR FRAME, 1st WINDOW FRAME FROM NORTH AT EAST WAL | May 19, 2012 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 24, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT C1, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Open |
| Sep 24, 2026 | HPD B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIR CONDITIONER UNIT INSTALED AT FIRE ESCAPE WINDOW AT 1ST WINDOW FROM SOUTH AT WEST IN THE 3rd ROOM FROM EAST LOCATED AT APT C1, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Open |
| Sep 21, 2026 | HPD B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOOR WITH KEY OPERATED LOCK PREVENTING ENTRANCE TO FIRE ESCAPE ROOM IN THE 2nd ROOM FROM NORTH LOCATED AT APT C3, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Jul 30, 2026 | HPD C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED LOCK AT DOOR LEADING TO THE ROOF (SOUTH 1) | Closed |
| Jul 30, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Closed |
| Jul 30, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 9:21 PM ET. BBL 3062450074.