Brooklyn · Block 1102 · Lot 12 · 11215

1402 8 Avenue

2 floors · 218,840 sq ft · built 1895 · class Y4 · owner of record: Nyc Department Of Homeless Services

36open violations
$3,125ECB/OATH penalties owed
0HPD class C (immediately hazardous)
66dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-11-18 (Accepted). Agency page

Dec 31, 2026
in 66 days
2 of 2 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 218,840 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1102). Agency page

Dec 31, 2032
in 2258 days
Next due 2032

Open violations

ECB / OATH (34) · $3,125 owed
IssuedViolationHearingBalance
Nov 19, 2025Elevators CLASS - 2
CLASS 2: MISSI NG MAINTENANCE RECORD FOR OCTOBER 2025, CONDUCT ROUTINE SERVICE AND UPDATE THE RECORDS
#39167576K
Dec 23, 2025
POP/IN-VIO
$0
Nov 19, 2025Elevators CLASS - 2
CLASS 2. TWO DIFFERENT CAPACITY NUMBERS SHOWN ON THE TAGS ON THE PLATFORM, PROVIDE CORRECT NUMBER, REMOVE A WRONG ONE. STAIR LIFT COULD NOT BE OPERATED DURING INSPECTION. NO BUILDING PERSONNEL WERE ABLE TO DEMO
#39167575Z
Dec 23, 2025
POP/IN-VIO
$0
Nov 19, 2025Construction CLASS - 2
OBSERVED THROUGHOUT THE BUILDING SPRINKLER HEADS OBSTRUCTED. IN BASEMENT LACK SUPPORT ON SPRINKLER LINE, USING SHARK BITE FITTINGS ON WATER LINES, JIM CAPS ON WASTE LINES, GAS LINES AND SPRINKLER LINES CORRODED
#39167589J
Dec 23, 2025
POP/IN-VIO
$0
Nov 19, 2025Construction CLASS - 1
WORK WITHOUT A PERMIT. PARTITION WALL ERECTED WITHOUT PERMITS ON FILE, OBTAIN PERMIT
#39167598L
Dec 23, 2025
POP/IN-VIO
$0
Nov 19, 2025Elevators CLASS - 2
CLASS 2: EMERGENCY PHONE INOPERATIVE - RESPONDING SIDE UNABLE TO HEAR PERSON IN THE CAR, PROVIDE CLEAR 2 WAY COMMUNICATION.
#39167574R
Dec 23, 2025
POP/IN-VIO
$0
Nov 19, 2025Construction CLASS - 1
FAILURE TO SAFEGUARD THE PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. PARTITION WALL ERECTED OBSTRUCTING EGRESS ON GROUND FLOOR LEVEL. NO PERMITS ON FILE, SAFEGUARD PUBLIC AND PROPERTY
#39167599N
Dec 23, 2025
POP/IN-VIO
$0
Nov 19, 2025Boilers CLASS - 2
FEDERAL BOILER MODEL# FST-500. MISSING BODY DRAINS ON RELIEF VALVES, MISSING SIGHT GLASS AND HOLDER ON REAR DOOR. CORRECT VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION.
#39167568K
Dec 23, 2025
POP/IN-VIO
$0
Apr 3, 2025Boilers CLASS - 2
#2 FEDERAL STEAM BOILER IS MISSING REAR FLAME SIGHT GLASS+SAFETY VALVES MISSING BODY DRAIN DISCHARGE PIPES+COMBUSTION AIR FAN MISSING AIR PROVING SWITCHES+COMBUSTION AIR FAN HAS WORN BEARINGSÝNOISE+VIBRATION¨+C
#39143804R
Apr 10, 2025
POP/IN-VIO
$0
Mar 22, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 35657506L ISSUED ON 04/25/2023 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. (FAILU
#39109592P
May 29, 2024
POP/IN-VIO
$0
Mar 22, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 35657505J ISSUED ON 04/25/2023 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. (FAILU
#39109596M
May 29, 2024
POP/IN-VIO
$0
Feb 6, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS AS STATED IN ECB #35657506L ISSUED ON 04/25/2023 AND FILE A CERTIFICATE OF CORRECTION AS PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH COMMISSIO
#39105305P
Apr 27, 2024
POP/IN-VIO
$0
Feb 6, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS AS STATED IN ECB #35657505J ISSUED ON 04/25/2023 AND FILE A CERTIFICATE OF CORRECTION AS PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH COMMISSIO
#39105303L
Apr 27, 2024
POP/IN-VIO
$0
Nov 2, 2023Unknown CLASS - 2
I OBSERVED AT THE ENTRANCE TO THE BOILER ROOM THE LACK OF LIGHTING/ILLUMINATION REQUIRED AT POINTS OF EGRESS., COMPLY WITH EC; PROVIDE/MAINTAIN ILLUMINATION.
#39098632J
Nov 15, 2023
POP/IN-VIO
$0
Nov 2, 2023Construction CLASS - 2
HOLE PENETRATIONS ON THE WALL AND CEILING OF THE CELLAR LEVEL AND NO FIRE STOPPING AROUND PIPING., REPAIR AND/OR REPLACE
#39098620M
Nov 14, 2023
POP/IN-VIO
$0
Oct 11, 2023Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION 04252023COBMEJ01, DATED 4/25/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS OF 10/
#37025665X
Jan 23, 2024
POP/IN-VIO
$0
Oct 11, 2023Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION 04252023COBMEJ01, DATED 4/25/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS OF 10/
#37025666H
Jan 23, 2024
POP/IN-VIO
$0
Jul 10, 2023Construction CLASS - 2
TWO STORY BUILDING OBSERVED ON THE 14TH SIDE OF BUILDING TWO STEPPING CRACKS ONE IS APPROX. 10 FEET AND 4 FEET, JUST WEST OF ENTRANCE TO BUILDING AND ALONG PEDESTRIAN WALKWAY., REPAIR AND/OR REPLACE
#39089984Z
Jul 29, 2023
POP/IN-VIO
$0
Apr 25, 2023Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING WALLS AND/OR APPURTENANCES. NOTE:OBSERVEDIN SEVERAL PLACES AROUND THE EXTERIOR OF THE BLDG,RUNNING CRACKS IN FACADE,AREAS WHERE THE BROWNSTONE HAS BROKEN OFF AND FALLEN,AND SECTION
#35657505J
Sep 6, 2023
POP/IN-VIO
$0
Apr 25, 2023Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTE:OBSERVED IN YMCA,AREAS OF THE FLOOR ARE SINKING AND CRACKED AND CLOSED OFF FROM USE,AND IN THE AREA OF THE CELLAR UNDER THE ATHLETIC FIELD. THERE ARE
#35657506L
Sep 6, 2023
POP/IN-VIO
$0
Mar 21, 2023Construction CLASS - 2
-CRACKS ON THE PARAPET AND DORMITORY STRUCTURE WALLS ON ROOF. (VOILATION NO.39062303Y- DATE: 05/17/2022)., REPAIR AND/OR REPLACE; REPAIR AND OR REPLACE
#39082168Z
Mar 27, 2023
POP/IN-VIO
$0
Mar 21, 2023Construction CLASS - 2
-FIRESTOP NEEDED IN MULTIPLE ROOMS ON CEILING OF 3RD FLOOR AND EMERGENCY DOORS PASSAGEWAYS ALSO LEADING TO THE ROOF., PROVIDE/MAINTAIN FIRE STOPPING; PROVIDE/MAINTAIN FIRE STOPPING
#39082166P
Mar 27, 2023
POP/IN-VIO
$0
Mar 21, 2023Construction CLASS - 2
-PARTICAL BOARD SHEETHING INSTALLED IN 3RD FLOOR CORRIDOR/HALLWAY LEADING TO ROOF COVERING EXITING FIRE RATED WALLS., MAINTAIN EXTERIOR BUILDING WALL; REPAIR WALL PROPERLY
#39082170H
Mar 27, 2023
POP/IN-VIO
$0
Mar 21, 2023Construction CLASS - 2
BOTH EMERGENCY DOORS FOR THE ROOF AND GROUND LEVEL DO NOT SELF CLOSE., REPAIR AND/OR REPLACE; REPAIR AND OR REPLACE
#39082171J
Mar 27, 2023
DEFAULT
$3,125
Mar 21, 2023Construction CLASS - 2
-SLIDING BOLT LOCKS ILLEGALLY INSTALLED ON DORMITORY DOORS. (VIOLATION NO.39062306J - DATE; 05/17/2022., PROVIDE LEGAL HARDWARE; PROVIDE LEGAL HARDWARE
#39082167R
Mar 27, 2023
POP/IN-VIO
$0
Feb 7, 2023Boilers CLASS - 2
BODY DRAIN PIPES MISSING AT SAFETY RELIEF VALVES, KING VALVE LEAKING ONTO BOILER, FRESH AIR FAN OUTSIDE LOUVER PARTIALLY CLOGGED/ FAN MISSING AIR PROVING SWITCH INTERLOCKED WITH 2 BOILERS + 4 HWH'S, CORRECT ALL
#39079222N
Feb 27, 2023
POP/IN-VIO
$0
Jul 25, 2022Boilers CLASS - 2
BODY DRAIN PIPES MISSING AT SAFETY VALVES/KING VALVE LEAKING ONTO BOILER/FRESH AIR FAN OUTSIDE LOUVER 1/2 CLOGGED/FAN MISSING AIR PROVING SWITCH INTERLOCKED WITH 2 BOILERS+4 HWH'S;CORRECT VIOLATION AND SUBMIT T
#39066611Y
Jul 27, 2022
POP/IN-VIO
$0
May 17, 2022Construction CLASS - 2
NOTED: OBSERVED AT CELLAR'S ELECTRICAL ROOM, PIPES AND CONDUITS PENETRATING THROUGH WALLS INTO ADJACENT AREAS WITH NO FIRE STOPPING PROVIDED., PROVIDE/MAINTAIN FIRE STOPPING
#39062302M
Jun 7, 2022
POP/IN-VIO
$0
May 17, 2022Construction CLASS - 2
NOTED: OBSERVED AT CELLAR'S GAS METER ROOM, WATER METER AREAS EXPOSED DECKING AND STEEL BEAMS WITH NO FIREPROOFING PROVIDED., REPAIR AND/OR REPLACE
#39062304X
Jun 7, 2022
POP/IN-VIO
$0
May 17, 2022Construction CLASS - 2
NOTED: FIREPROOF SELF CLOSING DORMITORY AND OFFICE DOORS ARE NOT SELF CLOSING, DOORS REMAIN IN AN OPEN POSITION WHEN OPENED., REPAIR AND/OR REPLACE
#39062307L
Jun 7, 2022
POP/IN-VIO
$0
May 17, 2022Construction CLASS - 2
NOTED: OBSERVED HORIZONTAL AND VERTICAL CRACKS THROUGH BRICKS AT NORTH AND SOUTH ELEVATION, MISSING BRICK MORTAR AT VARIOUS LOCATIONS THROUGHOUT EXTERIOR WALLS., MAINTAIN EXTERIOR BUILDING WALL
#39062303Y
Jun 7, 2022
POP/IN-VIO
$0
May 17, 2022Construction CLASS - 2
NOTED: OBSERVED AT 2ND FLOOR, ILLEGAL SLIDE BOLT WITH LOCKS INSTALLED ON ALL DORMITORY DOORS., PROVIDE LEGAL HARDWARE
#39062306J
Jun 7, 2022
POP/IN-VIO
$0
Feb 24, 2020Construction CLASS - 2
NOTED: OBSERVED AT EXPOSURE #2 (SOUTH ELEVATION) AND EXPOSURE #4 (NORTH ELEVATION), VERTICAL AND HORIZONTAL CRACKS THROUGH BRICKS AT VARIOUS LOCATIONS, HOLE IN BRICK AT EXP.#2 AND #4, MISSING BRICK JOINT MORTAR
#39018191K
Mar 16, 2020
POP/IN-VIO
$0
Jul 28, 2017Unknown CLASS - 2
ELECTRICAL WORK W/O A PERMIT. OBSERVED 4 HVAC SYSTEMS WITH SERVICE SWITCHES & A GFCL RECEPTUCLE OUTLET INSTALLED & WIRED ON ROOF TOP AREA. THIS WORK ISN'T COVERED UNDER ANY PREVIOUS ELECTRICAL APPL. REMEDY: COM
#35287441Y
Oct 16, 2017
POP/IN-VIO
$0
Jul 28, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTE: @ BOILER ROOMFIRE PROOFING IS MISSING FROM STEEL, NEW STEEL DECK NO FIRE PROOFING DONE. REMEDY: REPAIR &/OR REPLACE.
#35272568J
Oct 16, 2017
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (2)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Report
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 7:12 AM ET. BBL 3011020012.

Look up another building