Brooklyn · Block 4452 · Lot 25 · 11239

1400 Pennsylvania Avenue

4 floors · 187,283 sq ft · built 1974 · class W1 · owner of record: Nyc Department Of Education

23open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
165dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 187,283 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 165 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 165 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1140 days
Next cycle year 2029
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 4452). Agency page

Dec 31, 2032
in 2236 days
Next due 2032
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-18 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (8)
IssuedViolationHearingBalance
Apr 30, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-542.NOTED:AT 3RD FL GYM RM 317 NOT INSTALLED/PROVIDED WITH EMERGE
#35732775R
Jun 3, 2026
POP/IN-VIO
$0
Apr 30, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:AT 1ST FL GYM,AUDITORIUM,CAFETERIA EMERGENCY LIGHTS NOT WORKING WHEN T
#35732776Z
Jun 1, 2026
POP/IN-VIO
$0
Apr 30, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.USE OF PROHIBITED DOOR AND/OR HARDWARE BC 1008.1.8;27-371(J).NOTED:AT 2ND FL AND 1ST FL HALLWAYS SMOKE DOORS INSTALLED/USED KICK/HOOK DOOR STOPPERS.REM:PROV
#35732777K
Jun 1, 2026
POP/IN-VIO
$0
Apr 30, 2026Construction CLASS - 2
REISSUE ECB#35721274P FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT 4TH FL RM 430B 1ST FL EXIT 8 DOOR/FRAME IN DISREPAIR RUSTED.REM:REPAIR AND/OR REPLACE.
#35722472K
Jun 1, 2026
POP/IN-VIO
$0
Apr 30, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT 3RD FL STAIR D 2ND FL HALLWAY SMOKE DOOR HANDLES INDISREPAIR/MISSING/NONE.REMREPAIR AND/OR REPLACE.
#35732778M
Jun 1, 2026
POP/IN-VIO
$0
Apr 30, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMLIANT MANNER.NOTED:AT 4TH FL HALLWAY SMOKE DOOR NEAR RM 434 MISSING/NONE GLASS PANEL.REM:REPAIR AND/OR REPLACE.
#35722473M
Jun 3, 2026
POP/IN-VIO
$0
Apr 30, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT 4TH FL HALLWAY SMOKE DOORS NEAR RM STAIR B/401,407 3RD FL HALLWAY SMOKE DOOR NEAR RM 327,334 2ND FL HALLWAY SMOKE DOORS NEAR RM STAIR B/201,207 1ST
#35722474Y
Jun 3, 2026
POP/IN-VIO
$0
Jul 21, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ROOM 430B DOOR BROKEN WEIDS BRAKE FRAME CRACKED EXTERIOR DOOR FRAME BROKEN AND RUSTED AT BASE OF FRAMES EXIT 8,1ST FLOOR B EXTERIOR DOORS BASE OF FRAME RUST
#35721274P
Sep 3, 2025
POP/IN-VIO
$0
DOB (5)
IssuedViolationStatus
Nov 19, 2020ELEVATOR

#9027/690510
DOB VIOLATION - ACTIVE
Oct 28, 2019ELEVATOR

#9027/663199
DOB VIOLATION - ACTIVE
Jun 1, 2016NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST
FAILURE TO PERFORM CATEGORY 5 INSPECTION
#03013
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#23820
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#23821
DOB VIOLATION - ACTIVE
DOB NOW Safety (10)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Aug 25, 2023Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Report
Active
Jun 1, 2016Elevators EVCAT5
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 2:43 PM ET. BBL 3044520025.