Queens · Block 5180 · Lot 38 · 11355

140-42 Sanford Avenue

8 floors · 34 apartments · 14,868 sq ft · built 2022 · class D6 · owner of record: Blackdragon Sanford Llc

21open violations
$169,926ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 43 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 59 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page

Feb 21, 2028
in 460 days
No Cycle 10 report on record yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1139 days
Next cycle year 2029

Open violations

ECB / OATH (44) · $169,926 owed
IssuedViolationHearingBalance
Oct 24, 2026Construction CLASS - 1
ATOI, I OBSERVED THAT WORK WAS CONTINUED WHILE SWO #4A52660 EXISTS HERE SINCE 09/24/26 - INDICATING NO OTHER EXTERIOR WORK ALLOWED AT EXP #3. I OBSERVED WORKERS WERE ON 7-8FL SCAFFOLD ON EXP #3, PERFORMING EXTE
#39561008H
Dec 29, 2026
PENDING
$10,000
Oct 24, 2026Construction CLASS - 2
OBSERVED SATURDAY 10/24/26 AFTER-HOUR VARIANCE PERMIT OBTAINED, BUT FORBADE ANY SCAFFOLD USE, EXTERIOR WORK OR WORK ABOVE 75FT. OBSERVED EXP #3 REAR YARD, WORKERS WERE ON 7-8 FLOOR SUPPORTED SCAFFOLD PERFORMING
#39561012K
Dec 29, 2026
PENDING
$1,250
Oct 24, 2026Construction CLASS - 2
ATOI, OBSERVED WORKERS IN THE LOBBY. CALLED OUT BUT ACCESS FOR INSPECTION WAS DENIED. WORKERS THEN WENT ON 8FL SCAFFOLD ON EXP #3 AND STARTED WORKING. INSPECTION DENIED PUT SAFETY STANDARDS AT RISK FOR EVERYONE
#39561005M
Dec 29, 2026
PENDING
$2,500
Sep 27, 2026Unknown CLASS - 2
MISCELLANEOUS VIOLATIONS.BC 3303.3 ATOI OF 8 STORY BUILDING AT ROOF LEVEL APPROX.27,653 SQ FT SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITY.UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR TO ALER
#39559839X
Dec 1, 2026
PENDING
$2,500
Sep 24, 2026Unknown CLASS - 1
BC3314.1 SUPPORTED SCAFFOLD.@8STORY NB SITE OBSERVE UNSAFE SUPPORTED SCAFFOLD UP TO ROOF LEVEL@ALL EXPOSURES CREATING FAILURE/DISLODGEMENT HAZARDS AFFECTING HEALTH&LIFE SAFETY:NOT MAINTAINED&MISSING DEBRIS NET+
#39559605N
Dec 1, 2026
PENDING
$10,000
Sep 24, 2026Unknown CLASS - 2
@8STORY NB SITE IN EXTERIOR PHASE W/UNSAFE SUPPORTED SCAFFOLD UP TO ROOF LEVEL TOWERING OVER ADJOIN PROPERTY 42-08 UNION STREET WITH NO PROTECTION OF ROOF IN PLACE TO CODE BC3309.10 NOR ENGINEERED ENCLOSURE SYS
#39559606P
Dec 1, 2026
PENDING
$2,500
Jul 28, 2026Unknown CLASS - 2
BC 3314.1 AT TIME OF INSPECTION OBSERVED WORKER AT ROOF LEVEL WORKING ON A SUPPORTED SCAFFOLD NOT IN THE STATE OF READINESS, NO TOEBOARDS, NO PLANKS TIED DOWN OR GUARDRAIL SYSTEM AS REQUIRED IN 3314.5, 3314.5.5
#39557172H
Dec 29, 2026
$2,500
Jul 28, 2026Construction CLASS - 2
OBSERVED VEHICLE EXITING THE SITE AT VEHICULAR ACCESS POINT NOT CLEARLY MARKED WITH HI VISIBILITY OR ADDITIONAL SUPPORT AT VERTICAL MEMBERS CREATING HAZARDOUS CONDITIONS TO THE STRUCTURAL STABILITY OF THE SHED
#39557173J
Dec 29, 2026
$2,400
Jul 17, 2026Construction CLASS - 1
OBSERVED: ACTIVE SITE CP PRESENT UPON INSPECTION NOTED FAILURE TO MAINTAIN HOUSEKEEPING,CARDBOARD, CEMENT AND DEBRIS MATERIALS IT NOTED IN DIFERENT LEVEL AND LOCATIONS CREATING HAZARDS CONDITION FOR WORKERS ON
#39556769X
Dec 1, 2026
$2,500
Jun 12, 2026Unknown CLASS - 2
6/11/2026 6:41PM WHILE PERFORMING A SEVERE WEATHER ADVISORY INSPECTION OBSERVED AN 8 STORY RESIDENTIAL BUILDING W/ NO CONSTRUCTION ACTIVITY UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR TO ALERT WAT
#39555512X
Mar 9, 2027
PENDING
$2,500
May 19, 2026Unknown CLASS - 1
AT THE TIME OF INSPECTION OF AN 8-STORY ACTIVE JOB SITE UNDERGOING STUCCO AND STYROFOAM OPERATIONS, STYROFOAM RESIDUE WAS OBSERVED ON THE ADJACENT PROPERTY AT EXP# 4 AND ON EQUIPMENT, CREATING A HAZARDOUS CONDI
#39554283R
Feb 2, 2027
$10,000
May 19, 2026Construction CLASS - 2
BC3307.6.4.10 AT THE TIME OF INSPECTION OF AN 8-STORY ACTIVE JOB SITE, THE SIDEWALK SHED AT EXP# 1 AND 2 WAS OBSERVED NOT MAINTAINED, WITH DETERIORATED MODSEAL THROUGHOUT THE STRUCTURE, CREATING A HAZARDOUS CO
#39554284Z
Feb 2, 2027
$2,400
Feb 25, 2026Unknown CLASS - 2
3314.3PIPE SCAFFOLDS CONTRARY TO PLANS &UNSAFE.EXPO1 TRUSS INSTALLED AT 2FLR LEVEL ON SF NOT SHOWN ON PLANS.SF @EXPO1 IS 2 LAYERS: 1 5FT SECTION & 1 3FT SECTION, THIS NOT SHOWN ON PLANS.AT ENDS OF SF @EXPO1 LAR
#39550927P
Jan 5, 2027
$2,500
Feb 25, 2026Construction CLASS - 1
ALTERNATE METHODS OF PROTECTION FOR ADJOINING PROPERTIES ARE CONTRARY TO SSP. OBS PIPESCAFFOLD INSTALLED @EXPOS 1,2,3 NOT SHOWN ON SSP PROVIDED. HOIST BEING INSTALLED @EXPO3 NOT SHOWN ON SSP. NEEDLEBEAMS INSTAL
#39550925L
Jan 5, 2027
$2,500
Feb 25, 2026Unknown CLASS - 2
3301.13.7OBS MULTPL UNSAFE & HAZARDOUS CONDITIONS; CS DAILY LOG DOES NOT CONTAIN: SAFEGUARDS FOR ADJACENT PROPERTIES & TEMP EQUIP CONTRARY SSP, SSP NOT REFLECTING FIELD CONDITIONS, ACTIVE WORK ON FLRS W/ ICE&SN
#39550929Z
Jan 5, 2027
$2,500
Feb 25, 2026Unknown CLASS - 1
3301.5UNSAFE CONDITIONS. ACTIVE WORK ON FLRS NOT CLEARED OF ICE&SNOW. FLOORS/STAIRS ARE ICY/SNOWY, CREATE FALL HZRDS FOR ALL. 3308.7ON MULTIPLE FLOORS & ELEVATOR SHAFT EDGES INADEQUATE GUARDRAILS; MISSING TOEBO
#39550926N
Jan 5, 2027
$5,000
Jan 31, 2026Unknown CLASS - 1
OBSERVED SUPPORTED SCAFFOLD EXP #1 NETTING LOOSE, EXP #3 HAD LOOSE ITEM DANGLING OUTSIDE, CREATING HAZARDS TO PEDESTRIANS AND ADJACENT PROPERTY (BC 3314.1). STOP EXTERIOR WORK AND USE OF SCAFFOLD ON EXP #1 AND
#39549821Z
Nov 10, 2026
IN VIOLATION
$5,000
Jan 19, 2026Construction CLASS - 1
BC 3303.4.2 (4.). OBSERVED SITE DEBRIS CONTAINER ON STREET FILLED TO THE BRIM & NOT COVERED CREATING HAZARDS OF STRUCK-BY&DISLODGEMENT TO THE PUBLIC/PEDESTRIAN AFFECTING ALL HEALTH & LIFE SAFETY. PROVIDE DEBR
#39549309J
Oct 6, 2026
IN VIOLATION
$2,500
Jan 19, 2026Unknown CLASS - 2
BC 3307.2.1 OBSTRUCTION OF STREETS. AT PERMITTED ACTIVE SITE OBSERVED SITES DEBRIS CONTAINER FRONT OF SITES OBSTRUCTING STREET,& VERIFIED PER RECORDS, SITE FAILED TO OBTAIN DEPARTMENT OF TRANSPORTATION PERMIT
#39549308H
Oct 6, 2026
IN VIOLATION
$2,500
Jan 19, 2026Site Safety CLASS - 1
@ACTIVE NB SITE WITH SUPERINTENDENT ON PERMIT I REQUESTED ONSITE PERSONNEL FOR SITE SAFETY PLAN WHICH WASN'T PROVIDED TO ENSURE SOUND CONSTRUCTION OF SIDEWALK SHEDS, PROPER SAFETY MEASURES, AND SAFE CONSTRUCTIO
#39549311Z
Oct 6, 2026
IN VIOLATION
$2,500
Jan 19, 2026Unknown CLASS - 1
BC3303.12 INOPERABLE FDNY TEMPORARY HOIST/ELEVATOR.@8 STORY NB SITE UP TO ROOF LEVEL OBSERVE ACTIVE WORK THROUGHOUT SITE & ABOVE 7TH FL & OVER 75FT IN HEIGHT W/ FDNY TEMPORARY HOIST/ELEVATOR NOT IN STATE OF REA
#39549310R
Oct 6, 2026
IN VIOLATION
$5,000
Jan 19, 2026Unknown CLASS - 2
BC 3307.4.7 NO WORK OR STORAGE ZONE BARRIER. OBSERVE SITES DEBRIS CONTAINER FILLED TO THE BRIM ADJACENT TO SITES SIDEWALK SHED& NO PROTECTIVE BARRIER IN PLACE FOR PEDESTRIAN TO BC3307.4.7 SECTION .3 TO PREVENT
#39549307X
Oct 6, 2026
IN VIOLATION
$2,500
Apr 8, 2025Construction CLASS - 2
JOB FENCE JOB#Q00220245 PERMIT EXPIRED ON 10/10/2022.@INACTIVE EXPIRED PERMIT 8STORY NB SITE OBSERVE JOB FENCE IN PLACE AT EXP#1 ADJACENT TO SIDEWALK AND I VERIFIED PER DEPARTMENTS RECORDS, THE JOB FENCE JOB#Q0
#39538881R
Jun 17, 2025
DEFAULT
$3,125
Apr 8, 2025Unknown CLASS - 2
SIDEWALK SHED JOB#Q00516824 PERMIT EXPIRED ON 11/03/2023.@INACTIVE EXPIRED PERMIT 8STORY NB SITE OBSERVE SIDEWALK SHED IN PLACE AT EXP#1 COVERING SIDEWALK AND I VERIFIED PER DEPARTMENTS RECORDS, THE SIDEWALK SH
#39538882Z
Jun 17, 2025
DEFAULT
$3,125
Apr 3, 2025Unknown CLASS - 1
BC 3314.1 SCOPE SCAFFOLD: DURING INSPECTION OF AN INACTIVE SITE, I OBSERVED THAT THE SUPPORTED SCAFFOLD IN PLACE WAS MISSING DEBRIS NETTING, THE NETTING WAS DISLODGED, THE PLANKS WERE NOT TIED DOWN. THE LACK OF
#39538751Z
Nov 16, 2026
IN VIOLATION
$2,500
Apr 3, 2025Construction CLASS - 2
DURING INSPECTING OF A NONE ACTIVE SITE I OBSERVED THAT THE SUPPORTED SCAFFOLD IN PLACE HAD AN EXPIRED PERMIT JUNE 26, 2024 Q00893125-I1-SF WITH NO RENEWAL IN PROCESS DOB SYSTEM. ALL PERMITS MUST BE VALID AND M
#39538750R
Nov 16, 2026
IN VIOLATION
$1,250
Feb 6, 2025Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT/INSTALLATION ON SITE EXPIRED PERMIT. AS NOTED: AT TIME OF INSPECTION ON A CONSTRUCTION SITE OF A PROPOSED 7STORY, BUILDING WAS CLOSED, OBSERVED CONSTRUCTION FENCE PERMIT HAD EXP
#35689171P
Feb 25, 2027
DEFAULT
$3,125
Feb 6, 2025Unknown CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT/INSTALLATION ON SITE EXPIRED PERMIT "SIDEWALK SHED". AS NOTED: AT TIME OF INSPECTION ON A CONSTRUCTION SITEOF A PROPOSED 7 STORY BUILDING WAS CLOSED. OBSERVED CONSTRUCTION SIDEW
#35689172R
Feb 25, 2027
DEFAULT
$3,125
Sep 27, 2023Construction CLASS - 2
AT TIME OF INSPECTION NO COMPETENT PERSON, OR ANYONE IN CHARGE ON SITE. ONLY 2 WORKERS THAT DID NOT SPEAK ENGLISH ON SITE. SIGNALED WORKER TO CALL "BOSS". WAITED 15 MINUTES, NO ONE SHOWED., PROVIDE APPROVED /AC
#39095856P
May 28, 2024
IN VIOLATION
$1
Jun 26, 2023Construction CLASS - 2
NO EN DRAWING AND COM/CKHECK APPROVED FROM DOB PROVIDED ON THE JOB SITE AT THE TIME AT THE TIME OF INSPECTION., PROVIDE APPROVED /ACCEPTED CONSTRUCTION DOCUMENTS; PLEASE GO TO HTTPS://WWW1.NYC.GOV/SITE/BUILDING
#39089113N
Nov 12, 2024
IN VIOLATION
$625
Jun 20, 2023Construction CLASS - 2
I OBSERVED A SIDEWALK SHED/OVER HEAD PROTECTION INSTALLED AT EXPOSURES 1,3 & 4 WITH SCAFFOLD INSTALLED ON TOP APPROX. 48 FT AT EXPOS 2 & 4.AFTER REQUESTING TO SEE APPROVED SCAFFOLD DRAWINGS AS WELL AS 6 MONTHS
#39517984R
Aug 29, 2023
DEFAULT
$3,125
Jun 20, 2023Construction CLASS - 1
AT THE TIME OF MY INSPECTION OF A ACTIVE PROPOSED 8 STORY CONSTRUCTION SITE I OBSERVED SCAFFOLD BEING INSTALLED AT APPROX. 60 FEET IN HEIGHT AT EXPOSURE 3 & 4. UPON REVIEW OF DOB RECORDS THERE WAS NO ACTIVE PER
#39517982N
Aug 29, 2023
DEFAULT
$12,500
Jun 20, 2023Construction CLASS - 2
AT THE TIME OF MY INSPECTION OF A ACTIVE PROPOSED 8 STORY CONSTRUCTION SITE I OBSERVED A ROOF UNPROTECTED AT EXPOSURE 3. UPON REVIEW OF THE APPROVED SSP ROOF PROTECTION( FOAM & WOOD) SHOULD OF BEEN PROVIDED AT
#39517990N
Aug 29, 2023
DEFAULT
$3,125
Jul 5, 2022Construction CLASS - 1
NO ROOF PROTECTION IN PLACE TO CODE BC3309.10.ON 8 STORY NB SITE UP TO 4TH FLOOR OBSERVE EXPOSURE2 ADJOINING PROPERTY'S ROOF HAVE CONCRETE DEBRIS AND MISSING PROTECTIONS TO CODE BC3309.10 WHILE SITE CONTINUES C
#39503033Y
Mar 2, 2023
IN VIOLATION
$2,500
Jul 5, 2022Construction CLASS - 1
WORK NOT ADHERE TO SITE SAFETY PLAN.ON 8 STORY NB SITE UP TO 4TH FLOOR OBSERVE EXPOSURE2 ADJOINING PROPERTY MISSING SECTION OF OVERHEAD PROTECTION AND OCCUPANT IS NEAR BELOW THE SITE AND AFTER REVIEWING THE PRO
#39503032M
Mar 2, 2023
IN VIOLATION
$2,500
May 14, 2022Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT EXPIRED PERMIT.NOTE:AT THE TIME OF INSPECTION OBSERVED A HEAVY DUTY SIDEWALK SHED AT EXPOSURE ONE WITH PERMIT#Q00516824-SH.PEDESTRIAN WALKING UNDER THIS SIDEWALK SHED.ALSO OBSER
#35639224Y
Sep 6, 2022
IN VIOLATION
$625
Feb 4, 2022Construction CLASS - 2
CONSTRUCTION SITE JOB FENCE PERMIT EXPIRED ON 01-13-2022 #Q00220245.ATTIME OF INSPECTION ON AN ACTIVE 8 STORY NB PERMIT SITE IN SOE/FOUNDATION PHASE I OBSERVED JOB FENCE IN PLACE WHERE REQUIRED & UPON RESEARCH
#35639534J
May 3, 2022
IN VIOLATION
$625
Jan 21, 2022Construction CLASS - 1
JOB FENCE NOT CONSTRUCTED/MAINTAINED PER CODE EXPOSING ADJOINING PROPERTY OCCUPANTS AT EXP.#4 140-40 SANFORD AVE TO FALL HAZARD OVER 6 FT INTO SITE.AT TIME OF INSPECTION IN RESPONSE TO COMPLAINT I OBSERVED INAC
#35641290P
Apr 19, 2022
DEFAULT
$12,500
Jan 6, 2022Construction CLASS - 1
DURING EXCAVATION WORK IN PROGRESS AT EXPOSURE 2, EXISTING FOUNDATION WALL OF ADJACENT PROPERTY 42-04 UNION ST. EARTHWORK HAS PUNCTURED FOUNDATION WALL AND CREATED LARGE VERTICAL CRACK., SAFEGUARD PUBLIC AND PR
#39053908M
Sep 13, 2022
IN VIOLATION
$10,000
Jan 5, 2022Construction CLASS - 1
FAILURE TO OBTAIN REGISTERED DESIGN PROFESSIONAL EVALUATION PRIOR TO USING EXISTING STRUCTURE(ADJOINING PROPERTIES FOUNDATION WALLS)TO SUPPORT SITES CONCRETE FOUNDATION CONSTRUCTION.AT TIME OF INSPECTION ON A A
#35641141L
Apr 12, 2022
DEFAULT
$12,500
Jan 5, 2022Construction CLASS - 1
BC 3304.7 FAILURE TO MAINTAIN EXCAVATION SAFE MEANS OF INGRESS AND EGRESS FOR SITE PERSONNEL AND PUBLIC.AT TIME OF INSPECTION ON A ACTIVE 8 STORY NEW BUILDING SITE IN EXCAVATION & FOUNDATION PHASE I OBSERVED WO
#35641140J
Apr 12, 2022
DEFAULT
$6,250
Dec 2, 2021Construction CLASS - 2
JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION.NOTE:AT TIME OF INSPECTION OF 8 STORY BUILDING AT EXCAVATION LEVEL UNDER CONSTRUCTION OBSERVED EXCAVATION AND SITE DRILLING/BORED WITH TEMPORA
#35632576X
Aug 16, 2022
IN VIOLATION
$500
Dec 2, 2021Construction CLASS - 2
FAILURE TO SAFETY EQUIPMENT MEASURE.NOTE:AT TIME OF INSPECTION OF 8 STORY BUILDING AT EXCAVATOIN LEVEL UNDER CONSTRUCTION OBSERVED RITE BOURED AT EXP #3 VERY CLOSE TO ADJACENT PROPERTY AND DAMAGE ADJACENT PROPE
#35632577H
Aug 16, 2022
IN VIOLATION
$2,500
Jul 8, 2020Construction CLASS - 2
FORMS FILED WITH DEPT.OF BUILDINGS DO NOT HAVE REQUIRED SIGNATURES.AS NOTED:AT TIME OF INSPECTION CONSTRUCTION SITE WAS CLOSED.OBSERVED 8 STORY CONCRETE CAST-IN PLACE NEW BUILDING AT FLOOR#4 SLAB LEVEL.TR-3 TEC
#35651323L
Oct 4, 2022
IN VIOLATION
$250
DOB (0)

None open.

DOB NOW Safety (12)
IssuedViolationStatus
Oct 28, 2026AEUHAZ FTC-AEU-HAZ
Active
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 7)
Active
Feb 22, 2024Benchmarking - LL84 FTF-EN-BENCH
Active
Feb 22, 2024Benchmarking - LL84 FTF-EN-BENCH
Active
Dec 1, 2023Energy Grade - LL33 FTP-EN-EGRDEA
Active
Dec 1, 2023Energy Grade - LL33 FTP-EN-EGRDEA
Active
Nov 2, 2023Benchmarking - LL84 FTF-EN-BENCH
Active
Nov 2, 2023Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2023Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2023Benchmarking - LL84 FTF-EN-BENCH
Active
May 2, 2023Benchmarking - LL84 FTF-EN-BENCH
Active
May 2, 2023Benchmarking - LL84 FTF-EN-BENCH
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 28, 2026DOB SafetyAEUHAZ: Open
Oct 24, 2026ECBConstruction: ATOI, I OBSERVED THAT WORK WAS CONTINUED WHILE SWO #4A52660 EXISTS HERE SINCE 09/24/26 - INDICATING NO OTHER EXTERIOR WORK ALLOWED AT EXP #3. I OBSERVED WORKERS WERE ON 7-8FL SCAFFOLD ON EXP #3, PERFORMING EXTEOpen
Oct 24, 2026ECBConstruction: OBSERVED SATURDAY 10/24/26 AFTER-HOUR VARIANCE PERMIT OBTAINED, BUT FORBADE ANY SCAFFOLD USE, EXTERIOR WORK OR WORK ABOVE 75FT. OBSERVED EXP #3 REAR YARD, WORKERS WERE ON 7-8 FLOOR SUPPORTED SCAFFOLD PERFORMINGOpen
Oct 24, 2026ECBConstruction: ATOI, OBSERVED WORKERS IN THE LOBBY. CALLED OUT BUT ACCESS FOR INSPECTION WAS DENIED. WORKERS THEN WENT ON 8FL SCAFFOLD ON EXP #3 AND STARTED WORKING. INSPECTION DENIED PUT SAFETY STANDARDS AT RISK FOR EVERYONEOpen
Sep 27, 2026ECBUnknown: MISCELLANEOUS VIOLATIONS.BC 3303.3 ATOI OF 8 STORY BUILDING AT ROOF LEVEL APPROX.27,653 SQ FT SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITY.UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR TO ALEROpen
Sep 24, 2026ECBUnknown: BC3314.1 SUPPORTED SCAFFOLD.@8STORY NB SITE OBSERVE UNSAFE SUPPORTED SCAFFOLD UP TO ROOF LEVEL@ALL EXPOSURES CREATING FAILURE/DISLODGEMENT HAZARDS AFFECTING HEALTH&LIFE SAFETY:NOT MAINTAINED&MISSING DEBRIS NET+Open
Sep 24, 2026ECBUnknown: @8STORY NB SITE IN EXTERIOR PHASE W/UNSAFE SUPPORTED SCAFFOLD UP TO ROOF LEVEL TOWERING OVER ADJOIN PROPERTY 42-08 UNION STREET WITH NO PROTECTION OF ROOF IN PLACE TO CODE BC3309.10 NOR ENGINEERED ENCLOSURE SYSOpen
Jul 28, 2026ECBUnknown: BC 3314.1 AT TIME OF INSPECTION OBSERVED WORKER AT ROOF LEVEL WORKING ON A SUPPORTED SCAFFOLD NOT IN THE STATE OF READINESS, NO TOEBOARDS, NO PLANKS TIED DOWN OR GUARDRAIL SYSTEM AS REQUIRED IN 3314.5, 3314.5.5Closed
Jul 28, 2026ECBConstruction: OBSERVED VEHICLE EXITING THE SITE AT VEHICULAR ACCESS POINT NOT CLEARLY MARKED WITH HI VISIBILITY OR ADDITIONAL SUPPORT AT VERTICAL MEMBERS CREATING HAZARDOUS CONDITIONS TO THE STRUCTURAL STABILITY OF THE SHEDClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 2:49 PM ET. BBL 4051800038.

Look up another building