Queens · Block 4994 · Lot 24 · 11354

140-26 34 Avenue

4 floors · 3 apartments · 2,920 sq ft · built 2001 · class C0 · owner of record: Leavitt Union Management Corp.

42open violations
$0ECB/OATH penalties owed
1HPD class C (immediately hazardous)
50dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 50 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 50 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 66 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 294 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1146 days
Next cycle year 2029

Open violations

ECB / OATH (15)
IssuedViolationHearingBalance
Apr 5, 2006Construction Non-Hazardous
WORK W/O A PERMIT: EXPIRED PERMIT JOB #401202453 EXPIRED 3/25/06 2 MEN WORKING AT ROOF LEVEL. REMEDY: STOP ALL WORK-RENEW PERMIT.
#34517576X
Oct 10, 2006
WRITTEN OFF
$0
Mar 30, 2006Construction Non-Hazardous
FAILURE TO SAFEGUARD PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. ON INSPECTION BRICK WORK IN PROGRESS APPROX AT 50' HIGH ON EXTERIOR OF BUILDING WITHOUT ANY OVER HEAD PROTECT PROVIDED TO PROTECT TH
#34514209K
Oct 10, 2006
WRITTEN OFF
$0
Mar 30, 2006Construction Non-Hazardous
WORK WITHOUT A PERMIT. ON INSPECTION ADDITIONAL BRICK AND CEMET BLOCK WALL HAS BEEN ADDED ON PARAPET WALL AT ROOF LEVEL. NEW WALL IS ERECTEDAT APPROX. 50' ABOVE GRADE LEVEL AND A AREA OF APPROX 6' X 14'. D.O.B
#34514208Z
Oct 10, 2006
WRITTEN OFF
$0
Jul 18, 2002Construction Non-Hazardous
PLASTIC SKYLIGHTS TOP OF STAIR ENCLOSERE ARE NOT PERMITTED. SKY LIGHTS ARE NOT VENTED AND NO PROPER WIRE GRATTING PROVIDED ABOVE AND BELOW SKYLINGHT. REMEDY: PROVIDE PROPER SKYLING AND GRATING.
#34338815K
Feb 12, 2003
WRITTEN OFF
$0
Jul 18, 2002Construction Non-Hazardous
GUARD RAILS ARE NOT PROVIDED AT SECTION'S OF BRICK PARAPET THAT ARE LESS THAN 3F 6" REMEDY - PROVIDE GUARD RAILS AT PARAPET LEVEL AT ROOF
#34338585Y
Feb 12, 2003
WRITTEN OFF
$0
Jul 18, 2002Construction Non-Hazardous
LOT LINE WINDOWS ARE IMPROPERLY USED TO SUPPLY REQUIRED VENTILATION. REMEDY: PROVIDE PROPER VENTILATION.
#34338837L
Feb 12, 2003
WRITTEN OFF
$0
Jul 18, 2002Construction Non-Hazardous
CELLAR STAIR IS NOT ENCLOSED BECAUSE THERE IS NO FIRE PROOF SELF CLOSING DOOR AND NO RATED WALL AT TOP OF STAIRS. REMEDY: PROVIDE RATED ENCLOSING FIRE PROOF DOOR AT TOP STAIRS.
#34338848R
Feb 12, 2003
WRITTEN OFF
$0
Jul 18, 2002Construction Non-Hazardous
FAILURE TO PROVIDE ACCESS TO ROOF VIA INTERIOR STAIR. NO FOOF BULKHEAD PROVIDED FOR 4 FAMILY DWELLING. REMEDY: PROVIDE REQUIRED ACCESS TO ROOF.
#34338826X
Feb 12, 2003
WRITTEN OFF
$0
Jul 18, 2002Construction Non-Hazardous
EXTERIOR GAS SERVICE NOT PROPERLY PROTECTED BY BOLLARDS. FROM VEHICLURS TRAFFIC AT 1ST FLOOR PARKING AREA REMEDY - PROVIDE ADDITIONAL PROTECTION AROUND GAS SERVICES
#34338586X
Feb 12, 2003
WRITTEN OFF
$0
Jul 18, 2002Construction Non-Hazardous
BOILER FLUE NOT CARRIED 3 FEET ABOVE HIGHEST ROOF CONSTRUCTION ( PARAPET WALL ) REMEDY - RAISE FLUE PIPE 3 FEET ABOVE HIGHEST ROOF CONSTRUCTION
#34338599P
Feb 12, 2003
WRITTEN OFF
$0
Jul 18, 2002Construction Non-Hazardous
APARTMENT DOOR OPENS DIRECTLY TO STAIR ENCLOSURE WHICH IS NOT PERMITTED IN A BUILDING OVER THREE STORIES. REMEDY; COMPLY WITH CODE.
#34340895M
Feb 12, 2003
WRITTEN OFF
$0
Jun 10, 2002Construction Non-Hazardous
1-HOUR RATED BOILER ENCLOSURE (WALL) IS PENETRATED BY AN UNRATED 10" DIAMETER METAL BOILER FLUE COMPROMISING INTEGRITY OF ONE HOUR RATED WALL REMEDY - PROVIDE 1-HOUR FIRE PROTECTION AROUND BOILER FLUE
#34338684J
Feb 12, 2003
WRITTEN OFF
$0
Jun 7, 2002Construction Non-Hazardous
FAILURE TO PROVIDE REQUIRED NUMBER OF PARKING SPACES IN AN R6 DISTRICT ENCLOSED ACCESSARY OFF STREET PARKING SPACE DOES NOT MEET MININUM DIMENSIANS OF 18.5 X 8. UNENCLOSED OFF STREET PARKING SPACES AT REAR ARE
#34333534L
Feb 12, 2003
WRITTEN OFF
$0
Jun 7, 2002Construction Non-Hazardous
WORK CONTRARY TO PLANS IN THAT GARAGE DIMERSIONS SMALLER THAN SPECIFICED 2 ROOF DECKING CONSTRUCTED OF PLYWOOD INSTEAD OF METAL AND CONCROTE3 REAR LOT RETAINING WALL NOT SHOWN ON PLANS 4 CURB CUT IS 55 FEET IN
#34338395N
Feb 12, 2003
WRITTEN OFF
$0
Jun 7, 2002Construction Non-Hazardous
LOT LINE WINDOWS INSTALLED WITHOUT A PERMIT NOT SHOWN OR PLANS. REMEDY: OBTAIN A PERMIT OR REMOVE. WINDOWS.
#34340884R
Feb 12, 2003
WRITTEN OFF
$0
DOB (9)
IssuedViolationStatus
May 31, 2007SEU
AS BUILT CONDITIONS NOT CONFORMING TO APPROVED PLANS AS FOLLOWS: WIND OWS, NO HC ACCESS, INDIVIDUAL GRATES, EXTERIOR GAS AND ELECTRIC METERS W/ BOLLARDS 4" CMU FACADE, NO FIRE RATED STEEL BRICK SHELVES ANC BALC ONIES, PARAPET HEIGHTS PAINTED PARKING IN DRIVEWAY, NO 30FT FDNY ACCES S, 60FT CURB CUT,
#229071
DOB VIOLATION - ACTIVE
May 31, 2007SEU
AS BUILT CONDITIONS NOT CONFORMING TO APPROVED PLANS AS FOLLOWS: WINDO WS, NO HC ACCESS, INDIVIDUAL GRATES, EXTERIOR GAS AND ELECTRIC METERS W/ BOLLARDS, 4"CMU FACADE, NO FIRE RATED STEEL BRICK SHELVES AND BALCO NIES, PARAPET HEIGHTS, PAINTED PARKING IN DRIVEWAY, NO 30FT FDNY ACCES S, 60' CURB CUT,
#229063
DOB VIOLATION - ACTIVE
May 31, 2007SEU
AS BUILT CONDITIONS NOT CONFORMING TO APPROVED PLANS AS FOLLOWS: WINDO WS, NO HC ACCESS, INDIVIDUAL GRATES, EXTERIOR GAS AND ELECTRIC METERS W/ BOLLARDS 4" CMU FACADE, NO FIRE RATED STEEL BRICK SHELVES AND BALCO NIES, PARAPET HEIGHTS, PAINTED PARKING IN DRIVEWAY, NO 30 FT FDNY ACCE SS, 60FT CURB CUT
#229072
DOB VIOLATION - ACTIVE
May 21, 2007SEU
AS BUILT CONDITIONS NOT CONFORMING TO APPROVED PLANS AS FOLLOWS: WINDO WS, NO HC ACCESS, INDIVIDUAL GRATES, EXTERIOR GAS AND ELECTRIC METERS W/ BOLLARDS, 4" CMU FACADE, NO FIRE RATED STEEL BRICK SHELVES AND BALC ONIES, PARAPET HEIGHTS, PAINTED PARKING IN DRIVEWAY, NO 30FT FDNY ACCE SS, 60' CURB CUT,
#229067
DOB VIOLATION - ACTIVE
Jul 18, 2002CONSTRUCTION

#07214OC
DOB VIOLATION - ACTIVE
Jul 18, 2002CONSTRUCTION

#0706OC
DOB VIOLATION - ACTIVE
Jul 18, 2002CONSTRUCTION

#07210OC
DOB VIOLATION - ACTIVE
Jul 14, 2002CONSTRUCTION

#0759OC
DOB VIOLATION - ACTIVE
Jul 10, 2002CONSTRUCTION

#0701V
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 7)
Active
HPD (17) · C 1 · B 4 · A 12
IssuedClassViolationCorrect by
May 7, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 10, 2026
Jun 12, 2025A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Sep 15, 2025
Apr 16, 2024A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jul 20, 2024
Mar 30, 2023A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jul 3, 2023
Mar 8, 2022A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jun 11, 2022
Apr 16, 2021A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jul 20, 2021
Dec 18, 2017C§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER LOCK ON EXTERIOR METAL DOOR TO BUILDING. AT PUBLIC HALL, 1st STORYDec 26, 2017
Dec 18, 2017A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYMar 23, 2018
Dec 18, 2017A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING. AT PUBLIC HALL, 1st STORYMar 23, 2018
Dec 18, 2017A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYMar 23, 2018
Dec 18, 2017A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORYMar 23, 2018
Dec 18, 2017A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYMar 23, 2018
Dec 18, 2017A§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX ,, AT PUBLIC HALL, 1st STORYMar 23, 2018
Dec 18, 2017BApt 4F · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORYJan 22, 2018
Dec 18, 2017BApt 4F · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR WHICH IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORYJan 22, 2018
Dec 18, 2017BApt 4F · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORYJan 22, 2018
Dec 18, 2017B§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF STORAGE OF DISUSED HOUSE HOLD ITEMS. ETC. AT PUBLIC HALL STAIRS TO BULH-HEAD AT PUBLIC HALL, 4th STORYJan 22, 2018

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 11, 2026, 3:17 PM ET. BBL 4049940024.