7 floors · 71,732 sq ft · built 1915 · class O3 · owner of record: Nyc Department Of Citywide Administrative Services
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 56 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $114,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 108 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 71,732 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 177 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 177 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 787 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 154). Agency page | Dec 31, 2034 in 2978 days | Next due 2034 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 5, 2023 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS & FACADE.OBSERVED CRACKED/SPALLED BRICKS/STONE DAMAGED WINDOW SILLS/LINTELS,DAMANGED MORTAR JOINTS & LARGE STEP CRACKS IN MULTIPLE LOCATIONS ON EXP #1 SOUTH ELEVATION #35669424X | Jul 13, 2023 POP/IN-VIO | $0 |
| Dec 2, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#919121.REMEDY:SUBMIT ACCEPTABLE REQUIRE #37023488P | Feb 9, 2023 POP/IN-VIO | $0 |
| Oct 21, 2022 | Elevators CLASS - 2 97X17: 97-X-17 CLASS 2 RTS REPAIR ELEVATOR & RESTORE TO SERVICE IMMEDIATELY CALL NYC DEPT OF BUILDINGS ELEVATOR DIVISION FOR REINSPECTION AND EMAIL ELEVATORIR@BUILDINGS.NYC.GOV FOR REINSPECTION #38274497J | Jan 26, 2023 POP/IN-VIO | $0 |
| Nov 15, 2019 | Construction CLASS - 2 SEC. 27-929.1 A.C.27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS& FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BLDG #37016912J | Jan 23, 2020 POP/IN-VIO | $0 |
| Sep 25, 2008 | Unknown CLASS - 1 FAILURE TO FILE AFFIDAVITS AND OR COMPLY W/ OTHER REQUIREMENTS SET FORTH FOR PHOTOLUMINESCENT EXIT PATH MARKING. REMEDY: COMPLY W/ REQUIREMENTS OF REFERENCE STANDARDS RS 6-1 #36000175X | Dec 18, 2008 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 7, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. EXP 1 SOUTH SPALLED DAMAGED, DECORATIVE MASONRY LINTEL ON 2FL.VERTICAL CRACKS IN MASONRY ON 2FL. SPANDRELS ALSO ON EXP2 2FL. SPANDREL VERTICAL CRACKS CAN BE SEEN. ERODED BRICK. REMEDY: REPAIR AND OR REPLACE DAMAGE MASONRY #SR0103RF | DOB VIOLATION - ACTIVE |
| Sep 3, 2019 | SPRINKLER FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019 #NRF00691 | DOB VIOLATION - ACTIVE |
| Nov 1, 2006 | PHOTOLUMINESCENT #NRF00641 | DOB VIOLATION - ACTIVE |
| Jun 30, 2000 | ELEVATOR #9011/123805 | DOB VIOLATION - ACTIVE |
| Jun 24, 1992 | ELEVATOR #1106A1 | VIOLATION UNSERVED ECB-ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
| Sep 3, 2019 | Sprinklers FTF-SP-FINAL | Active |
| Nov 1, 2006 | Photoluminescent FTF-EL-PHOTOL | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)