6 floors · 12 apartments · 9,422 sq ft · built 1935 · class D1 · owner of record: 14 Duffield Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 69 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 85 days | Annual |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1165 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 16, 2026 | Construction CLASS - 2 OBSERVED SIDEWALK SHED INSTALLED AT EXP# 1 MISSING SWS PARAPET INFORMATION PANEL CONTRARY TO BC 3301.9.2 MISSING INFORMATION PANEL CAN DELAY RESPONSE IN CASE OF AN EMERGENCY NOT HAVING THE ADDRESS POSTED AS PER #39550409P | Nov 2, 2026 | $1,250 |
| Feb 16, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION OBSERVED SIDEWALK SHED INSTALLED AT EXPOSURE#1 UPON REVIEWING DOB NOW AND BIS RECORDS INDICATED NO PERMIT ON FILED / OR OBTAINED #39550408N | Nov 2, 2026 PENDING | $1,250 |
| Feb 13, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. AT TIME OF INSPECTION, OBSERVED THE EXTERIOR FACADE EXP 2 AND 4 OF THE BUILDING IN DISREPAIR. NOTED VERTICAL CRACKS RUNNING UPWARDS FROM 3RD FLOOR TO THE R #39177288P | May 19, 2027 | $5,000 |
| Feb 13, 2026 | Unknown CLASS - 1 ELECTRICAL WORK WITHOUT PERMIT. AT TIME OF INSPECTION, OBSERVED ILLEGAL ELECTRICAL WORK COMPLETED ON THE ROOF OF THE BUILDING. HVAC CONDENSERS/EQUIPMENT REMOVED FROM EXISTING ROOF LEVEL AND INSTALLED ON TOP OF #39177290Y | May 19, 2027 PENDING | $2,500 |
| Feb 13, 2026 | Construction CLASS - 1 WORK WITHOUT PERMIT. ATOI, OBSERVED THE ROOF OF A 6 STORY BUILDING HAS BEEN ILLEGALLY ALTERED/CHANGED. NOTED ROOF VERTICALLY/HORIZONTALLY ENLARGED, AND FULLY ENCLOSED FROM FRONT TO REAR, CREATING 7TH FLOOR. CON #39177289R | May 19, 2027 PENDING | $2,500 |
| Feb 13, 2026 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. AT TIME OF INSPECTION, OBSERVED AT CELLAR LEVEL. APT. 1F (DUPLEX) CELLAR EGRESS DOOR LEADING TO HALLWAY BLOCKED/OBSTRUCTED BY BED. CELLAR STAIRS LEADING TO 1ST F #39177299K | May 19, 2027 | $2,500 |
| Feb 13, 2026 | Construction CLASS - 1 OCCUPANCY CONTRARY TO CERTIFICATE OF OCCUPANCY OR BUILDING RECORDS. AT TIME OF INSPECTION, OBSERVED INSIDE 1ST FLOOR DUPLEX APT. UNIT 1F. 1 MALE USING CELLAR AS SLEEPING QUARTERS. NOTED FULL SIZE BED WITH PILLO #39177297R | May 19, 2027 | $2,500 |
| Oct 2, 2019 | Construction CLASS - 1 FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED AT TIME OF INSPECTION I OBSERVED A BUILDING WITH INCOMPLETE FACADE TO ABOVE THE 2ND FLOOR(APPROX 20' ABOVE SIDEWALK GRADE)I ALSO NOTED THAT NO SIDEWALK SHED HAD B #35449411M | Jan 11, 2021 IN VIOLATION | $10,000 |
| Aug 8, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. ATTHE TIME OF MY INSPECTION ON AN ACTIVE JOBSITE OF A 6 STY BLDG. I OBSERVED @ EXP#1 ON SITE,THE 1ST & 2ND FL. ALSO ON THE TOP OF THE SWS AT #35448734M | Dec 9, 2019 IN VIOLATION | $2,500 |
| Apr 23, 2019 | Unknown CLASS - 2 FAILURE TO OBTAIN A TEMPORARY CONSTRUCTION PERMIT PRIOR TO INSTALLATION/USE OF TEMPORARY CONSTRUCTION EQUIPEMNT.NOTE:AT TIME OF INSPECTION I OBSERVED CONSTRUCTION EQUIPMENT.NOTE:AT TIME OF INSPECTION I OBSERVED #35418350X | Feb 3, 2020 IN VIOLATION | $625 |
| Apr 23, 2019 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.NOTE:AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE.FAILURE TO MAINTAIN 8 FT FOR PEDESTRIAN OBSERVED BRICIES UNDER 8 FT HIGH #3307.6.4.7 (2) I OB #35418273L | Feb 3, 2020 IN VIOLATION | $2,400 |
| Jan 24, 2019 | Construction CLASS - 1 3307.6.5.10.1 FAILURE TO PERFORM DAILY INSPECTION (SIDEWALK SHED) AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED ON EXPOSURE #1 OF BLDG ANDNO DAILY INSPECTION LOG WAS NOT PROVIDED UPON DEMAND. NO DAILY INSPEC #35384750M | Feb 26, 2020 IN VIOLATION | $2,500 |
| Jan 24, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN SIDEWALK SHED. AT TIME OF INSPECION I OBSERVED 2 EXPOSRUE #1 SWS FOOTING BLOCKS VISIBLY UNSOUND AND APPREARED TO BE UNSAFE DUE TO THE FACT THAT ITS BROKEN /CRACKED APART. ALL WORK #35380899M | Feb 26, 2020 IN VIOLATION | $2,400 |
| Jan 16, 2019 | Construction CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO GUARD RAILS. AT TIME OF INSPECTION ON A 6 STORY BUILDING OBSERVED INADEQUATE GUARDRAILS AT EXP 3 WINDOWS EXP 1 WINDOWS AND AT #35377870L | Jul 22, 2019 IN VIOLATION | $2,500 |
| Dec 18, 2018 | Unknown CLASS - 2 RESPONDENT FAILED TO MAKE PROPER NOTIFICATION FOR MOBILE CRANE AFTER MAY 1,2018 TO THE DEPARTMENT.AT THE TIME OF INSPECTION CN93818 WAS NOTON SITE. SCREEN SHOT OF NYCDOB CRANE NOTIFICATION WEB PAGE CLEARLY #35360645Y | Aug 19, 2019 IN VIOLATION | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Feb 13, 2026 | CONSTRUCTION WORK WITHOUT PERMIT. ATOI, OBSERVED ROOF OF A 6 STORY BUILDING HAS BEEN ILLEGALLY ALTERED. NOTED ROOF VERTICALLY/HORIZONTALLY ENLARGED, & FULLY ENCLOSED, CREATING 7TH FLOOR. NOTED VERTICAL CRACKS RUNNING FROM 3RD FLR. TO THE ROOF AT EXP2 & EXP4. CREATING AN IMMEDIATE UNSAFE HAZARD FOR OCCUPANTS, NEA #26-00567 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 23, 2026, 4:15 PM ET. BBL 3001080019.