Manhattan · Block 197 · Lot 7502 · 10013

139 Centre Street

9 floors · 127,401 sq ft · built 1911 · class RI · owner of record: Unavailable Owner

9open violations
$6,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
68dto Annual boiler inspection (2 boilers)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-17 (Accepted). Agency page

Dec 31, 2026
in 68 days
2 of 2 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 127,401 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 189 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 189 days
Annual filing
Energy audit and retro-commissioning (2027) Likely applies
Local Law 87 · Calendar year 2027
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 197). Agency page

Dec 31, 2027
in 433 days
Next due 2027
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 799 days
Next cycle year 2028
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $315,000 in late-filing or failure-to-file penalties. Agency page

On fileCycle 10 filing on record: SWARMP (2026-02-02)

Open violations

ECB / OATH (6) · $6,250 owed
IssuedViolationHearingBalance
Apr 11, 2024Local Law CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #900439.REMEDY:SUBMIT ACCEPTABLE REQUIRE TEC
#37027605N
Mar 20, 2025
ADMIT/IN-VIO
$0
Jun 3, 2021Construction CLASS - 2
FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER TO FILE CERTIFICATE OF CORRECTION W/ THE DOB FOR VIOLATING CONDITIONS CITED ON NOV#35472950R ISSUED ON:3/19/2020 PURSUANT TO 28-201.1:28-204.4:1RCNY 102-01. REMEDY:
#35546715X
Dec 16, 2021
DEFAULT
$3,125
Mar 30, 2021Construction CLASS - 2
27-929.1 AC27-929.1,FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OFAUTOMATIC SPRINKLERS&FILE FINAL SPRINKLER REPORT PREPARED BY REGISTERED DESIGN PROFESSIONAL IN OFFICE BLDG 100' OR MORE IN HT IN EXISTENCE O
#37020889M
Sep 9, 2021
IN VIOLATION
$0
Jul 13, 2020Construction CLASS - 2
A.C. 27-919.1.FAILURE TO COMPLETE THE INSTALLATION OF A FULL YSTSEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY JULY 1, 2019 IN AN OFFICE BUILDING 1
#37019717H
Oct 15, 2020
ADMIT/IN-VIO
$0
Mar 19, 2020Construction CLASS - 2
AC282011/EONO100-UNLAWFUL ACTS VIOLATION OF EMERGENCY EXECUTIVE ORDER.NO100 DINE IN/DRINK IN AT LOCATION.AT TIME OF INSPECTION 2 PERSON WEREOBSERVED DINING IN AND DRINKING OF DUNKIN DONUTS.REMEDY:COMPLY WITH EM
#35472950R
Sep 24, 2020
DEFAULT
$3,125
Nov 15, 2019Construction CLASS - 2
27-929.1 A.C. 27-929-1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BUILDIN
#37016053K
Feb 13, 2020
STIPULATION/IN-VIO
$0
DOB (3)
IssuedViolationStatus
Feb 22, 2023NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
#02004
DOB VIOLATION - ACTIVE
Aug 6, 2018CONSTRUCTION

#CN0101GK
DOB VIOLATION - ACTIVE
Aug 6, 2018CONSTRUCTION

#CN01GK
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Aug 24, 2026GHG Emissions - LL97 FTX-EN-LL97320
Active
Feb 22, 2023Facades FISPNRF
CYCLE 9B NO REPORT FILED
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Aug 24, 2026DOB SafetyGHG Emissions - LL97: Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 1:16 PM ET. BBL 1001977502.

Look up another building