6 floors · 37,995 sq ft · built 2017 · class H3 · owner of record: Pride Management Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 37,995 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 181 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 181 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 425 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 23, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED ILLEGAL HARDWARE ON DOORS THROUGHOUT THE BUILDING. IN AN EMERGENCY IF A PERSON TRAP, THIS HARDWARE WILL DELAY RESPONSE TIME FOR 1ST RESPONDERS., R #39205216L | Dec 1, 2026 | $2,500 |
| Sep 23, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED STAIRCASE B EMERGENCY EXIT DOOR OBSTRUCTED. LOCATED AT CELLAR LEVEL. POTENTIAL FIRE HAZARD., REPAIR AND/REPLACE #39205217N | Dec 1, 2026 | $2,500 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Report | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 23, 2026 | ECB | Unknown: ATOI OBSERVED IN SUB CELLAR CAFERTERIA ELECTRICAL BOX MISSING COVER, WIRES ARE EXPOSED CREATING A SAFETY HAZARD. PER EC 110.2(A) UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, | Closed |
| Sep 23, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED ILLEGAL HARDWARE ON DOORS THROUGHOUT THE BUILDING. IN AN EMERGENCY IF A PERSON TRAP, THIS HARDWARE WILL DELAY RESPONSE TIME FOR 1ST RESPONDERS., R | Closed |
| Sep 23, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED STAIRCASE B EMERGENCY EXIT DOOR OBSTRUCTED. LOCATED AT CELLAR LEVEL. POTENTIAL FIRE HAZARD., REPAIR AND/REPLACE | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 6:35 PM ET. BBL 4099820023.