5 floors · 76 apartments · 72,500 sq ft · built 1924 · class C7 · owner of record: 1381 Castle Realty Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 46 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 46 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 62 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 72,500 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 167 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 167 days | Annual filing |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3935). Agency page | Dec 31, 2035 in 3333 days | Next due 2035 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-23 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 9, 2025 | Unknown CLASS - 1 I OBSERVED UNSAFE UNSUITABLE ELECTRICAL CONDITIONS IN ELECTRICAL ROOM, MAIN OVERCURRENT PROTECTION (600 AMPS) IN BOTH SERVICE DISCONNECT SWITCHES ARE OVERSIZE FOR SERVICE ENTRANCE CONDUCTORS (600 KCMIL)., COMPL #39159786Z | Nov 21, 2025 DEFAULT | $4,000 |
| Nov 23, 2013 | Boilers CLASS - 1 B154,1,51. #32073924X | Apr 11, 2014 IN VIOLATION | $0 |
| Nov 16, 2013 | Boilers CLASS - 1 B154,303,15,16,51,40. 50A-OPENING IN CHIMNEY FUMES. #32073918J | Jan 24, 2014 IN VIOLATION | $0 |
| Aug 31, 2010 | Signs CLASS - 1 OAC SIGN ON DISPLAY STRUCTURE W/O APERMIT."FIDELIS CARE"REM:REMOVE ILLEGAL WORK OR OBTAIN PERMIT #34878822X | May 6, 2011 IN VIOLATION | $0 |
| Aug 31, 2010 | Signs CLASS - 2 OAC SIGN ON DISPLAY STRUCTURE W/O A PERMIT."FIDELIS CARE"REM:REMOVE ILLEGAL WORK OR OBTAIN PERMIT #34878858H | Jun 10, 2011 IN VIOLATION | $0 |
| Aug 31, 2010 | Signs CLASS - 1 OAC SIGN ON DISPLAY STRUCTURE W/O APERMIT."CAPITAL ONE"REM:REMOVE ILLEGAL WORK OR OBTAIN PERMIT #34878823H | May 6, 2011 IN VIOLATION | $0 |
| Aug 31, 2010 | Signs CLASS - 1 OAC SIGN ON DISPLAY STRUCTURE W/O A PERMIT."CAPITAL ONE"REM:REMOVE ILLEGAL WORK OR OBTAIN PERMIT #34878859J | May 6, 2011 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2024 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2400914 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #10036 | DOB VIOLATION - ACTIVE |
| Apr 29, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2002626 | DOB VIOLATION - ACTIVE |
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00137 | DOB VIOLATION - ACTIVE |
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00138 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2024 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 29, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 7, 2026 | B | Apt B5 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT ALL WALLS AND CEILING IN THE BATHROOM LOCATED AT APT B5, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''1383'' ORIGINAL VIOLATION 18683737 ISSUED 04-MAR-26 HAS BEEN UPGRADED TO CLASS B | Aug 11, 2026 |
| Mar 5, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Mar 11, 2026 |
| Mar 4, 2026 | C | Apt B2 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT B2, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''1381'', AT SOUTH | Mar 18, 2026 |
| Mar 2, 2026 | C | Apt E3 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT E3, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 2, 2026 |
| Mar 2, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM, 1st STORY | Mar 8, 2026 |
| Feb 9, 2026 | A | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE HOUSEHOLD ITEMS AT FRONT COURT | May 15, 2026 |
| Feb 9, 2026 | B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CONSTRUCTION DEBRIS, GARBAGE AT FRONT COURT | Mar 16, 2026 |
| Jan 23, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLIES AT DOOR FROM VESTIBUL TO 2ND STY AT PUBLIC HALL, 2nd STORY | Feb 27, 2026 |
| Jan 13, 2026 | C | Apt B2 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL, WEST WALL, 1st WINDOW FRAME FROM NORTH AT EAST | Feb 20, 2026 |
| Jan 13, 2026 | C | Apt B2 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM SOUTH AT WEST WALL DOOR, 1st CLOSET FROM SOUTH AT WEST WALL DOOR FRAME | Feb 20, 2026 |
| Jan 13, 2026 | B | Apt B2 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN GLAZE AT BATHTUB IN THE BATHROOM LOCATED AT APT B2, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''1381'', AT SOUTH | Feb 17, 2026 |
| Jan 13, 2026 | C | Apt B2 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) EAS | Feb 20, 2026 |
| Jan 13, 2026 | B | Apt B2 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT APT B2, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SE | Feb 17, 2026 |
| Jan 13, 2026 | C | Apt B2 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM WEST AT NORTH WALL, 1st DOOR FRAME FROM EAST AT SOUTH WALL, SOUTH | Feb 20, 2026 |
| Jan 13, 2026 | B | Apt B2 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT B2, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST , SEC | Feb 17, 2026 |
| Dec 31, 2025 | C | Apt A6 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT A6, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 31, 2025 |
| Dec 19, 2025 | C | Apt 7E · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 7E, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 19, 2025 |
| Dec 19, 2025 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Dec 25, 2025 |
| Dec 19, 2025 | C | Apt 7E · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 7E, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 19, 2025 |
| Nov 24, 2025 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR , 2nd STORY | Nov 30, 2025 |
| Aug 13, 2025 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS ON BALCONY AT 1ST FIRE ESCAPE FROM SOUTH AT EAST BUILDING FRONT AT FIRE ESCAPE, 5th STORY | Sep 17, 2025 |
| Aug 13, 2025 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CRACKED GLASS AT INTERCOM SYSTEM PREVENTING INTERCOM FROM WORKING PROPERLY AT COURT , 2nd STORY, SECTION ''1387'' | Sep 17, 2025 |
| Aug 13, 2025 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS ON BALCONY AT 1ST FIRE ESCAPE FROM SOUTH AT EAST BUILDING FRONT AT FIRE ESCAPE, 6th STORY | Sep 17, 2025 |
| Aug 13, 2025 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS ON BALCONY AT 1ST FIRE ESCAPE FROM SOUTH AT EAST BUILDING FRONT AT FIRE ESCAPE, 4th STORY | Sep 17, 2025 |
| Aug 13, 2025 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF A AIR CONDITIONER PROTRUDING MORE THAN 6 INCHES ON BALCONY AND FLOWER POTS AT 1ST FIRE ESCAPE FROM EAST AT NORTH EXTERIOR WALL AT FIRE ESCAPE, 5th STORY | Sep 17, 2025 |
| Jul 22, 2025 | B | Apt E1 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD DOOR AT ENTRANCE IN THE BATHROOM LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 26, 2025 |
| Jul 22, 2025 | C | Apt E1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 17, 2025 |
| Jul 22, 2025 | B | Apt E1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE BATHROOM LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 26, 2025 |
| Jul 22, 2025 | B | Apt E1 · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT WASHBASIN IN THE BATHROOM LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 26, 2025 |
| Jul 22, 2025 | C | Apt E1 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 5, 2025 |
| Jul 22, 2025 | B | Apt E1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE FOYER LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 26, 2025 |
| Jul 22, 2025 | C | Apt E1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 17, 2025 |
| Jul 22, 2025 | B | Apt E1 · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT SINK IN THE KITCHEN LOCATED AT APT E1, 5th STORY | Aug 26, 2025 |
| Jul 22, 2025 | B | Apt E1 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT E1, 5th STORY | Aug 26, 2025 |
| Jun 3, 2025 | A | Apt B15 · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION 220 VOLT OUTLET AT SOUTH WALL IN THE KITCHEN LOCATED AT APT B15, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''1387'' | Sep 6, 2025 |
| Jun 3, 2025 | C | Apt B15 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE THE HINGES IN THE ENTRANCE LOCATED AT APT B15, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST , SECTION ''1387'' | Jun 17, 2025 |
| Apr 14, 2025 | B | Apt D4 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTISE LOCK (LATCH BROKEN/MISSING) AT APARTMENT DOOR IN THE ENTRANCE LOCATED AT APT D4, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | May 19, 2025 |
| Apr 10, 2025 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DISCARDED RANGE WITH DOOR ATTACHED AT SOUTH WALL AT 4TH STORY AT PUBLIC HALL, SECTION ''SOUTH'' | May 15, 2025 |
| Apr 10, 2025 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF WOOD DRESSER AT SOUTH WALL AT 5TH STORY AT PUBLIC HALL, SECTION ''north'' | May 15, 2025 |
| Apr 10, 2025 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS [COOLER, BICYCLE, STROLLER, AND CAR SEAT AT EAST WALL AT 2ND STORY AT PUBLIC HALL, SECTION ''north'' | May 15, 2025 |
| Feb 26, 2025 | B | Apt D1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 5 SQ.FT AT WINDOW FRAME IN THE BATHROOM LOCATED AT APT D1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 2, 2025 |
| Oct 4, 2024 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT 1ST FROM EAST AT NORTH 5TH BALCONY AT FIRE ESCAPE | Nov 8, 2024 |
| Oct 4, 2024 | A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION STORAGE UNIT UNDER STAIRS CONSISTING OF METAL GATE 2ND STORY PUBLIC HALL SECTION 1385 , 2nd STORY | Jan 7, 2025 |
| Oct 4, 2024 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT 1ST FIRE ESCAPE FROM EAST AT NORTH 3RD BALCONY AT FIRE ESCAPE | Nov 8, 2024 |
| Oct 1, 2024 | B | Apt C14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 1SQFT AT CEILING IN THE BATHROOM LOCATED AT APT C14, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17018245 ISSUED 30-MAY-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3 | Nov 5, 2024 |
| Aug 23, 2024 | B | Apt D14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WINDOW CASING AT EAST 1 WINDOW ( APPROX 1 SQFT) IN THE 4th ROOM FROM NORTH LOCATED AT APT D14, 4th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16929841 ISSUED 22-APR-24 HAS BEEN UPGRADED TO CLASS B | Sep 27, 2024 |
| Aug 23, 2024 | B | Apt C14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL ( APPROX 3 SQFT), WINDOW FRAME AT EAST 1 WINDOW ( APPROX 1 SQFT) AND WINDOW FRAME AT EAST 2 WINDOW ( APPROX 3 SQFT) IN THE 2nd ROOM FROM NORTH LOCATED AT APT C14, 3rd STORY, 1st APARTMENT FROM NORTH AT | Sep 27, 2024 |
| Aug 23, 2024 | B | Apt C14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL ( APPROX 1 SQFT). WINDOW FRAME AT EAST 1 WINDOW ( APPROX 1 SQFT) AND CEILING ( APPROX 1 SQFT) IN THE 4th ROOM FROM NORTH LOCATED AT APT C14, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATIO | Sep 27, 2024 |
| Aug 23, 2024 | B | Apt C14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING ( APPROX 1 SQFT) IN THE BATHROOM LOCATED AT APT C14, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16929942 ISSUED 22-APR-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017. | Sep 27, 2024 |
| Aug 23, 2024 | B | Apt D14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL ( APPROX 1 SQFT) IN THE 2nd ROOM FROM NORTH LOCATED AT APT D14, 4th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16929844 ISSUED 22-APR-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE C | Sep 27, 2024 |
| Jul 22, 2024 | B | Apt D14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 5 SQ FT NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT D14, 4th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16759978 ISSUED 21-MAR-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIV | Aug 26, 2024 |
| Jul 22, 2024 | B | Apt D14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 5 SQ FT AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT D14, 4th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16759981 ISSUED 21-MAR-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRAT | Aug 26, 2024 |
| Jul 9, 2024 | B | Apt C14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 8 SQ. FT. AT EAST WALL AND 1 SQ. FT. AT CEILING. IN THE 4th ROOM FROM NORTH LOCATED AT APT C14, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''1387'' ORIGINAL VIOLATION 16732455 ISSUED 06-MAR-24 HAS | Aug 13, 2024 |
| May 30, 2024 | C | Apt D14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 10 SQ FT AT EAST WALL IN THE BATHROOM LOCATED AT APT D14, 4th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16759967 ISSUED 21-MAR-24 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE § | Jun 25, 2024 |
| May 21, 2024 | B | Apt C12 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 5 SQ FT AROUND WINDOW CASING AT 1ST WINDOW FROM NORTH AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT C12, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 16612026 ISSUED 21-JAN-24 HAS BE | Jun 25, 2024 |
| Apr 30, 2024 | C | Apt D14 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT D14, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | May 26, 2024 |
| Apr 29, 2024 | B | Apt C14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL APPROX 15 SQ FT IN THE 4th ROOM FROM NORTH LOCATED AT APT C14, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''1387'' | Jun 3, 2024 |
| Apr 29, 2024 | B | Apt C14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL APPROX 10 SQ FT IN THE 2nd ROOM FROM NORTH LOCATED AT APT C14, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''1387'' | Jun 3, 2024 |
| Apr 15, 2024 | B | Apt E9 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 5 SQ FT AT NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT E9, 5th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 16518835 ISSUED 13-DEC-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRA | May 20, 2024 |
| Apr 12, 2024 | B | Apt C14 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 10 SQ. FT. AT CEILING AND EAST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT C14, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''1387'', AT NORTH | May 17, 2024 |
Showing 60 of 132. Full list on the agency site.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)