Queens · Block 4956 · Lot 55 · 11354

138-11 35 Avenue

2 floors · 26,400 sq ft · built 1900 · class W1 · owner of record: Nyc Department Of Education

11open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
171dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 50 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 26,400 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 171 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 171 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1146 days
Next cycle year 2029
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-11-02 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (6)
IssuedViolationHearingBalance
Mar 12, 2026Construction CLASS - 2
REISSUE #35725143N. DATE OF ISSUE: 09/23/2025. EXIT DOOR NOT SELF-CLOSING PROPERLY AT THE TIME OF INSPECTION AT BASEMENT LEVEL STAIRWAY "A" AND 1ST FLOOR LEVEL STAIRWAY "A" AND 2ND FLOOR STAIRWAY "D" ONE EXIT D
#35728696R
Apr 10, 2026
POP/IN-VIO
$0
Mar 12, 2026Construction CLASS - 2
REISSUE #35725142L. DATE OF ISSUE: 09/23/2025. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED ANDNOTED EXIT #3(REAR), IN FRONT NEAR EXIT-1, OUTSIDE CONCRETE WORK CRACK
#35728697Z
Apr 10, 2026
POP/IN-VIO
$0
Sep 23, 2025Construction CLASS - 2
REISSUE: 35678928Y DATE OF ISSUE: 04-01-2024. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED EXIT #3(REAR), IN FRONT NEAR EXIT-1 OUTSIDE CONCRETE WORK CRACKE
#35725142L
Oct 21, 2025
POP/IN-VIO
$0
Sep 23, 2025Construction CLASS - 2
REISSUE #35678927M DATE OF ISSUE: 04-01-2024. EXIT DOOR NOT SELF-CLOSING PROPERLY AT THE TIME OF INSPECTION. OBSERVED AND NOTED AT BASEMENT LEVEL STAIRWAY "A" ONE EXIT DOOR, AT 1ST FLOOR STAIRWAY "A" EXIT-1 AND
#35725143N
Oct 21, 2025
POP/IN-VIO
$0
Apr 1, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED AT EXP#3(REAR)FARE POST FOOLINGS,BROKEN,CRACKED & MISSING PIECES OF CONCRETE,AT SEVERAL LOCATIONS.REM:REPAIR AND/OR REPLACE.
#35678928Y
May 13, 2024
POP/IN-VIO
$0
Apr 1, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:FIREPROOF SELF CLOSING INTERIOR DOORS AT 2ND FL STAIRWELL A ARE WARPED AT 1ST FLSTAIRWELL DOOR IS MISSING DOOR CLOSER.BOTH DOOR NOT CLOSING PROPERLY.R
#35678927M
May 13, 2024
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (5)
IssuedViolationStatus
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 11, 2026, 9:43 AM ET. BBL 4049560055.