Queens · Block 12572 · Lot 7501 · 11434

137-12 167 Street

2 floors · 20 apartments · 16,180 sq ft · built 1988 · class R3 · owner of record: Baisley Park Plaza Condo

20open violations
$0ECB/OATH penalties owed
1HPD class C (immediately hazardous)
56dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 56 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 56 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 72 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 300 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 421 days
Next cycle year 2027

Open violations

ECB / OATH (0)

None open.

DOB (4)
IssuedViolationStatus
Sep 29, 2022CONSTRUCTION
FAIL TO MAINTAIN-ON/AROUND 7/13/22,A VEHICLE IMPACTED EXP3 REAR WALL @1ST FLOOR.REAR WALL STRUCTURALLY COMPROMISED OWNR RTAIN NYSPE-EVAL ENTIRE BLDG &PREPARE RPR DWGS.BLDG TO BE RPRD UNDR PRMT STRTNG 11/21/22 &CMPLTD/SIGN OFF 12/30/22
#FEU41203PN
DOB VIOLATION - ACTIVE
Jul 14, 2022IMMEDIATE EMERGENCY
SEAL ALL ACCESSIBLE OPENINGS TO SECURE AGAINST UNAUTHORIZED ACCESS AND TO SAFEGUARD THE PUBLIC
#17045
DOB VIOLATION - ACTIVE
Jul 13, 2022CONSTRUCTION
PREMISE NON-COMPLIANT DUE TO A VEHICLE STRIKING THE REAR EXPOSURE WALL DISPLACING 8 VERTICAL MEMBERS RENDERING THE PREMISE NON-COMPLIANT AT TIME OF INSPECTION
#22-02216
DOB VIOLATION - ACTIVE
Jul 13, 2022CONSTRUCTION
PREMISES NON-COMPLIANT DUE TO A VEHICLE STRIKING THE EXPOSURE 3 REAR WALL DISPLACING 8 VERTICAL MEMBERS AND SHEATHING RENDERING THE PREMISE NON-COMPLIANT
#22-02215
DOB VIOLATION - ACTIVE
DOB NOW Safety (12)
IssuedViolationStatus
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
HPD (4) · C 1 · B 2 · A 0
IssuedClassViolationCorrect by
Apr 11, 2022I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Apr 11, 2022CApt 1B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 2nd APARTMENT FROM SOUTH AT WESTApr 17, 2022
Apr 11, 2022BApt 1B · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 2nd APARTMENT FROM SOUTH AT WESTMay 16, 2022
Apr 11, 2022BApt 1B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING ( APPROX 12 SQ.FT) IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 2nd APARTMENT FROM SOUTH AT WESTMay 16, 2022

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)