Bronx · Block 2925 · Lot 56 · 10456

1363 Fulton Avenue

3 floors · 80,700 sq ft · built 1956 · class W1 · owner of record: Nyc Department Of Education

33open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
168dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 80,700 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 778 days
Next cycle year 2028
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2925). Agency page

Dec 31, 2035
in 3334 days
Next due 2035
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-20 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (19)
IssuedViolationHearingBalance
Jul 7, 2026Construction CLASS - 2
REISSUE#35725166Y FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.BULKHEADS ARE MISSING PLASTER WATER DAMAGE.REM:COMPLY WITH CODE.
#35734482M
Aug 7, 2026
POP/IN-VIO
$0
Jul 7, 2026Construction CLASS - 2
REISSUE#35725107X OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OFOCCUPANCY OR BUILDING DEPT RECORDS OUTSIDE PLAY AREA OCCUPIED BY CARS.REM:COMPLY WITH CODE.
#35734481K
Aug 7, 2026
POP/IN-VIO
$0
Jul 7, 2026Construction CLASS - 2
REISSUE#35725104K EXIT DOOR NOT SELF-CLOSING PROPERLY 3RD FLOOR STAIR C AND EXIT DOOR 3R NOT CLOSING PROPERLY.REM:COMPLY WITH CODE.
#35734483Y
Aug 7, 2026
POP/IN-VIO
$0
Jul 7, 2026Construction CLASS - 2
REISSUE#35725108H FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.OBSERVED CRACKS IN ASPHALT AND DRAIN IS SINKING CAUSING TRIPPING HAZARD.REM:COMPLY WITH CODE.
#35734484X
Aug 7, 2026
POP/IN-VIO
$0
Aug 22, 2025Construction CLASS - 2
REISSUE: 35688726P DATE OF ISSUE: 08-30-24. OCCUPANCY CONTRARY TO THATALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDSAT OUTSIDE PLAY AREA BEING USED AS A PARKING LOT. REMEDY: DISCONTINUE
#35725107X
Sep 12, 2025
POP/IN-VIO
$0
Aug 22, 2025Construction CLASS - 2
REISSUE: 35688729K DATE OF ISSUE: 08-30-2024. EXIT DOOR NOT SELF-CLOSING PROPERLY AT THE TIME OF INSPECTION. OBSERVED AND NOTED AT 3RD FLOORST. WAY "B" 1 EXIT DOOR, 3RD FL. STAIRWAY 'C', 3RD FL. 1 EXIT DOOR, 3R
#35725104K
Sep 12, 2025
POP/IN-VIO
$0
Aug 22, 2025Construction CLASS - 2
REISSUE: 35688725N DATE OF ISSUE: 08-30-2024. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED CRACKS IN ASPHALT AT PLAY GROUND DRAINS ARE SINKING. REMEDY: REP
#35725108H
Sep 12, 2025
POP/IN-VIO
$0
Aug 22, 2025Construction CLASS - 2
REISSUE: 35688727R DATE OF ISSUE: 08-30-2024. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED AT STAIRCASE, B, E, D BULKHEAD SPALLING MISSING PLASTER, ALSO NO
#35725106Y
Sep 12, 2025
POP/IN-VIO
$0
Aug 30, 2024Construction CLASS - 2
REISSUE:35671872M-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.OBSERVED CRACKS IN ASPHALT AT PLAYGROUND DRAINS ARE SINKING.REM:COMPLY WITH CODE.
#35688725N
Nov 15, 2024
POP/IN-VIO
$0
Aug 30, 2024Construction CLASS - 2
REISSUE#35671870Z FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.MISSING PLASTER AT STAIRCASE B & E BULKHEAD SPALLING MISSING PLASTERALSO NOTED GYM CEILING WATER DAMAGED.REM:COMPLY WITH CODE.
#35688727R
Nov 15, 2024
POP/IN-VIO
$0
Aug 30, 2024Construction CLASS - 2
REISSUE#35671871K OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OFOCCUPANCY OR BUILDING DEPT.RECORDS.OUTDOOR PLAY AREA BEING USED AS A PARKING LOT.REM:COMPLY WITH CODE.
#35688726P
Nov 15, 2024
POP/IN-VIO
$0
Feb 15, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:OBSERVED AT STAIRCASE B & E BULKHEAD LEVEL SPALLING/MISSING PLASTER ALONG WINDOW WALLSAS A RESULT OF WATER PENETRATION.ADDITIONALLY AT 1ST FL GYMNASIUM CEIL
#35671870Z
Jun 16, 2023
POP/IN-VIO
$0
Feb 15, 2023Construction CLASS - 2
OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS.OBSERVED AT REAR OF SCHOOL BEHIND EXPO#3 OUTDOOR ASPHALT PAVED AREA BEING ACTUALLY USED AS A PARKING LOT WITH APPROX
#35671871K
Jun 16, 2023
POP/IN-VIO
$0
Feb 15, 2023Construction CLASS - 2
REISSUE#35644117P FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:OBSERVED FIREPROOF SELF CLOSING DOORS NOT CLOSING PROPERLY AT 3RD FLSTAIR E DOOR IS RACKED,& 3RD FL STAIR C DOOR IS WARPED.AT 2ND FL CORRI
#35671867H
Jun 16, 2023
POP/IN-VIO
$0
Feb 15, 2023Construction CLASS - 2
REISSUE#35542636J-EXIT DOOR NOT SELF CLOSING.OBSERVED EXTERIOR EXIT DOORS NOT SELF CLOSING AT EXIT 2 DOOR GETS STUCK AND SADDLE,CAFETERIA EXIT 10 NOT SELF CLOSING ONCE OPENED.AT GYMNASIUM EXIT 11 BROKEN CLOSER.
#35671868J
Jun 16, 2023
POP/IN-VIO
$0
Feb 15, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:OBSERVED AT REARPARKING LOT ASPHALT PAVED AREA SEVERAL UNEVEN SURFACES,CRACKED/MISSINGPATCHES OF ASPHAST MATERIAL.ASPHALT ALONG INGROUND DRAINS SINKING IN P
#35671872M
Jun 16, 2023
POP/IN-VIO
$0
Jan 28, 2021Construction CLASS - 2
REISSUE#35490702R EXIT DOOR NOT SELF-CLOSING,DOORS NOT WORKING ON FLS1,2,3 RM101,106,125,127,222,225,227,303,312,319,322,324.REPAIR/REPLACE DOOR.
#35542636J
May 7, 2021
POP/IN-VIO
$0
Mar 18, 2020Construction CLASS - 2
EXIT DOOR NOT SELF CLOSING. OBSERVED SELF CLOSING DOORS NOT WORKING ONFLOOR 1,2 & 3: ROOMS 101,106,125,127,222,225,227,303,308,312,319,322,324 & IN 3RD FL EXIT 5 IN FRONT OF CLASSROOM 321. REMEDY: REPAIR/REPLAC
#35490702R
Aug 7, 2020
POP/IN-VIO
$0
Mar 1, 2017Construction CLASS - 3
REISSUE VIOL #35148283H FOR OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BLDG DEPT RECORDS. NOTED: AUDITORIUM PROJECTION/AUDIO ROOM NOT IT'S USE AS ROOM 212,GUIDANCE COUNSELOR'S OFFICE.
#35235118J
Apr 21, 2017
POP/IN-VIO
$0
DOB (6)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06252
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06253
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#05463
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#05464
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#26968
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#26969
DOB VIOLATION - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 10:56 PM ET. BBL 2029250056.