Queens · Block 5135 · Lot 7501 · 11355

136-24 Maple Court

10 floors · 48 apartments · 68,158 sq ft · built 1986 · class RM · owner of record: Wisteria Grdns Condo

34open violations
$2,500ECB/OATH penalties owed
1HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 67 days
Annual
Annual boiler inspection (3 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-28 (Inspection Supervisor Review). Agency page

Dec 31, 2026
in 67 days
3 of 3 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 83 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $151,500 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 119 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 68,158 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 188 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 188 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1163 days
Next cycle year 2029
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5135). Agency page

Dec 31, 2035
in 3354 days
Next due 2035

Open violations

ECB / OATH (3) · $2,500 owed
IssuedViolationHearingBalance
Sep 4, 2024Construction CLASS - 1
28-323.8 AND RCNY 103-13(5). FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISIONS OF THE ADMINISTRATIVE CODE AFTER UNSAFE NOTIFICATION FILED BY QPSI UNS
#35686123R
Dec 17, 2024
IN VIOLATION
$2,500
May 23, 2022Boilers CLASS - 2
THE BOILER SAFETY VALVES HAVE THE DISCHARGE PIPES MANIFOLDED TOGETHER/THE BOILER CONDENSATE DRAINS ARE MISSING THE CONDENSATE NEUTRALIZER/THERE IS AN OPENING IN THE BOILER ROOM DOOR/, MAINTAIN BOILER; CORRECT V
#39063679R
Nov 15, 2022
IN VIOLATION
$0
Oct 18, 2006Elevators Non-Hazardous
05A01/ 17M07/ 17D06/ 28D06/ 59Q03/ 64Q03/ (05-A-01) CAR DOOR SLAMS OPEN. (17-M-07) GIB MISSING ON 2ND FL (17-D-06) DOOR GIBS LOOSE ON 1ST FL & BASEMENT FL (28-D-06) DOOR OPERATOR COVER LAYING ON CAR TOP.
#38161997P
Dec 5, 2006
WRITTEN OFF
$0
DOB (17)
IssuedViolationStatus
Nov 13, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00111
DOB VIOLATION - ACTIVE
Sep 9, 2024CONSTRUCTION
RE: PARTIAL VACATE ORDER DUE TO UNSAFE CONDITIONS INCLUDING DETSPALLI NDERSIDE OF THE GROUND FLOOR SLAB @ MULTIPLE LOCATIONSREMEDY,IMMED.COR D VACATE ENTIRE PARKING GARAGE
#PS40702AB
DOB VIOLATION - ACTIVE
Sep 9, 2024CONSTRUCTION
PARTIAL VACATE ORDER DUE TO UNSAFE CONDITIONS INCLUDING DETERIORATED SPALLING AT THE UNDERSIDE OF THE GROUND FLOOR SLAB @ MULTIPLE LOCATIONS. THESE CONDITIONS HAVE MADE THE ENTIRE PARKING GARAGE STRUCTURE UNABLE TO BE OCCUPIED. REMEDY, IMMEDIATELY CORDON OFF AND VACATE ENTIRE PARKING GARAGE
#FA4070AB
DOB VIOLATION - ACTIVE
Sep 4, 2024CONSTRUCTION
EMERGENCY WORK ORDER DUE DEFECTIVE PARKING STRUCTURE.NOTE:AT THE TIME OF INSPECTION OBSERVED SPALLING AND CRACKED CONCRETE SLAB/BEAMS AT MULTIPLE LOCATION. REMEDY:IMMEDIATELY PROVIDE SAFETY MEASURE TO SECURE/PROTECT THE PUBLIC AND REMOVE ALL LOOSE MATERIALS
#FA0701AB
DOB VIOLATION - ACTIVE
May 31, 2018NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
#01187
DOB VIOLATION - ACTIVE
Nov 2, 2015FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00643
DOB VIOLATION - ACTIVE
May 2, 2015FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#01389
DOB VIOLATION - ACTIVE
May 30, 2014(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
#06868
DOB VIOLATION - ACTIVE
May 30, 2014(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
#06867
DOB VIOLATION - ACTIVE
May 30, 2014(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
#06869
DOB VIOLATION - ACTIVE
Nov 13, 2012ELEVATOR

#452939/9027
DOB VIOLATION - ACTIVE
Nov 13, 2012ELEVATOR

#452941/9027
DOB VIOLATION - ACTIVE
Nov 13, 2012ELEVATOR

#452940/9027
DOB VIOLATION - ACTIVE
May 3, 2012FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#02978
DOB VIOLATION - ACTIVE
Jan 1, 2012FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#02697
DOB VIOLATION - ACTIVE
Feb 27, 2001LOCAL LAW 62/91 - BOILERS

#28151
DOB VIOLATION - ACTIVE
Feb 27, 2001LOCAL LAW 62/91 - BOILERS

#28152
DOB VIOLATION - ACTIVE
DOB NOW Safety (11)
IssuedViolationStatus
Nov 13, 2024AEUHAZ FTC-AEU-HAZ
Active
May 31, 2018Facades FISPNRF
FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
Active
Nov 2, 2015Benchmarking - LL84 FTF-EN-BENCH
Active
May 2, 2015Benchmarking - LL84 FTF-EN-BENCH
Active
May 30, 2014Elevators ACC1
Active
May 30, 2014Elevators ACC1
Active
May 30, 2014Elevators ACC1
Active
May 3, 2012Benchmarking - LL84 FTF-EN-BENCH
Active
Jan 1, 2012Benchmarking - LL84 FTF-EN-BENCH
Active
Feb 27, 2001Boiler LL6291
Active
Feb 27, 2001Boiler LL6291
Active
HPD (3) · C 1 · B 1 · A 1
IssuedClassViolationCorrect by
May 7, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 10, 2026
Jun 11, 2024BApt 3E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM AT BUILDING VESTIBULE TO RETURN BUZZER AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTHJul 16, 2024
Dec 7, 2009C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING AT PUBLIC HALL, 1st STORYDec 13, 2009

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 4:30 PM ET. BBL 4051357501.

Look up another building