10 floors · 48 apartments · 68,158 sq ft · built 1986 · class RM · owner of record: Wisteria Grdns Condo
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 67 days | Annual |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-28 (Inspection Supervisor Review). Agency page | Dec 31, 2026 in 67 days | 3 of 3 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 83 days | Annual |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $151,500 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 119 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 68,158 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1163 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5135). Agency page | Dec 31, 2035 in 3354 days | Next due 2035 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 4, 2024 | Construction CLASS - 1 28-323.8 AND RCNY 103-13(5). FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISIONS OF THE ADMINISTRATIVE CODE AFTER UNSAFE NOTIFICATION FILED BY QPSI UNS #35686123R | Dec 17, 2024 IN VIOLATION | $2,500 |
| May 23, 2022 | Boilers CLASS - 2 THE BOILER SAFETY VALVES HAVE THE DISCHARGE PIPES MANIFOLDED TOGETHER/THE BOILER CONDENSATE DRAINS ARE MISSING THE CONDENSATE NEUTRALIZER/THERE IS AN OPENING IN THE BOILER ROOM DOOR/, MAINTAIN BOILER; CORRECT V #39063679R | Nov 15, 2022 IN VIOLATION | $0 |
| Oct 18, 2006 | Elevators Non-Hazardous 05A01/ 17M07/ 17D06/ 28D06/ 59Q03/ 64Q03/ (05-A-01) CAR DOOR SLAMS OPEN. (17-M-07) GIB MISSING ON 2ND FL (17-D-06) DOOR GIBS LOOSE ON 1ST FL & BASEMENT FL (28-D-06) DOOR OPERATOR COVER LAYING ON CAR TOP. #38161997P | Dec 5, 2006 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 13, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00111 | DOB VIOLATION - ACTIVE |
| Sep 9, 2024 | CONSTRUCTION RE: PARTIAL VACATE ORDER DUE TO UNSAFE CONDITIONS INCLUDING DETSPALLI NDERSIDE OF THE GROUND FLOOR SLAB @ MULTIPLE LOCATIONSREMEDY,IMMED.COR D VACATE ENTIRE PARKING GARAGE #PS40702AB | DOB VIOLATION - ACTIVE |
| Sep 9, 2024 | CONSTRUCTION PARTIAL VACATE ORDER DUE TO UNSAFE CONDITIONS INCLUDING DETERIORATED SPALLING AT THE UNDERSIDE OF THE GROUND FLOOR SLAB @ MULTIPLE LOCATIONS. THESE CONDITIONS HAVE MADE THE ENTIRE PARKING GARAGE STRUCTURE UNABLE TO BE OCCUPIED. REMEDY, IMMEDIATELY CORDON OFF AND VACATE ENTIRE PARKING GARAGE #FA4070AB | DOB VIOLATION - ACTIVE |
| Sep 4, 2024 | CONSTRUCTION EMERGENCY WORK ORDER DUE DEFECTIVE PARKING STRUCTURE.NOTE:AT THE TIME OF INSPECTION OBSERVED SPALLING AND CRACKED CONCRETE SLAB/BEAMS AT MULTIPLE LOCATION. REMEDY:IMMEDIATELY PROVIDE SAFETY MEASURE TO SECURE/PROTECT THE PUBLIC AND REMOVE ALL LOOSE MATERIALS #FA0701AB | DOB VIOLATION - ACTIVE |
| May 31, 2018 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 #01187 | DOB VIOLATION - ACTIVE |
| Nov 2, 2015 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00643 | DOB VIOLATION - ACTIVE |
| May 2, 2015 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #01389 | DOB VIOLATION - ACTIVE |
| May 30, 2014 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST #06868 | DOB VIOLATION - ACTIVE |
| May 30, 2014 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST #06867 | DOB VIOLATION - ACTIVE |
| May 30, 2014 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST #06869 | DOB VIOLATION - ACTIVE |
| Nov 13, 2012 | ELEVATOR #452939/9027 | DOB VIOLATION - ACTIVE |
| Nov 13, 2012 | ELEVATOR #452941/9027 | DOB VIOLATION - ACTIVE |
| Nov 13, 2012 | ELEVATOR #452940/9027 | DOB VIOLATION - ACTIVE |
| May 3, 2012 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #02978 | DOB VIOLATION - ACTIVE |
| Jan 1, 2012 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #02697 | DOB VIOLATION - ACTIVE |
| Feb 27, 2001 | LOCAL LAW 62/91 - BOILERS #28151 | DOB VIOLATION - ACTIVE |
| Feb 27, 2001 | LOCAL LAW 62/91 - BOILERS #28152 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 13, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| May 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017 | Active |
| Nov 2, 2015 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| May 2, 2015 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| May 30, 2014 | Elevators ACC1 | Active |
| May 30, 2014 | Elevators ACC1 | Active |
| May 30, 2014 | Elevators ACC1 | Active |
| May 3, 2012 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jan 1, 2012 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Feb 27, 2001 | Boiler LL6291 | Active |
| Feb 27, 2001 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 7, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 10, 2026 |
| Jun 11, 2024 | B | Apt 3E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM AT BUILDING VESTIBULE TO RETURN BUZZER AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH | Jul 16, 2024 |
| Dec 7, 2009 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING AT PUBLIC HALL, 1st STORY | Dec 13, 2009 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 4:30 PM ET. BBL 4051357501.