14 floors · 142,250 sq ft · built 2024 · class H2 · owner of record: Jfk Fiona 34 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | Feb 21, 2027 in 99 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 142,250 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 412 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 12099). Agency page | Dec 31, 2029 in 1143 days | Next due 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 28, 2026 | Construction CLASS - 2 DURING MY INSPECTION OF AN ACTIVE 14-STORY. I OBSERVED, ON THE GROUND LEVEL, EXPOSURE: ONE SCATTERED MATERIAL NOT ORGANIZED IN A SAFE MANNER. THE SIDEWALK SHED-IN-PLACE UPRIGHT POSTS' BASES WERE COVERED AND NOT #39558518K | Nov 10, 2026 PENDING | $1,250 |
| Jul 1, 2026 | Construction CLASS - 2 ACTIVE 14-STORY NEW BUILDING SITE, TEMPORARY PLATFORMS WERE INSTALLED AT THE STAIRWAY FROM THE BASEMENT TO THE FIRST FLOOR AND AT THE 7TH-FLOOR STAIRWAY. UPON REQUEST, NO PE DESIGN DRAWINGS WERE PROVIDED. THIS #39556081H | Apr 6, 2027 | $1,250 |
| Jul 1, 2026 | Unknown CLASS - 1 BC3314.1AT THE TIME OF INSPECTION OF AN ACTIVE 14-STORY NEW BUILDING SITE, WORKERS WERE PERFORMING FACADE OPERATIONS ON A SUPPORTED PIPE SCAFFOLD AT EXP# 1. THE SCAFFOLD WAS NOT MAINTAINED, WITH MULTIPLE MISSIN #39556080X | Apr 6, 2027 | $5,000 |
| Mar 14, 2026 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION FOR COMPLIANCE WORK WITH AFTER HOURS PERMIT ISSUED I OBSERVED WORK BEING PERFORMED ON INSTALLATION/MODIFICATION OF SUPPORTED SCAFFOLD AT EXP#2 INSTALLATION OF PLANKED PLATFORMS(CONT #39551729Z | Dec 8, 2026 | $1,250 |
| Dec 21, 2025 | Construction CLASS - 2 AT THE TIME OF MY INSPECTION OF A 14-STORY NEW BUILDING, I OBSERVED CONSTRUCTION FENCING AT EXPOSURES 1 AND 3,4, WAS NOT MAINTAINED, WITH MISSING SECTIONS. THIS CONDITION CREATED A HAZARD TO WORKERS AND THE PUB #39548360K | Apr 6, 2027 | $1,000 |
| Dec 21, 2025 | Unknown CLASS - 1 BC 3314.1, 3314.8 AT THE TIME OF INSPECTION OF A 14-STORY NEW BUILDING, PIPE SCAFFOLDING WAS OBSERVED AT EXP# 1,2, 3, AND 4 WITH LOOSE PLANKS, MISSING PINS, DEBRIS NETTING WITH LARGE OPENINGS, CREATING A HAZAR #39548359N | Apr 6, 2027 | $5,000 |
| Dec 21, 2025 | Unknown CLASS - 1 14-STORY BUILDING, I OBSERVED AN ACTIVE PARKING LOT AT EXP# 2& DRIVEWAY AT EXP# 4 IN CLOSE PROXIMITY TO THE STRUCTURE WITHOUT REQUIRED OVERHEAD PROTECTION OR A CONTROLLED ACCESS ZONE. THIS CONDITION CREATES A H #39548361M | Apr 6, 2027 PENDING | $10,000 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 28, 2026 | ECB | Construction: DURING MY INSPECTION OF AN ACTIVE 14-STORY. I OBSERVED, ON THE GROUND LEVEL, EXPOSURE: ONE SCATTERED MATERIAL NOT ORGANIZED IN A SAFE MANNER. THE SIDEWALK SHED-IN-PLACE UPRIGHT POSTS' BASES WERE COVERED AND NOT | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 9:37 AM ET. BBL 4120990034.