| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 61 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 61 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-15 (Payment Verification In Progress). Agency page | Dec 31, 2026 in 61 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 77 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 305 days | Registered through 2027-09-01 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 8, 2026 | Boilers CLASS - 2 FOUND WEIL MCLAIN OIL FIRED BOILER MODEL#480 WITH CORRODED RETURN LINES ON BACK OF BOILER, COMBUSTABLE STORAGE TO BE REMOVED ,BOTH BOILER ROOM DOORS NOT SELF CLOSING. SHUT OFF VALVE ON OIL RETURN LINE TO BE REM #39207316H | Dec 18, 2026 PENDING | $1,250 |
| Jul 26, 2021 | Boilers CLASS - 2 FOUND EXPOSED WIRES, CORRODED RETURN LINES ON BACK OF BOILER, AIR GAP AND DISCHARGE PIPE MISSING AT BACK FLOW PREVENTER, CORRODED FITTING ON COLD WATER LINE, VALVE ON OIL LINE MISSING PLUG, DAR KIT MISSING ON B #39044942L | Sep 17, 2021 DEFAULT | $0 |
| May 19, 2012 | Construction CLASS - 1 B101- INSTALLED NEW WEIL MCLAIN SERIES 80 W/CARLIN BURNER 201 CRD STEAM BOILER OIL FIRED NO PERMIT ON FILE BOILER ONLY APP 5 MONTHS OLD. WORK W/O A PERMIT. BOILER NOT IN USE FOR SUMMER. #32071973N | Dec 14, 2012 WRITTEN OFF | $0 |
| May 19, 2012 | Boilers CLASS - 2 B254,16,36,50A,B,C,D. 50A- UNREGISTERED BOILER. 50B- INSULATION MISSING ON HEADER. 50C- NO CLEAN OUT AT BASE OF CHIMNEY. 50D- RELIEF VALVE ON HWH DISCHARGE MUST BE EXTENDED TO BE 8" OFF FLR. #32071974P | Dec 21, 2012 WRITTEN OFF | $0 |
| Sep 20, 2011 | Boilers CLASS - 2 B254 15 16 21C 32A 34B 48A 50A 50B. 50A-DEFECTIVE AUTO CONTROLS. 50B-OIL LINES NOT COVERED. #32071305H | Dec 2, 2011 IN VIOLATION | $0 |
| Oct 5, 2009 | Boilers CLASS - 2 B254. 16.40.50A.50B.50C.50D.50E.50F 50A DAR KIT MISSING ON OIL BURNER 50B MUST HAVE CHECK VALVE FOR BACKFLOW PREVENTOR WHERE FEED GOES INTRORETURN 50C NEED BRASS PIGTAIL FOR PRESSURE GAUGE D SAFETY VALVE MUST B #32067179Y | Feb 19, 2010 IN VIOLATION | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 28, 2026 | B | § 27-2005 ADM CODE PROVIDE UNLOCKABLE SLIDE BOLT AND LOCK OR HOOK ON ROOF DOOR THAT ALLOWS RE ENTRY FROM ROOF TO PUBLIC HALL AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 5th STORY | Nov 2, 2026 |
| Sep 21, 2026 | C | Apt 1 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 21, 2026 |
| Sep 21, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM | Sep 27, 2026 |
| Sep 21, 2026 | B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE GARBAGE WITH GARBAGE BINS STORED AT FIRE PASSAGE WAY | Oct 26, 2026 |
| Jun 23, 2026 | A | Apt 6 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Sep 26, 2026 |
| Jun 23, 2026 | B | Apt 6 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jul 28, 2026 |
| Jan 29, 2026 | C | Apt 7 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK TO DOOR LEADING TO FIRE ESCAPE IN THE 3rd ROOM FROM NORTH LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 4, 2026 |
| Aug 4, 2025 | B | Apt 10 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH WINDOW, 1ST WINDOW FROM NORTH AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 10, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Sep 8, 2025 |
| Aug 4, 2025 | B | Apt 10 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH WINDOW AT NORTH WALL IN THE BATHROOM LOCATED AT APT 10, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Sep 8, 2025 |
| Jun 3, 2025 | B | Apt 9 · 28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AN | Jul 8, 2025 |
| May 16, 2025 | C | Apt 4 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jun 11, 2025 |
| Nov 22, 2024 | C | Apt 1 · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 28, 2024 |
| May 13, 2024 | B | Apt 5 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT 1ST AND 2ND LOWER WINDOW SASH AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 17, 2024 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 8, 2026 | ECB | Boilers: FOUND WEIL MCLAIN OIL FIRED BOILER MODEL#480 WITH CORRODED RETURN LINES ON BACK OF BOILER, COMBUSTABLE STORAGE TO BE REMOVED ,BOTH BOILER ROOM DOORS NOT SELF CLOSING. SHUT OFF VALVE ON OIL RETURN LINE TO BE REM | Open |
| Sep 28, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT ROOF DOOR AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 5th STORY | Closed |
| Sep 28, 2026 | HPD B | § 27-2005 ADM CODE PROVIDE UNLOCKABLE SLIDE BOLT AND LOCK OR HOOK ON ROOF DOOR THAT ALLOWS RE ENTRY FROM ROOF TO PUBLIC HALL AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 5th STORY | Open |
| Sep 21, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 21, 2026 | HPD C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM | Open |
| Sep 21, 2026 | HPD B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE GARBAGE WITH GARBAGE BINS STORED AT FIRE PASSAGE WAY | Open |
| Sep 21, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |