Brooklyn · Block 1850 · Lot 47 · 11216

1349 Fulton Street

3 floors · 2 apartments · 3,000 sq ft · built 1910 · class S2 · owner of record: Bawabeh Brothers No. 2 Llc

19open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
787dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 56 days
Keep the report on file (not filed with DOB)
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 300 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 787 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-01 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (4)
IssuedViolationHearingBalance
Feb 17, 2010Boilers CLASS - 3
50A/50C/50B/50B/50D/COLUMBIA V.T. BOILER, 10HP,NB135771,OIL 1993/50A-CORRODED & DISLOCATED FIREPROOF MATERIAL @ BOILER RM CEILING REPLACE SHEET METAL/50B-BOILER RM FIRE DOOR SWING BLOCKED @ GROUND LEVEL.REMOVE
#32067500L
Apr 12, 2010
DEFAULT
$0
Mar 31, 2008Boilers Non-Hazardous
50A50B6A48B. COLUMBIA VT BER 10HP NB 135771 OIL FD 1993. 50A IMPROPER ARRANGEMENT OF THE BLOW DOWN VALVES. INSPEC A SCREW TYPE "SLOW" VALVE @ THE OUTLET END OF THE BLOWDOWN LINE. 6A SLOW LEAK @ SAFETY VALVE.
#32056203L
May 19, 2008
IN VIOLATION
$0
Oct 22, 2004Boilers Non-Hazardous
50A/51 6A/48AB LOW PRESSURE STEAM HEATING BOILER SERVING APARTMENTS. 50A) BOILER IN OPERATION WITH NEWLY/PARTIALLY INSTALLED FLUE PIPE NOT CONNECTED TO CHIMNEY BASE. 51 HAZARDOUS OPERATING CONDITION NOTED.
#32046492H
Dec 6, 2004
IN VIOLATION
$0
Jul 21, 1997Boilers Non-Hazardous
36
#32015005J
Sep 8, 1997
WRITTEN OFF
$0
DOB (6)
IssuedViolationStatus
Jun 30, 2023HIGH PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION
#02256
DOB VIOLATION - ACTIVE
Jun 20, 2023HIGH PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL HGH PRESSURE INSPECTION
#00959
DOB VIOLATION - ACTIVE
Jun 20, 2023HIGH PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 INTERNAL HGH PRESSURE INSPECTION
#02170
DOB VIOLATION - ACTIVE
Mar 16, 2020HIGH PRESSURE BOILER
VIOLATION ISSUED - FAILURE TO FILE 2017 EXTERNAL HIGH PRESSURE BOILER INSPECTION
#00767
DOB VIOLATION - ACTIVE
Mar 16, 2020HIGH PRESSURE BOILER
VIOLATION ISSUED - FAILURE TO FILE 2017 INTERNAL HIGH PRESSURE BOILER INSPECTION
#00806
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#24582
DOB VIOLATION - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
Nov 14, 2023Boiler FTC-BE-INT-HP
Violation Issued-Failure To File 2021 Internal Inspection Affirmation of Correction for HP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-HP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for HP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-HP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for HP Device
Active
Jun 30, 2023Boiler HBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION
Active
Jun 20, 2023Boiler HBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL HGH PRESSURE INSPECTION
Active
Jun 20, 2023Boiler HBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 INTERNAL HGH PRESSURE INSPECTION
Active
Mar 16, 2020Boiler HBLVIO
VIOLATION ISSUED - FAILURE TO FILE 2017 EXTERNAL HIGH PRESSURE BOILER INSPECTION
Active
Mar 16, 2020Boiler HBLVIO
VIOLATION ISSUED - FAILURE TO FILE 2017 INTERNAL HIGH PRESSURE BOILER INSPECTION
Active
HPD (1) · C 0 · B 1 · A 0
IssuedClassViolationCorrect by
May 12, 2022B§ 185, 240 M/D LAW PROPERLY FIRE RETARD IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT THE CELLAR CEILING ..Jun 16, 2022

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 5, 2026, 9:50 PM ET. BBL 3018500047.