Bronx · Block 2830 · Lot 17 · 10456

1340 Sheridan Avenue

4 floors · 22,400 sq ft · built 1925 · class W1 · owner of record: Nyc Department Of Education

15open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (4 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-20 (Accepted). Agency page

Dec 31, 2026
in 47 days
2 of 4 without an accepted 2026 report yet

Open violations

ECB / OATH (8)
IssuedViolationHearingBalance
Mar 27, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3; 27-345. NOTED: IN ELECTRIC METER ROOM THERE WAS FIRE STOPPING MISSING AROUND PIPES GOING THRU "CMU" BLOCKS ABOVE DOOR. REMED
#35722423Y
Apr 10, 2026
POP/IN-VIO
$0
Mar 27, 2026Construction CLASS - 2
RE-ISSUE #35719920H. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND AND PUBLIC CORRIDORSPER BC 1006.1; 27-381. NOTED: EMERGENCY LIGHTS ON MEZZANINE LEVEL DID
#35722420Z
Apr 10, 2026
POP/IN-VIO
$0
Mar 27, 2026Construction CLASS - 2
RE-ISSUE #35719918Z. FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: AT THE TIME OF INSPECTION OBSERVED WATER PUDDLES IN GAS METER ROOM DUE TO WATER PENETRATION THRU WALLS. REMEDY: MAINTAIN EXTERI
#35722421K
Apr 10, 2026
POP/IN-VIO
$0
Mar 27, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: FIRE-PROOF NEAR(203) DOES NOT SELF-CLOSE PROPERLY. CLASSROOM DOORS DO NOT SELF-CLOSE PROPERLY AT, 1ST FLR-RM #106, 104. REMEDY: REPAIR AND/OR REPLAC
#35722422M
Apr 10, 2026
POP/IN-VIO
$0
May 22, 2025Construction CLASS - 2
REISSUE #35683966R DATE OF ISSUE: 07-26-2024. FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. AT THE TIME OF INSPECTION OBSERVED AND NOTED WATER PENETRATION ON THE SHERIDAN AVEUE SIDE CAUSING SPALLING AN
#35719918Z
Jul 11, 2025
POP/IN-VIO
$0
May 22, 2025Construction CLASS - 2
REISSUE #35682965P DATE OF ISSUE: 07-26-2024. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGESAND PUBLIC CORRIDORS PER BC 1006.1; 27-381. AT THE TIME OF INSPECTION
#35719920H
Jul 11, 2025
POP/IN-VIO
$0
Jul 26, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALL OR APPURTENANCES.NOTED:WATER PENETRATION ON THE SHERIDAN AVE SIDE CAUSING SPALLING AND PEELING IN THE GAS METER ROOM IN THE BASEMENT.REM:MAINTAIN EXTERIOR BUILDING WALL.
#35682966R
Oct 4, 2024
POP/IN-VIO
$0
Jul 26, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS.NOTED:AUDITORIUM LIGHTS NOTWORKING WHEN TESTED TOTAL#7 LIGHTS LOWER LEVEL EM LIGHTS#15 AND 14 NOT
#35682965P
Oct 4, 2024
POP/IN-VIO
$0
DOB (1)
IssuedViolationStatus
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#30227
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 10:13 PM ET. BBL 2028300017.

Look up another building