| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 56 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-25 (Accepted). Agency page | Dec 31, 2026 in 56 days | 1 of 2 without an accepted 2026 report yet |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 787 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 9, 2019 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #32097847H ISSUED ON 01-30-2019,AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1 RCNY 102-01.AN ACCEPTIBLE CERTIFICATE #37016942K | Nov 24, 2020 DEFAULT | $3,125 |
| Jan 30, 2019 | Boilers CLASS - 2 B254,50A,50B,50C,50D,50E,50F. BURNHAM BOILER MODEL UNKNOW. 50A-MISS ING RATINGS PLATE; 50B- MISSING INSULATION; 50C- MISSING CHIMNEY BASE CLEANOUT 50D-MISSING DOOR SIGNS; 50E-GAUGE OF FLUE PIPE IMPROPER; 50F- #32097847H | Apr 9, 2019 STIPULATION/IN-VIO | $5 |
| May 25, 2018 | Boilers CLASS - 2 36,15,4A,24B,38,50A,50B,50C. B254-36- FOUND BURNHAM GAS FIRED BOILER NOT REGISTERED; 50A- MANUFACTURERS RATING TAG MISSING; B-NO CLEAN OUT ON CHIMNEY BASE; C-FLUE PIPE NOT SEALED TO CHIMNEY BASE. REGISTER THE #32096863N | Jul 10, 2018 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 1, 2009 | LOCAL LAW 62/91 - BOILERS #25596 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 1, 2009 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 17, 2008 | A | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEILING THROUGHTOUT CELLAR. | Sep 20, 2008 |
| Jun 17, 2008 | A | § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING 2ND STY. SOUTH APT. REAR EAST BEDROOM IN CLOSET AND AT FRONT OF CLOSET. | Sep 20, 2008 |
| Jun 17, 2008 | A | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE WEST WALL UNDER KITCHEN SINK AT 2ND STY. NORTH APT. | Sep 20, 2008 |
| Jun 17, 2008 | A | § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING 2ND STY. NORTH APT. 3 FROM FRONT WEST ROOM AT WEST. | Sep 20, 2008 |
| Jun 17, 2008 | A | § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE HANDRAIL, BANNISTER SOUTH SECTION 1ST TO 2ND STY. HALL STAIR, PRIVATE HALL. | Sep 20, 2008 |
| Jun 17, 2008 | B | § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE STAIR TREAD, 4TH TREAD UP. ST TO 2ND STY. PRIVATED HALL TO 2ND STY. SOUTH APT. | Jul 22, 2008 |
| Jun 17, 2008 | B | § 27-2027 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING PUBLIC SIDEWALK NEAR CURB AND STREET DRAIN. | Jul 22, 2008 |
| Jun 17, 2008 | B | § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 2ND STY. NORTH APT. BATHTROOM AND KITCHEN D22050-H. | Jul 22, 2008 |
| Jun 17, 2008 | C | § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 2ND STY. FRONT APT. ER-1. | Jun 23, 2008 |
| Jun 17, 2008 | B | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FLOOR AT FRONT ENTRANCE VESTIBULE. | Jul 22, 2008 |
| Jun 17, 2008 | B | § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING WALL LIGHT FIXTURES AT WEST ENTRANCE DOOR. | Jul 22, 2008 |
| Jun 17, 2008 | B | § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING LIGHT BULB AT WEST ENTRANCE VESTIBULE CEILING FIXTURE. | Jul 22, 2008 |
| Jun 17, 2008 | C | § 27-2005 ADMIN. CODE: PROVIDE TEMPORARY SECURING - ALL ACCESSIBLE OPENINGS (ER-1). | Jun 23, 2008 |