Brooklyn · Block 942 · Lot 7503 · 11217

133 Sterling Place

21 apartments · 39,019 sq ft · built 2007 · class R4 · owner of record: The Vermeil Condominium

14open violations
$1,562ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 39,019 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing

Open violations

ECB / OATH (1) · $1,562 owed
IssuedViolationHearingBalance
Mar 16, 2021Elevators CLASS - 2
PROVIDE MISSING IN CASE OF FIRE SIGNS. REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. MISSING CAR DOOR GIB. REMOVE NON ELEVATOR EQUIPMENT FROM MACHINE ROOM. EXPIRED FIRE EXTINGUISHER
#39037667K
Jan 5, 2022
DEFAULT
$1,562
DOB (2)
IssuedViolationStatus
Aug 2, 2019FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#01004
DOB VIOLATION - ACTIVE
May 2, 2019FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#01879
DOB VIOLATION - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
Sep 6, 2019Elevators ACC1
Active
Aug 2, 2019Benchmarking - LL84 FTF-EN-BENCH
Active
May 2, 2019Benchmarking - LL84 FTF-EN-BENCH
Active
Nov 14, 2016Elevators ACC1
Active
Oct 1, 2012Elevators EVCAT1
Active
Dec 13, 2011Elevators EVCAT1
Active
Oct 8, 2010Elevators VCAT1
Active
HPD (4) · C 0 · B 4 · A 0
IssuedClassViolationCorrect by
Apr 13, 2015BApt 1D · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHEETROCKS AT ALL THE WALLS IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1D LOWER LEVEL, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 18, 2015
Apr 13, 2015BApt 1D · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1D LOWER LEVEL, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 18, 2015
Apr 13, 2015BApt 1D · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 1D, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 18, 2015
Aug 9, 2010BSECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE COMPOSITE MATERIAL ON TOP OF ROOF CORNICE AT EAST AND NORTHSIDE OF BUILDING...... (ACCESS THROUGH APT 5A)Sep 13, 2010

Check the agency records