Brooklyn · Block 578 · Lot 4 · 11231

133 Dwight Street

2 floors · 5,500 sq ft · built 1931 · class E9 · owner of record: 133 Dwight St. Realty, Llc

15open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
68dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 68 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)

Open violations

ECB / OATH (9)
IssuedViolationHearingBalance
Jan 19, 2007Unknown Non-Hazardous
OCCUPANCY IN MANUFACTURING DISTRICT M1-1 IN CONSISTENT W/ THAT ALLOWEDBY THE C OF O # 182073. ILLEGAL OCCUPANCY NOTED : 2ND FL FRONT LEGAL OFFICES NOW CONVERTED TO A CLASS 'A' APT. W/ KITCHEN W/ GAS STOVE, 3PC
#34545229J
Apr 16, 2007
IN VIOLATION
$0
Jan 19, 2007Zoning Hazardous
ILLEGAL USE IN A MANUFACTURING DISTRICT.NOTED:2FL FRONT OF BLDG IS A CLASS A APT.COMPLETE W/GAS STOVES,3PC BATHROOM(SINK,TOILET,TUB/SHOWER)BEDROOM,LIVINGROOM.REMEDY:DISCONTINUE ILLEGAL USE
#34560352K
Apr 16, 2007
WRITTEN OFF
$0
Jan 19, 2007Unknown Hazardous
WORK W/O A PERMIT IN A MANUFACTURING DISTRICT FOR RESIDENTIAL USE.NOTE:PARTITION WALLS ERECTED ON 2FL FRONT TO CREATE 2 ROOMS.REMEDY:OBTAIN PERMIT OR RESTORE TO PRIOR LEGAL CONDITION.
#34560353M
Apr 16, 2007
IN VIOLATION
$0
Jan 19, 2007Unknown Non-Hazardous
PLUMBING WORK W/O A PERMIT IN MANUFACTURING DISTRICT M 1-1 FOR RESIDENTIAL USE. WORK NOTED:2ND FL FRONT INSTALLED WATER & WASTE LINES FOR 3 PC BATH(SINK,TOILET,TUB/SHOWER)& RESIDENTIAL SINK.2ND FL REAR OF HALLW
#34545230R
Apr 16, 2007
IN VIOLATION
$0
Jul 24, 2006Construction Hazardous
FAIL TO MAINTAIN EXT BLDG WALL-HAZARD. NOTE:SECT BLDG BRICK FACADE HASMAJ CRACK,SEPARATE &BLUG @N FACE.DEFECT RUN FRM COPPING STONE @PARAPETWALL TO LENTIL @FIRE ESCAPE DR. CRACKS RANGE APPROX 2"W X 1/4"W.
#34532009P
Oct 2, 2006
WRITTEN OFF
$0
May 24, 2001Construction Non-Hazardous
FAILURE TO MAINTAIN.DEFECTS ARE:EXTERIOR BUILDING WALL HAS VERTICAL CRACKS FROM ROOF TO SECOND STORY IN VARIOUS AREAS.REMEDY:MAKE ALL NECESSARY REPAIRS ACCORDING TO BUILDING DEPT REGULATIONS.
#34290487K
Jul 9, 2001
WRITTEN OFF
$0
Dec 11, 1997Construction Hazardous
FAILURE TO MAINTAIN. DEFECTS ARE: EXTERIOR EAST REAR WALL HAS ERECTED CRACK IN STRUCTURE AND SEVERAL CRACKS ON WEST FRONT WALL. REMEDY: MAKE ALL NECESSARY REPAIRS ACCORDING TO BUILDING DEPT. REGULATION IN A SA
#34168060M
Jan 26, 1998
WRITTEN OFF
$0
Mar 15, 1993Construction Hazardous
WORK WITHOUT A PERMIT.HAZARDOUS ENTIRE ROOF HAS BEEN DEMO ED AND RE-ERECTED.SUCH WAS WOOD BEAM ROOFING NOW STRUSS ROOF.ROOF HAS COLLAPSED. (IMMEDIATE VACATE.)REMEDY:MAKE ALL NECESSARY SHORING TO RELIEF THE IMM
#34088858L
May 17, 1993
WRITTEN OFF
$0
Mar 15, 1993Construction Non-Hazardous
FAILURE T MAINTAIN INTERIOR EAST REAR WALL 1 INCH CRACK RUNNING FROM GROUND TO ROOF WHICH INDICATE BUCKLING OUT OF MAIN SUPPORT BRICK COLUMN WHERE MAIN CENTER CONNECT INTO CAUSING OF 2ND FLOOR STRY 2ND FLOOR US
#34088860K
Jun 7, 1993
WRITTEN OFF
$0
DOB (5)
IssuedViolationStatus
Jul 25, 2006IMMEDIATE EMERGENCY

#143/06
DOB VIOLATION - ACTIVE
May 24, 2001CONSTRUCTION

#06MC01
DOB VIOLATION - ACTIVE
Dec 11, 1997CONSTRUCTION
FAILURE TO MAINTAIN DEFECT TO EXTERIOR EAST REAR WALL
#06HS04
DOB VIOLATION - ACTIVE
Dec 11, 1997CONSTRUCTION
FAILURE TO MAINTAIN DEFECTS IN EXTERIOR
#06HS04
DOB VIOLATION - ACTIVE
Oct 23, 1996CONSTRUCTION

#06H02
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 12:54 PM ET. BBL 3005780004.

Look up another building