8 floors · 22,880 sq ft · built 1900 · class H3 · owner of record: B.K.B.W. Realty Corp.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $477,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2028 in 464 days | No Cycle 10 report on record yet |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1143 days | Next cycle year 2029 |
| Annual boiler inspection (5 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-08 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 11, 2026 | Unknown CLASS - 1 ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED ON THE GROUND FL KITCHEN ELECTRIC OVEN / FOOD WARMER INSTALLED WITH DISCONNECT SW 3/4 PIPE COMING FROM KITCHEN PANEL. CHECKED BIS / DOB NOW NO PERMIT ON FILE ALL WORK #39200102K | Oct 15, 2026 ADMIT/IN-VIO | $0 |
| Aug 11, 2026 | Unknown CLASS - 2 FAILURE TO PROTECT CONDUCTOR(S) AGAINST OVERCURRENT. OBSERVED IN BOTH ELEVATOR MACHINE RMS THAT THE OVERCURRENT PROTECTION IS INCORRECT BOTH ARE FUSED AT 100 AMP #6 AWG SHALL BE FUSED AT THE PROPER OVERCURRENT #39200101Z | Oct 15, 2026 ADMIT/IN-VIO | $0 |
| Aug 11, 2026 | Elevators CLASS - 2 CLASS 2: 1. MAIN LINE BOX COVER CAN BE OPENED WHILE POWER IS ON, FAILING TO PROVIDE REQUIRED SECURED ACCESS. AS PER ASME A17.1 2.26. REMEDY: SECURE MAIN LINE BOX COVER TO PREVENT ACCESS UNDER POWER. 2. WATER AC #39200048Z | Oct 15, 2026 IN VIOLATION | $0 |
| Jun 25, 2026 | Construction CLASS - 1 FAILURE TO SUBMIT A CERTIFICATE OF CORRECTION OF VIOLATION #39110398J ISSUED ON 04-01-2024 FOR WORK WITHOUT A PERMIT.(NO PERMIT ON DOB RECORD ), COMPLY WITH COMMISSIONER'S ORDER #39193758K | Oct 15, 2026 ADMIT/IN-VIO | $0 |
| Apr 1, 2024 | Construction CLASS - 2 OCCUPANCY CONTRARY TO DOB RECORDS. CO #37239 INDICATES PREMISES AS LEGAL 8 STORY BLDG W/CELLAR. NOTED: PREMISES HAS 9 FLOORS W/CELLAR. 9TH FLOOR OR FLOOR LABELED PH(PENT HOUSE) ARE OCCUPIED BY AT LEAST 1 OFFICE #39110399L | Jun 6, 2024 ADMIT/IN-VIO | $0 |
| Apr 1, 2024 | Construction CLASS - 1 WORK WITHOUT A PERMIT. NOTED ADDITIONAL FLOOR ADDED TO PREMISES. PREMISES ADDED ADDTIONAL FLOOR LABELED PH(PENT HOUSE). PH FLOOR IS ABOVE WHAT IS SUPPOSED TO BE THE 8TH AND TOP FLOOR TO MAKE PREMISES HAVE 9 FLO #39110398J | Oct 28, 2024 ADMIT/IN-VIO | $0 |
| Oct 19, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#803046.AGG1 PRIOR NOV#37021414N UNDER 2 #37022972M | Jun 22, 2023 ADMIT/IN-VIO | $0 |
| Jun 1, 2021 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE8B REPORT OF CRITICAL EXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTENANCES REQUIRED BY28-302.4 FOR CONTROL803046.AGG1:PRIOR NOV37013385N UNDER28-302.4 SUBMIT ACCE #37021414N | Oct 7, 2021 DEFAULT | $0 |
| Oct 15, 2018 | Local Law CLASS - 2 FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL# 803046. REMEDY: SUBMIT REQUIRED TECHNICAL REPORT. #37013385N | May 23, 2019 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 12, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00023 | DOB VIOLATION - ACTIVE |
| Feb 22, 2023 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023 #02005 | DOB VIOLATION - ACTIVE |
| May 29, 2009 | ELEVATOR #306003/9011 | DOB VIOLATION - ACTIVE |
| May 29, 2009 | ELEVATOR #306004/9011 | DOB VIOLATION - ACTIVE |
| Jan 30, 2007 | CONSTRUCTION #MTF02RNS | DOB VIOLATION - ACTIVE |
| Oct 23, 2002 | ELEVATOR #1P6933 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 16, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jun 12, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2023 | Facades FISPNRF CYCLE 9B NO REPORT FILED | Active |
| Jul 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 16, 2008 | B | D26-16.01 ADM CODE REPAIR BY CLOSING SO AS TO BE GAS-TIGHT ALL OPENINGS IN THE DISUSED GAS PIPES AT CELLAR CEILINGS THROUGHOUT. | Jun 20, 2008 |
| May 16, 2008 | B | D26-21.07 ADM CODE PROVIDE A PIECE OF GARDEN HOSE 10 FEET IN LENGTH WITH FEMALE COUPLING AND A 10 QUART PAIL ON PREMISES TO TEST SPRINKLER SYSTEM. | Jun 20, 2008 |
| May 16, 2008 | B | D26-21.07 ADM CODE SEAL IN OPEN POSITION THE O.S.Y. VALVE OF THE SPRINKLER SYSTEM IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT AT 7 STY PUBLIC HALL. | Jun 20, 2008 |
| May 16, 2008 | B | D26-21.07 ADM CODE PROVIDE 3 EXTRA SPRINKLER HEADS AND SUITABLE WRENCH FOR EMERGENCY PURPOSES AT O.S.Y. VALVE OF SPRINKLER IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT AT 7 STY PUBLIC HALL. | Jun 20, 2008 |
| May 16, 2008 | B | § 65 M/D LAW PROVIDE UNDER COMPLETED PERMIT, A PROPER ENCLOSURE FOR THE CENTRAL HEATING PLANT, CELLAR REAR EAST. | Jun 20, 2008 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 16, 2026 | DOB Safety | AEUHAZ: | Closed |
| Sep 16, 2026 | DOB Safety | AEUHAZ: | Closed |
| Sep 16, 2026 | DOB Safety | AEUHAZ: | Closed |
| Sep 16, 2026 | DOB Safety | AEUHAZ: | Open |
| Aug 17, 2026 | ECB | Construction: AT THE TIME OF INSPECTION OBSERVED IN THE LOBBY AREA A SINK THAT WAS INSTALLED WITH OUT A TRAP USING A WASHER MACHINE STYLE HOSE FOR DRAINAGE PC 1002.1 - PLUMBING FIXTURES AND DRAINAGE SYSTEMS SHALL BE PROPERLY | Closed |
| Aug 17, 2026 | ECB | Construction: AT THE TIME OF INSPECTION OBSERVED W HOT WATER HEATERS INSTALLED WITHOUT PRESSURE RELIEF VALVES WHICH IS CONTRARY TO CODE PC 504.6 ESTABLISHES THE REQUIREMENTS FOR DISCHARGE PIPING SERVING TEMPERATURE AND PRESS | Closed |
| Aug 11, 2026 | ECB | Unknown: ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED ON THE GROUND FL KITCHEN ELECTRIC OVEN / FOOD WARMER INSTALLED WITH DISCONNECT SW 3/4 PIPE COMING FROM KITCHEN PANEL. CHECKED BIS / DOB NOW NO PERMIT ON FILE ALL WORK | Open |
| Aug 11, 2026 | ECB | Unknown: FAILURE TO PROTECT CONDUCTOR(S) AGAINST OVERCURRENT. OBSERVED IN BOTH ELEVATOR MACHINE RMS THAT THE OVERCURRENT PROTECTION IS INCORRECT BOTH ARE FUSED AT 100 AMP #6 AWG SHALL BE FUSED AT THE PROPER OVERCURRENT | Open |
| Aug 11, 2026 | ECB | Elevators: CLASS 2: 1. DROP CEILING SECTION LEADING TO TOP EXIT (ESCAPE HATCH) NOT PROPERLY SECURED FROM TOP OF CAR. AS PER ASME A17.1 2.14. REMEDY: SECURE CEILING SECTION. 2. SEPARATION OF CAR DOORS AT BOTTOM WHILE CAR I | Closed |
| Aug 11, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED GARBAGE BINS OBSTRUCTING EGRESS PASSAGEWAY. LOCATED THROUGHOUT BUILDING., REPAIR AND/OR REPLACE | Closed |
| Aug 11, 2026 | ECB | Unknown: FAILURE TO INSTALL GROUNDING ELECTRODE CONDUCTOR. OBSERVED IN THE MAIN ELECTRICAL RM NO INSTALLATION ON ELECTRODE GROUND ROD ALSO THE MAIN HOUSE WATER GROUND CLAMP IS RUSTED AND THE WATER METER IS NOT JUMPED. A | Closed |
| Aug 11, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS THROUGHOUT BUILDING. PREVIOUS VIOLATING # 39156212X., REPAIR AND/REPLACE | Closed |
| Aug 11, 2026 | ECB | Unknown: UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN THE REAR CORRIDOR A HUNG ELECTRIC HEATER WITH A FLEX CORD PASSING THRU THE CEILING. IN | Closed |
| Aug 11, 2026 | ECB | Elevators: CLASS 2: 1. MAIN LINE BOX COVER CAN BE OPENED WHILE POWER IS ON, FAILING TO PROVIDE REQUIRED SECURED ACCESS. AS PER ASME A17.1 2.26. REMEDY: SECURE MAIN LINE BOX COVER TO PREVENT ACCESS UNDER POWER. 2. WATER AC | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 10:56 PM ET. BBL 1009970047.