3 floors · 18,622 sq ft · built 2002 · class W8 · owner of record: Bushwick United Housing Development Fund Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 61 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (4 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-23 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 18, 2025 | Boilers CLASS - 2 NAVIEN HOT WATER HEATING BOILERS INSTALLED W/PERMIT NOT SIGNED OFF PERMIT EXPIRED+SAFETY VALVES DISCHARGE INTO MANIFOLD WITHOUT AIR GAP ON EACH+MANIFOLD SIZED BY ENGINEER+BOILER FLUE TERMINATION NOT BUILT TO NY #39151428M | Nov 2, 2026 PENDING | $1,250 |
| Nov 7, 2018 | Boilers CLASS - 2 36,50A. FOUND NAVIEN BOILER MODEL NCB240 UNREGISTERED AND OPERATING WITH DEFECTS. 50-INCORRECT VENTING MATERIAL. REGISTER BOILER AND COR RECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION. #32096836H | Apr 24, 2019 IN VIOLATION | $0 |
| Nov 7, 2018 | Boilers CLASS - 2 36,50. FOUND NAVIEN BOILER MODEL NCB240 UNREGISTERED AND OPERATING WITH DEFECTS. 50-INCORRECT VENTING MATERIAL. REGISTER BOILER AND COR RECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFIATE OF CORRECTION. #32096837J | Apr 24, 2019 IN VIOLATION | $0 |
| Nov 7, 2018 | Boilers CLASS - 2 36,50 FOUND NAVIEN BOILER MODEL NCB240 UNREGISTERED AND OPERAITNG WITH DEFECTS; 50-INCORRECT VENTING MATERIAL. REGISTER BOILER AND CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION. #32096838L | Apr 24, 2019 IN VIOLATION | $0 |
| Nov 7, 2018 | Boilers CLASS - 2 36.50=FOUND NAVIEN BOILER MODEL-NCB240 UNREGISTERED AND OPERATING WITH DEFECTS(50)INCORRECT VENTING MATERIAL.REGISTER BOILER AND CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION. #32096834Y | Apr 24, 2019 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #22701 | DOB VIOLATION - ACTIVE |
| Nov 8, 2019 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT #10248 | DOB VIOLATION - ACTIVE |
| Apr 6, 2018 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT #12637 | DOB VIOLATION - ACTIVE |
| May 30, 2014 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST #08581 | DOB VIOLATION - ACTIVE |
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #10117 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 8, 2019 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT | Active |
| Apr 6, 2018 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT | Active |
| May 30, 2014 | Elevators ACC1 | Active |
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
None open.