Brooklyn · Block 3266 · Lot 20 · 11221

132 Stanhope Street

3 floors · 18,622 sq ft · built 2002 · class W8 · owner of record: Bushwick United Housing Development Fund Corp

16open violations
$1,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
61dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 61 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 61 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (4 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-23 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (5) · $1,250 owed
IssuedViolationHearingBalance
Jun 18, 2025Boilers CLASS - 2
NAVIEN HOT WATER HEATING BOILERS INSTALLED W/PERMIT NOT SIGNED OFF PERMIT EXPIRED+SAFETY VALVES DISCHARGE INTO MANIFOLD WITHOUT AIR GAP ON EACH+MANIFOLD SIZED BY ENGINEER+BOILER FLUE TERMINATION NOT BUILT TO NY
#39151428M
Nov 2, 2026
PENDING
$1,250
Nov 7, 2018Boilers CLASS - 2
36,50A. FOUND NAVIEN BOILER MODEL NCB240 UNREGISTERED AND OPERATING WITH DEFECTS. 50-INCORRECT VENTING MATERIAL. REGISTER BOILER AND COR RECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION.
#32096836H
Apr 24, 2019
IN VIOLATION
$0
Nov 7, 2018Boilers CLASS - 2
36,50. FOUND NAVIEN BOILER MODEL NCB240 UNREGISTERED AND OPERATING WITH DEFECTS. 50-INCORRECT VENTING MATERIAL. REGISTER BOILER AND COR RECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFIATE OF CORRECTION.
#32096837J
Apr 24, 2019
IN VIOLATION
$0
Nov 7, 2018Boilers CLASS - 2
36,50 FOUND NAVIEN BOILER MODEL NCB240 UNREGISTERED AND OPERAITNG WITH DEFECTS; 50-INCORRECT VENTING MATERIAL. REGISTER BOILER AND CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION.
#32096838L
Apr 24, 2019
IN VIOLATION
$0
Nov 7, 2018Boilers CLASS - 2
36.50=FOUND NAVIEN BOILER MODEL-NCB240 UNREGISTERED AND OPERATING WITH DEFECTS(50)INCORRECT VENTING MATERIAL.REGISTER BOILER AND CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION.
#32096834Y
Apr 24, 2019
IN VIOLATION
$0
DOB (5)
IssuedViolationStatus
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#22701
DOB VIOLATION - ACTIVE
Nov 8, 2019LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
#10248
DOB VIOLATION - ACTIVE
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#12637
DOB VIOLATION - ACTIVE
May 30, 2014(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
#08581
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#10117
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 8, 2019Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Active
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
May 30, 2014Elevators ACC1
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 31, 2026, 1:13 PM ET. BBL 3032660020.