Queens · Block 5104 · Lot 18 · 11355

132-28 Pople Avenue

2 floors · 2 apartments · 2,000 sq ft · built 1945 · class B1 · owner of record: Hy & Sons Enterprises Llc

6open violations
$93,125ECB/OATH penalties owed
0HPD class C (immediately hazardous)
294dto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 294 days
Required only if the owner doesn't live there

Open violations

ECB / OATH (11) · $93,125 owed
IssuedViolationHearingBalance
May 14, 2026Unknown CLASS - 1
OBSERVED NO SHORING AND/OR BRACING OF AN EXPOSED WING WALL/REMNANT PARTY WALL AT EXPOSURE #2 WITH NO OBSERVED MONITORING IN PLACE. ADDITIONALLY, EXPOSURE #2 AND EXPOSURE #4 FAILED TO COMPLY WITH THE REQUIREMENT
#39554192L
Jul 21, 2026
DEFAULT
$12,500
May 14, 2026Cranes and Derricks CLASS - 1
ON REVIEW OF THE GENERAL CONTRACTOR'S (LIC#623036) INSURANCE REQUIREMENTS THROUGH DOB NOW, IT WAS FOUND THEIR WORKERS COMPENSATION POLICY#Q25693086 THROUGH NYSIF HAD EXPIRED ON 4/26/2026. OBSERVING ACTIVE CONST
#39554188Z
Jul 21, 2026
DEFAULT
$12,500
May 14, 2026Construction CLASS - 2
AFTER REVIEWING DOB NOW THE WORK PERMIT Q00909669 IS INVALID EXPIRED 4/26/2026. WORKERS PERFORMING MASONARY WORK AT THE TIME OF INSPECTION
#39554164Y
Jul 21, 2026
DEFAULT
$6,250
May 14, 2026Construction CLASS - 2
FOUR (4) WORKERS WHO WERE OBSERVED ACTIVELY ENGAGED IN MASONRY OPERATIONS, LEFT THE PROJECT AND LOCKED THE DOOR PREVENTING FURTHER INVESTIGATION OF OBSERVED HAZARDOUS CONDITIONS AT EXPOSURE #2 AND #4. CONDITION
#39554189K
Jul 21, 2026
DEFAULT
$10,000
May 14, 2026Site Safety CLASS - 1
CONSTRUCTION SUPERINTENDENT FAILURE TO PERFORM DUTIES, FAILED TO MAINTAIN DOCUMENTS, CORRECT UNSAFE CONDITIONS AND DESIGNATE A COMPETENT PERSON AS IS REFLECTED IN THE VIOLATIONS WRITTEN #039954164Y;159J,175J,1
#39554195R
Feb 4, 2027
$10,000
May 14, 2026Unknown CLASS - 1
UNSAFE CONDITIONS: INADEQUATE HOUSEKEEPING, SMOKING ON SITE, INADEQUATE FIRE EXTINGUISHERS, MISSING HANDRAILS, MISSING GUARDRAILS, UNPROTECTED REINFORCING BAR. BC3301.5
#39554175J
Jul 21, 2026
DEFAULT
$10,000
May 14, 2026Site Safety CLASS - 1
UPON REQUEST TO REVIEW THE FOLLOWING: PROJECT APPROVED PLANS, SITE SAFETY PLAN, CS DAILY LOGBOOK, PRE-CONSTRUCTION SURVEYS, MONITORING PLAN, SHORING AND BRACING PLANS, WORKER ORIENTATIONS, AND WORKER PRE-SHIFT
#39554159J
Jul 21, 2026
DEFAULT
$12,500
Mar 23, 2026Construction CLASS - 2
OBSERVED: FENCE ERECTED ON EXP 4 INSIDE ADJACENT PROPERTY 132-26 POPLEAVE CONTRARY TO DRAWING Q00909669 S1 . STOP ALL WORK ON EXPOSURE 4, 25 FEET DEEP AND 10 FEET INSIDE /PROVIDE FENCE AS PER DRAWINGS PROVIDE
#39552092P
Jun 2, 2026
DEFAULT
$6,250
Apr 4, 2025Construction CLASS - 2
APP.DEMO PLANS NOTES REMOVAL ROOF WOOD JOIST 16INCHES OC AND PROVIDE NEW TEMP WOOD JOIST 3X12 INCH TO SHORE UP PARTY WALLS,IN FIELD OBSERVEDALL ROOF JOIST REMOVED,WORK CONTRARY TO PE NOTES CREATE HAZARD STRUCTU
#39538790L
Aug 6, 2026
DEFAULT
$3,125
Apr 4, 2025Construction CLASS - 2
REVIEWED APP.PLANS REVEALED ALTERATION EXISTING 2 STORY BUILDING TO 4 STORY, TOTAL HEIGHT 54 FEET.WORK COMMENCE REMOVAL EXISTING BUILDING ROOF AND JOIST PRIOR TO INSTALLATION SWS REQUIRED FOR NEW STRUCTURES GRE
#39538791N
Aug 6, 2026
DEFAULT
$5,000
Mar 4, 2025Unknown CLASS - 2
AT TIME OF INSPECTION, I OBSERVED DEMOLITION WORK IS BEING DONE AND NO OVERHEAD PROTECTION WAS PROVIDED FOR ADJACENT PROPERTIES AT EXPOSURE #2 AND EXPOSURE #4 AS PER SECTION BC 3309.1./ STOP ALL WORK ABOVE THE
#39537596N
Aug 19, 2025
DEFAULT
$5,000
DOB (1)
IssuedViolationStatus
May 14, 2026CONSTRUCTION
: A 2-STORY TALL REMANT PARTY WALL AT EXP2 UNBRACED W/ CRACKING PERMITES EXPRD. POSING DANGED TO PUBLIC & ADJ PROP. REMEDY: RETAIN NYSPE TO ASSESS. PVD FINDNGS, PLNS & MONTNG PGM TO CSENG, TAKE MON READNGS/051526. PVD SS STBLZN PLNS TO CSENG/051826. MON SITE & PVD EVAL
#CE40701PW
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 11, 2026, 8:55 AM ET. BBL 4051040018.