Queens · Block 5039 · Lot 62 · 11355

132-09 41 Road

2 floors · 2 apartments · 2,050 sq ft · built 1930 · class B1 · owner of record: 132-09 41st Road Llc

18open violations
$0ECB/OATH penalties owed
5HPD class C (immediately hazardous)
311dto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 311 days
Required only if the owner doesn't live there

Open violations

ECB / OATH (0)

None open.

DOB (1)
IssuedViolationStatus
Jul 25, 2026CONSTRUCTION
STRUCTURE RENDERED NON-COMPLIANT DUE TO DAMAGE CAUSED FROM ADJACENT PROPERTY DUE TO FIRE DAMAGE. OBSERVED DAMAGE TO EXTERIOR AND INTERIOR OF PROPERTY.
#26-01855
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (17) · C 5 · B 11 · A 1
IssuedClassViolationCorrect by
Apr 17, 2025BApt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 17561097 ISSUED 17-DEC-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTMay 22, 2025
Dec 18, 2024CApt 1 · § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES . IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 24, 2024
Dec 18, 2024C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT WEST 2 WINDOW UPPER SASH AT VESTIBULE AT PUBLIC HALL, 1st STORYDec 24, 2024
Dec 18, 2024CApt 1 · § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES . IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 24, 2024
Dec 18, 2024AApt 1 · § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHMar 23, 2025
Dec 18, 2024BApt 1 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJan 22, 2025
Dec 18, 2024BApt 1 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJan 22, 2025
Dec 18, 2024BApt 1 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CEILING PANELS IN THE PRIVATE HALLWAY LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJan 22, 2025
Dec 18, 2024C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT SOUTH 1 WINDOW LOWER SASH AT VESTIBULE AT PUBLIC HALL, 1st STORYDec 24, 2024
Dec 18, 2024BApt 1 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE PRIVATE HALLWAY LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJan 22, 2025
Dec 18, 2024BApt 1 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF BX CABLE RUNNING OUTSIDE OF WEST WALL TO ELECTRICAL OUTLET IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJan 22, 2025
Dec 18, 2024BApt 1 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJan 22, 2025
Dec 18, 2024BApt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJan 22, 2025
Dec 18, 2024B§ 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING AND ALL WALLS AT PUBLIC HALL, 1st STORYJan 22, 2025
Dec 18, 2024B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING AND ALL WALLS AT PUBLIC HALL, 1st STORYJan 22, 2025
Dec 18, 2024C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT SOUTH 2 WINDOW LOWER SASH AT VESTIBULE AT PUBLIC HALL, 1st STORYDec 24, 2024
Dec 18, 2024BApt 1 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT LIGHT FIXTURE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJan 22, 2025

Issued in the last 120 days

DateSourceWhatNow
Jul 25, 2026DOBCONSTRUCTION: STRUCTURE RENDERED NON-COMPLIANT DUE TO DAMAGE CAUSED FROM ADJACENT PROPERTY DUE TO FIRE DAMAGE. OBSERVED DAMAGE TO EXTERIOR AND INTERIOR OF PROPERTY.Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 5:32 AM ET. BBL 4050390062.