Queens · Block 5066 · Lot 151 · 11354

131-02 40 Road

552,699 sq ft · built 2020 · class H2 · owner of record: Hw Hospitality Llc

4open violations
$28,810ECB/OATH penalties owed
0HPD class C (immediately hazardous)
66dto Energy audit and retro-commissioning (2026)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Energy audit and retro-commissioning (2026) Likely applies
Local Law 87 · Calendar year 2026
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5066). Agency page

Dec 31, 2026
in 66 days
Due this year
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 552,699 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1162 days
Next cycle year 2029

Open violations

ECB / OATH (8) · $28,810 owed
IssuedViolationHearingBalance
Oct 22, 2026Construction CLASS - 1
ATOI IN RESPONSE TO AN INCIDENT WHERE A CONCRETE TRUCK OPERATOR WAS INJURED DUE TO UPS TRUCK DRIVING INTO 1 YODOCK INTO A CHAIN LINK FENCE AND CAUSING INJURY. UPON RESEARCH OF APPROVED SITE SAFETY PLAN WORK ARE
#39560931R
Dec 29, 2026
PENDING
$2,500
Jul 30, 2026Construction CLASS - 1
@ACTIVE SITE UP TO 13TH FL WORKING DECK OBSERVE HOUSEKEEPING NOT MAINTAINED THROUGHOUT MULTIPLE FLOORS WITH PILES OF ACCUMULATED COMBUSTIBLE DEBRIS NOT REMOVED FROM SITE TO CODE BC3303.4.2/3303.4.4 EXCEPTIONS C
#39557303Z
Dec 1, 2026
$2,500
Jul 30, 2026Construction CLASS - 1
SITE SAFETY PLAN.@SITE UP TO 13TH FL WORKING DECK,PER PROVIDED APPROVED SITE SAFETY PLAN LIST OF EQUIPMENTS I OBSERVE SPYDER MINI CRANE IN USE NOT ON LIST&INDICATED ON PLAN,CHAINLINK FENCE@INCORRECT LOCATION(PA
#39557302R
Oct 6, 2026
ADMIT/IN-VIO
$0
Jul 30, 2026Construction CLASS - 2
@ACTIVE SITE UP TO 13TH FL WORKING DECK OBSERVE SITES UNSECURED DEBRIS THROUGHOUT UNENCLOSED FLOORS&@EDGES WHERE DEBRIS(STYROFOAM)ALSO DISLODGED ONTO ADJOIN PROPERTIES 131-02 A/B(BC3303.4) ,&LARGE FLOOR HOLE OP
#39557304K
Dec 1, 2026
PENDING
$5,000
May 29, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED COSMETIC DAMAGE TO TWO ADJOINING PROPERTIES AT 131-02B CONSISTENT WITH REBAR SIZE AND INSTALLATION LOCATIONS. GC FAILED TO PROVIDE SAFETY MEASURES TO PROTECT PROPERTYPROVIDE AND M
#39554755X
Jun 28, 2027
DEFAULT
$5,000
Feb 1, 2026Construction CLASS - 2
NEW 19 STORY BUILDING. OBSERVED SITE CLOSED NO ONGOING CONSTRUCTION ACTIVITY UPON EXTERIOR INSPECTION NOTED MISSING SWS PARAPET PROJECT INFORMATION PANEL CONTRARY TO BUILDING CODE
#39549756L
Nov 24, 2026
$1,250
Dec 29, 2025Unknown CLASS - 2
PERFORMED WEATHER ADVISORY SWEEP ON CLOSED JOBSITE FOR A PROPOSED 19-STORY HOTEL. UPON INSPECTION, OBSERVED NO WATCHPERSON PRESENT ON JOBSITE. REFER TO 2014 BUILDING CODE (3303.3), "WHERE AN INDIVIDUAL BUILDING
#39548588R
Oct 6, 2026
DEFAULT
$2,530
Mar 11, 2025Construction CLASS - 1
AT TIME OF INSPECTION, I OBSERVED WORK BEING DONE APPROXIMATELY 16FT ABOVE THE FENCE AT EXPOSURE #1 AND #2 AND NO SIDEWALK SHED WAS PROVIDED. / STOP ALL WORK ABOVE THE FENCE AT EXPOSURE #1 AND #2.
#39537857M
Oct 27, 2026
$10,030
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Sep 2, 2026AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 22, 2026ECBConstruction: ATOI IN RESPONSE TO AN INCIDENT WHERE A CONCRETE TRUCK OPERATOR WAS INJURED DUE TO UPS TRUCK DRIVING INTO 1 YODOCK INTO A CHAIN LINK FENCE AND CAUSING INJURY. UPON RESEARCH OF APPROVED SITE SAFETY PLAN WORK AREOpen
Sep 2, 2026DOB SafetyAEUHAZ: Open
Sep 2, 2026DOB SafetyAEUHAZ: Closed
Aug 3, 2026ECBUnknown: @SITE UP IN STRUCTURE PHASE OBSERVE WORKER/CONTRACTOR SHEDS,CONTRACTOR OFFICES,&SIMILAR STRUCTURES ON 1ST FL(2 SHEDS WITHIN 30FT DISTANCE+NO FIRE SUPPRESSION),&ON 2ND FLOOR(3SHEDS)IN USE ALL EXCEEDED 120SQ FT&IClosed
Jul 30, 2026ECBConstruction: @ACTIVE SITE UP TO 13TH FL WORKING DECK OBSERVE HOUSEKEEPING NOT MAINTAINED THROUGHOUT MULTIPLE FLOORS WITH PILES OF ACCUMULATED COMBUSTIBLE DEBRIS NOT REMOVED FROM SITE TO CODE BC3303.4.2/3303.4.4 EXCEPTIONS CClosed
Jul 30, 2026ECBConstruction: SITE SAFETY PLAN.@SITE UP TO 13TH FL WORKING DECK,PER PROVIDED APPROVED SITE SAFETY PLAN LIST OF EQUIPMENTS I OBSERVE SPYDER MINI CRANE IN USE NOT ON LIST&INDICATED ON PLAN,CHAINLINK FENCE@INCORRECT LOCATION(PAOpen
Jul 30, 2026ECBConstruction: @ACTIVE SITE UP TO 13TH FL WORKING DECK OBSERVE SITES UNSECURED DEBRIS THROUGHOUT UNENCLOSED FLOORS&@EDGES WHERE DEBRIS(STYROFOAM)ALSO DISLODGED ONTO ADJOIN PROPERTIES 131-02 A/B(BC3303.4) ,&LARGE FLOOR HOLE OPOpen
Jul 30, 2026ECBUnknown: @ACTIVE SITE UP TO 13TH FLOOR WORKING DECK OBSERVE TEMPORARY STANDPIPE IN PLACE FOR FDNY OPERATIONS UP TO 10TH FLOOR AND I CONFIRMED PER DEPARTMENTS RECORDS, THERE ARE NO STANDPIPE PERMIT ISSUED(JOB#Q01380117 AClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 6:20 AM ET. BBL 4050660151.

Look up another building