Brooklyn · Block 357 · Lot 4 · 11231

13 Woodhull Street

1 floors · 887 sq ft · built 1931 · class K1 · owner of record: Woodhull Properties Nyc Corp.

25open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)

Open violations

ECB / OATH (16)
IssuedViolationHearingBalance
Jan 16, 2008Construction Hazardous
FAILURE TO MAINTAIN BLDG NOTED ONE STY BLDG THE ROOF HAS COLLAPDED EXPOSING THE BLDG TO THE ENVIRONMENT ELEMENTS INSIDE THE BLDG IS FULL OF COLLAPSED ROOF MATERIAL AND DEBRIS THIS CONDITION IS NOT SAFE
#34622998K
Mar 17, 2008
WRITTEN OFF
$0
Aug 25, 2007Construction Hazardous
FAILURE TO MAINTAIN BLDG WALL(EXTERIOR)NOTED:THE ROOF HAS COLLAPSED THUS EXPOSING THE BLDG TO THE ENVIRONMENT ELEMENTS.SECTION OF BRICK & MORTAR ARE MISSING AT THE WESTERN SECTION OF THE BLDG.REMEDY:MAKE ALL NE
#34592763L
Apr 28, 2008
DEFAULT
$0
Aug 1, 2007Construction Hazardous
FAILURE TO MAINTAIN BLDG: NOTE: 1. STORY BRICK BLDG: NOTE 1 STORY BRICK BLDG IS IN A DELAPIDATED CONDITION THROUGHOUT. AT LEFT SIDE OF BLDG PARTIAL COLLAPSE OF BRICK WALL AND LOOSE MASONRY UNITS AT ROOF LEVEL
#34573442R
Oct 15, 2007
DEFAULT
$0
Jul 29, 2007Construction Hazardous
FAILURE TO MAINTAIN EXTERIOR BLDG WALL NOTED AT THE NORTH WEST CORNER AT FRONT SECTION OF BRICK & PARAPET COPING STORE MISSING & NORTH ELEVATION BRICK MISSING CRACKED & IN DISREPAIR. REMEDY: MAKE ALL NECESSARY
#34553761X
Sep 24, 2007
WRITTEN OFF
$0
Mar 1, 2007Construction Hazardous
FAILURE TO MAINTAIN BLDG IN THAT ROOF HAS COLLAPSED,EXPOSING BLDG TO ELEMENTS SECTION OF BRICK & MORTAR MISSING @ WEST SIDE ALL.REMEDY:MAKE ALL NECESSARY REPAIRS FORTHWITH OR APPLY FOR DEMO/PERMIT & REMOVE STRU
#34545262L
Apr 23, 2007
DEFAULT
$0
Oct 25, 2006Construction Hazardous
FAILURE TO MAINTAIN EXTERIOR BLDG WALL.HAZARDOUS DEFECTS ARE:ROOF COLLAPSED EXPOSING BLDG TO THE NATURAL ELEMENT.BRICK WORK CRACKED,SECTION MISSING @ ROOF PARAPET AREA.MARTOR JOINTS ERODED MISSING & BRICK WALL
#34542115H
Sep 17, 2007
DEFAULT
$0
Mar 24, 2005Construction Hazardous
FAILURE TO MAINTAIN EXTERIOR BUILDING WALL-HAZARDOUS.NOTED:BRICKS BROKEN,LOOSE,AND/OR MISSING ON THE NORTH SIDE OF BUILDING AT THE ROOF LINE,NORTH/WEST SECTION APPRX 2'FT BY 1'FT COLLAPSED INTO BUILDING.REMEDY:
#34463718L
May 9, 2005
DEFAULT
$0
Dec 9, 2002Construction Hazardous
FAILURE TO MAINTAIN EXTERIOR BUILDING WALL HAZARDOUS DEFECTS ARE AT WEST SIDE OF BUILDING AT VARIOUS LOCATIONS ARE LARGE HOLES IN BRICK WALL APPROX 3'X6', 2'X2' AND 1'X4' ALSO ARE LOOSE BULGING AND MISSING BRIC
#34371532P
Jan 27, 2003
WRITTEN OFF
$0
Jul 2, 2002Construction Hazardous
FAILURE TO MAINTAIN EXTERIOR BLDG WALL: HAZARDOUS DEFECT ARE: AT SIDE OF BLDG WEST ARE LOOSE, UNKEYED AND MISSING BRICKS EXPOSING ROOF JOISTS, ALSO LARGE HOLE IN WALL APPROX 3' X 4' COVERED WITH A BLUE TARPOTIN
#34322783Z
Apr 7, 2003
WRITTEN OFF
$0
Jun 28, 2002Construction Hazardous
FAILURE TO MAINTIAN EXTERIOR BUILDING WALL HAZARDOUS DEFECT IS APPROX3' X 4' IN WALL ALSO LOOSE MISSING DEFECTIVE BRICK WORK AT REAR WEST WALL. REMEDY : MAINTIAN EXTERIOR BUILDING WALL
#34322720L
Aug 12, 2002
WRITTEN OFF
$0
Jun 19, 2002Construction Hazardous
FAILURE TO MAINTAIN EXTERIOR BUILDING WALL HAZARDOUS DEFECT APPROX 3'X4' HOLE IN WALLALSO LOOSE MISSING AND DEFECTIVE BRICKS AT REAR WEST WALL REMEDY MAINTAIN EXTERIOR BUILDING WALL
#34322598R
Aug 5, 2002
WRITTEN OFF
$0
Mar 8, 2002Construction Hazardous
FAILURE TO MAINTAIN EXTERIOR BUILDING WALL HAZARDOUS DEFECTS ARE AT SIDE OF BUILDING WEST BRICKS ARE UNKEYED AND LOOSE 2 LARGE HOLES IN WALL APPROX 2'X2',2'X6'AND AT ROOF ARE MISSING BRICKS APPROX 2'X8' WITH
#34317741Y
Apr 22, 2002
WRITTEN OFF
$0
Feb 19, 2002Construction Hazardous
FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. HAZARDOUS DETECT IS APPROX 3'X4' HOLE IN WALL. ALSO LOOSE MISSING AND DETECTIVE BRICK WORK AT REAR WEST WALL. REMEDY: MAKE ALL REPAIRS TO EXTERIOR BUILDING WALL SUIT
#34317453J
Jun 10, 2002
WRITTEN OFF
$0
Feb 11, 2002Construction Hazardous
FAILURE TO MAINTAIN EXTERIOR BUILDING WALL: DEFECT IS: CRACKED BROKEN & OUT OF PLUMB MISSING CEMENT STYCCO AT EXPOSED WEST WALL MISSING ROOF COPING MISSING LEEDERS & GUTTERS AS WELL. REMEDY: MAINTAIN EXTERIOR B
#34317381J
Apr 1, 2002
WRITTEN OFF
$0
Mar 9, 2001Construction Non-Hazardous
WORK WITHOUT PERMIT.WORK NOTED AT WEST WALL 8'MASONARY CIDER BLOCK AS WELL AS BRICK ARE BEING INSTALLED ONTO BEARING WALL.NOTE:NO BRICK OR BLOCK TIES BEING USED NO REINFORMIGN WIRE BEING USED.REM;STOP ALL WORK
#34280947N
Apr 23, 2001
WRITTEN OFF
$0
Mar 7, 2001Construction Hazardous
FAILURE TO MAINTAIN EXTERIOR BLDG WALL.NOTE:AT 1FL LEVEL ON WEST SIDE OF BLDG A HOLE APPROX.3'X8'HIGH EXIST IN THE BEARING WALL AND AT 1FL REAR THEIR EXIST AN OPENING IN WALL APPROX 1'X6' MAKING THE WALL IN POS
#34280945J
Apr 23, 2001
WRITTEN OFF
$0
DOB (7)
IssuedViolationStatus
May 2, 2017CONSTRUCTION

#0601RF
DOB VIOLATION - ACTIVE
Oct 23, 2007UNSAFE BUILDINGS

#3805/07
DOB VIOLATION - ACTIVE
Aug 7, 2007IMMEDIATE EMERGENCY

#167/07
DOB VIOLATION - ACTIVE
Mar 9, 2001CONSTRUCTION
WORK WITHOUT A PERMIT. WORK NOTED: AT WEST WALL 8" MASONRY CINDER BLOCK AS WELL AS BRICK ARE INSTALLED ONTO BEARING WALL. NOTED: NO BRICK OR BLOCK TIES BEING USED. NO REINFORCING WIRE IS BEING USED REMEDY:"STOP ALL WORK". EXCEPT TO SHORE ENTIRE HALL, OBTAIN ALL NECESSARY PERMITS TO REPAIR ENTIRE BLD
#06EM01
VIOLATION WORK WITHOUT PERMIT - ACTIVE
Mar 7, 2001CONSTRUCTION
HAZARDOUS
#06EM01
DOB VIOLATION - ACTIVE
Feb 21, 2001IMMEDIATE EMERGENCY

#037/01
DOB VIOLATION - ACTIVE
Feb 8, 2001CONSTRUCTION
HAZARDOUS
#02S01
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
HPD (1) · C 0 · B 1 · A 0
IssuedClassViolationCorrect by
Sep 8, 2009BApt BUILD · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ERODED MORTAR JOINTS AND BRICKS AT WEST PARAPT WALL AT ROOF AND WALLOct 13, 2009

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 11:18 PM ET. BBL 3003570004.