6 floors · 55,224 sq ft · built 1930 · class O5 · owner of record: New York University
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 56 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 55,224 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 177 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 177 days | Annual filing |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 548). Agency page | Dec 31, 2028 in 787 days | Next due 2028 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1152 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 15, 2013 | Construction CLASS - 2 WORK DOES NOT CONFORM AO APPROVED CONSTRUCTION DOCUMENTS. NOTED: INSTALLATION OF SUPPORTED SAFFOLD AT REAR ELEVATION, IS NOT SHOWING HOIST INSTALLATION AND SHAF WAY WHERE WORKER FELL; RESULTING IN A FATALITY RE #35031482L | Jan 2, 2014 WRITTEN OFF | $0 |
| Nov 15, 2013 | Unknown CLASS - 1 3314.8 GUARD RAIL SYSTEMS AND TOEBOARDS NOTED:INADEQUATE GUARD RAIL SYSTEM AND TOEBOARDS ON SUSPENDED ROPE SCAFFOLD, MISSING APPROX:3FT OF GUARD RAILS AND TOE BOARDS. REMEDY: COMPLY W/CODE #35031484P | May 15, 2014 IN VIOLATION | $0 |
| Nov 15, 2013 | Construction CLASS - 1 3314.8 GUARD RAIL SYSTEM AND TOEBOARDS NOTED:AT ALL WORK (LEVERS), GUARD RAIL SYSTEM & TOEBOARDS ARE MISSING THROUGHOUT INSTALLATION, ON WORKING PLATFORMS REMEDY: COMPLY W/ CODE #35031478Z | May 15, 2014 IN VIOLATION | $0 |
| Nov 15, 2013 | Construction CLASS - 1 3314.4.1 UPON COMPLETION OF THE INSTALLATION OF THE SCAFFOLD, AN INSPECTION REPORT WORKING THAT THE SCAFFOLD HAS BEEN INSTALLED IN ACCORDANCE WITH THE DESIGN DRAWINGS. NOTED: AT TIME OF INSPECTION, NO SIGN OFF #35031575K | May 15, 2014 WRITTEN OFF | $0 |
| Nov 15, 2013 | Construction CLASS - 1 3314.6 SAFE POINTS OF ANCHORAGE: NOTED: AT TIME OF INSPECTION OBSERVED TIES FROM SUPPORTED SCAFFOLD HAVE BEEN COMPROMISED BY BEING DISCONNECTED, DUE TO BRICK REPLACEMENT REMEDY:COMPLY W/ CODE #35031476P | May 15, 2014 IN VIOLATION | $0 |
| Nov 15, 2013 | Construction CLASS - 1 3314.5 PLATFORM CONSTRUCTION. NOTED: ALL WORK (LEVERS) ON PIPE SCAFFOLD, NOT FULLY PLANKED AND EXPOSED OPEN AREAS THROUGHOUT REMEDY:COMPLY W/ CODE #35031477R | May 15, 2014 IN VIOLATION | $0 |
| Nov 15, 2013 | Construction CLASS - 1 USE OF SUPPORTED SCAFFOLD W/O A SCAFFOLD USER CERTIFICATE NOTED: TWO WORKERS ON SUPPORTED SCAFFOLD W/O SCAFFOLD USER CERTIFICATE 1. JOB STENART , MR DAIREN W TORRES EXPIRED SCAFFOLD CARD 2.DECEASE: MR JAIME SIL #35031481J | May 15, 2014 WRITTEN OFF | $0 |
| Nov 15, 2013 | Construction CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATION NOTED:A FATALITY RESULTED IN A WORKER FALLING APPROX 70 FT OFF SUPPORTED SCAFFOLD AT REAR ELEVATION AND LANDED INSIDE OF HOIST LAND #35031475N | May 15, 2014 IN VIOLATION | $0 |
| Nov 15, 2013 | Cranes and Derricks CLASS - 1 NO RECORD OF DAILY INSPECTION OF SUSPENDED SCAFFOLD PERFORMED BY AUTHORIZED PERSON ON SITE NOTED:NO DAILY RECORD OF INSPECTION FOR SUSPENDED SCAFFOLD AT REAR ELEVATION REMEDY:MAINTAIN DAILY RECORDS. #35031485R | May 15, 2014 IN VIOLATION | $0 |
| Nov 15, 2013 | Construction CLASS - 1 3314.13.1 BRACING: NOTED: FRAMES & PANELS SHALL BE BRACE BY CROSS BRACES, CROSS BRACES MISSING AT WORK LEVER, HOIST AREA REMEDY: COMPLY W/ CODES #35031479K | May 15, 2014 IN VIOLATION | $0 |
| Nov 15, 2013 | Construction CLASS - 1 3314.4.3 INSPECTIONS: ALL SCAFFOLDS SHALL BE INSPECTED DAILY BEFORE EACH USE. NOTED:AT TIME OF INSPECTION NO DAILY LOG ON SITE FOR SCAFFOLD INSPECTION PERFORM BY A COMPETENT PERSON REMEDY:COMPLY W/ CODE #35031483N | May 15, 2014 WRITTEN OFF | $0 |
| Nov 15, 2013 | Cranes and Derricks CLASS - 1 INADEQUATE SAFETY MEASURES: OPERATION OF HOISTING EQUIPMENT IN UNSAFE MANNER NOTED:BETA MA HOIST INSTALLED ON SUPPORTED SCAFFOLD, HAS DEFECTED CABLE W/ FLAT SPOTS. BIRD CAGING AND KINKS, THIS HOIST WAS IN USE A #35031480H | May 15, 2014 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00027 | DOB VIOLATION - ACTIVE |
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00025 | DOB VIOLATION - ACTIVE |
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00018 | DOB VIOLATION - ACTIVE |
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00022 | DOB VIOLATION - ACTIVE |
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00020 | DOB VIOLATION - ACTIVE |
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00019 | DOB VIOLATION - ACTIVE |
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00023 | DOB VIOLATION - ACTIVE |
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00017 | DOB VIOLATION - ACTIVE |
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00021 | DOB VIOLATION - ACTIVE |
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00024 | DOB VIOLATION - ACTIVE |
| Feb 12, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00026 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 12, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 5, 2026, 10:10 PM ET. BBL 1005480009.