12 floors · 23 apartments · 27,323 sq ft · built 2009 · class D1 · owner of record: Persam White Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 27,323 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $217,680 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2028 in 464 days | No Cycle 10 report on record yet |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 778 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 2, 2026 | Elevators CLASS - 1 (1) IN-CAR PHONE INOPERATIVE. (2) CLEANING OF ELEVATOR PIT. (3) REPLACE COUNTER WEIGHT ROLLER GUIDES. (4) REPLACE ROLLER GUIDE ON ELEVATOR. (5) CLEANING TOP OF CAR. (6) CLEANING OFF OIL LEAKAGE FROM TOP OF CAR #39210271K | Jan 13, 2027 PENDING | $3,125 |
| Jul 29, 2026 | Elevators CLASS - 2 5.1.21.1 EMERGENCY SIGNAL CAR PHONE INOPERATIVE, CLEAN OIL FROM MAIN BRAKE. #39198156X | Oct 14, 2026 DEFAULT | $655 |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2024 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2401122 | DOB VIOLATION - ACTIVE |
| Apr 18, 2023 | CONSTRUCTION EMERGENCY WORK ORDER DUE #FA30301XN | DOB VIOLATION - ACTIVE |
| Dec 1, 2022 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2201133 | DOB VIOLATION - ACTIVE |
| Feb 9, 2022 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO FAILURE TO MAINTAIN EXTERIOR BLDG FACADE AND APPURTENANCES. THE BALCONIES ON EAST ELEVATION EXPOSURE #2 AND WEST ELEVATION EXPOSURE #4 HAVE SPALLING DETERIORATIONS AND BROKEN CONCRETE ON BALCONY SLABS. REMEDY: PROVIDE SAFETY MEASURES AND IMMED REPAIR UNSAFE BALCONIES AS P #LLFJF02 | DOB VIOLATION - ACTIVE |
| Feb 9, 2022 | CONSTRUCTION FAILURE TO MAINTAIN EXTERIOR BLDG FACADE AND APPURTENANCES. AT TIME OF INSPECTION WEST ELEVATION EXP 2 AND WEST ELEVATION EXP 4 BALCONIES WITH SPALLING AND DETERIORATING CONCRETE AND EXPOSIED STEEL RAILING POST DUE TO BROKEN CONCRETE ON BALCONIES SLABS. REMEDY: MAINTAIN BLDG FACADE AND APPURTENANCES #LLFJF03 | DOB VIOLATION - ACTIVE |
| Oct 13, 2021 | ELEVATOR #9027/709086 | DOB VIOLATION - ACTIVE |
| Feb 2, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00570 | DOB VIOLATION - ACTIVE |
| Jun 10, 2015 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTION/TEST #03362 | DOB VIOLATION - ACTIVE |
| Oct 31, 2014 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST #03904 | DOB VIOLATION - ACTIVE |
| Mar 31, 2014 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST #06775 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Sep 3, 2026 | GHG Emissions - LL97 FTF-EN-LL97321 FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B). | Active |
| Sep 3, 2026 | GHG Emissions - LL97 FTF-EN-LL97321 FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B). | Active |
| Sep 3, 2026 | GHG Emissions - LL97 FTF-EN-LL97321 FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B). | Active |
| Sep 3, 2026 | GHG Emissions - LL97 FTF-EN-LL97321 FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B). | Active |
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 3) | Active |
| Dec 18, 2025 | GHG Emissions - LL97 FTF-EN-LL97321 | Active |
| Dec 18, 2025 | GHG Emissions - LL97 FTF-EN-LL97321 | Active |
| Dec 18, 2025 | GHG Emissions - LL97 FTF-EN-LL97321 | Active |
| Dec 18, 2025 | GHG Emissions - LL97 FTF-EN-LL97321 | Active |
| Dec 1, 2024 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Dec 1, 2022 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Feb 2, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jun 10, 2015 | Elevators EVCAT1 | Active |
| Oct 31, 2014 | Elevators EVCAT1 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Feb 17, 2023 | B | Apt APT12A · § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE 2 CUBIC YARDS OF HOUSEHOLD ARTICLES AT BOILER ROOM AT SOUTH IN THE PRIVATE HALLWAY LOCATED AT APT APT12A, 12th STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 24, 2023 |
| Feb 17, 2023 | B | Apt APT12A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT APT12A, 12th STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 24, 2023 |
| Feb 17, 2023 | B | Apt APT12A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT APT12A, 12th STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 24, 2023 |
| Feb 17, 2023 | C | Apt APT12A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 9, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT APT12A, 12th STORY, 1st | Mar 15, 2023 |
| Jan 26, 2018 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | May 1, 2018 |
| Jan 26, 2018 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | May 1, 2018 |
| Jan 26, 2018 | A | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY | May 1, 2018 |
| Jan 26, 2018 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING ON WALL AT PUBLIC HALL, 1st STORY | Feb 3, 2018 |
| Mar 27, 2012 | A | Apt 1A · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st BEDROOM FROM EAST LOCATED AT APT 1A, 1st STORY | Jun 30, 2012 |
| Date | Source | What | Now |
|---|---|---|---|
| Nov 2, 2026 | ECB | Elevators: (1) IN-CAR PHONE INOPERATIVE. (2) CLEANING OF ELEVATOR PIT. (3) REPLACE COUNTER WEIGHT ROLLER GUIDES. (4) REPLACE ROLLER GUIDE ON ELEVATOR. (5) CLEANING TOP OF CAR. (6) CLEANING OFF OIL LEAKAGE FROM TOP OF CAR | Open |
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |
| Sep 3, 2026 | DOB Safety | GHG Emissions - LL97: FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B). | Open |
| Sep 3, 2026 | DOB Safety | GHG Emissions - LL97: FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B). | Open |
| Sep 3, 2026 | DOB Safety | GHG Emissions - LL97: FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B). | Open |
| Sep 3, 2026 | DOB Safety | GHG Emissions - LL97: FAILURE TO FILE A COMPLIANCE REPORT AS REQUIRED BY AD CODE SEC. 28-321.3 IN ACCORDANCE WITH 1 RCNY § 103-17(B). | Open |
| Jul 29, 2026 | ECB | Elevators: 5.1.21.1 EMERGENCY SIGNAL CAR PHONE INOPERATIVE, CLEAN OIL FROM MAIN BRAKE. | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 4:42 PM ET. BBL 3017780031.