5 floors · 20 apartments · 15,846 sq ft · built 1920 · class C1 · owner of record: Nyc Housing Authority
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 50 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 50 days | Annual |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-27 (Accepted). Agency page | Dec 31, 2026 in 50 days | 1 of 3 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 66 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 294 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 781 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 10, 2024 | Boilers CLASS - 2 FOUND A WEILMCLAIN 488R BOILER WITH SPILL SWITCH MISSING/REAR SIGHT GLASS OPEN/AIR SEPARATOR ON HEADER SIDE LEAKING/CORRECT ALL VIOLATING CONDITIONS /SUBMIT CERTIFICATE OF CORRECTIONS #39114048H | Jun 13, 2024 POP/IN-VIO | $0 |
| Nov 1, 2023 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. SWS ERECTED AT EXP 1 MISSING 5 FEET MINIMUM EXTENSION ON BOTH LEFT AND RIGHT SIDES AS REQUIRED PER CODE (3307.6.3), ALSO 1 ROTTEN MUDSILL AND 1 MUDSILL C #39098472J | Jan 11, 2024 DEFAULT | $10,000 |
| Issued | Violation | Status |
|---|---|---|
| May 13, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. SPALLED WINDOW SILL EXP1. EXPS 2,3&4 CRACKS ON STUCCO WERE OBSERVED. AT EXPOSURE 3 FACADE APPEARED TO BULGING. AT ROOF CRACKS AND BROKEN COPING STONES WERE OBSERVED. REMEDY: REPAIR AND/OR REPLACE #SR11003MA | DOB VIOLATION - ACTIVE |
| Jul 19, 2013 | LL11/98-LOCAL LAW 11/98 - FACADE CYCLE 7 UNSAFE REPORT FILED #HAZ74324 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jul 19, 2013 | Facades LL11/98 CYCLE 7 UNSAFE REPORT FILED | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 29, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCHSET AT BUILDING ENTRANCE , 1st STORY | Aug 3, 2026 |
| Jun 29, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCHSET AT BUILDING ENTRANCE , 1st STORY | Jul 13, 2026 |
| Nov 17, 2025 | A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Feb 20, 2026 |
| Nov 17, 2025 | A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Feb 20, 2026 |
| Mar 10, 2025 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Mar 16, 2025 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 11, 2026, 8:23 AM ET. BBL 1020110022.