5 floors · 19 apartments · 9,639 sq ft · built 1900 · class C7 · owner of record: Ng, John W
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 67 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-06 (Accepted). Agency page | Dec 31, 2026 in 67 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 83 days | Annual |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1163 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 27, 2026 | Unknown CLASS - 2 I OBSERVED UNSAFE UNSUITABLE ELECTRICAL CONDITIONS, LIVE WIRES HANGING AND EXPOSED UNDER AWNING "WAH CHEUNG TRADING INC.), COMPLY WITH EC; FIX ALL CONDITIONS AS PER NEC AND NYC AMENDMENTS #39178615H | May 7, 2026 DEFAULT | $4,000 |
| Feb 27, 2026 | Unknown CLASS - 2 I OBSERVED USE OF EXTENSION CORD AS PERMANENT WIRING TO POWER LIGHT FIXTURES UNDER AWNING.; NEC 400.12, COMPLY WITH EC CODE; FIX ALL CONDITIONS AS PER NEC AND NYC AMENDMENTS #39178614X | May 7, 2026 DEFAULT | $4,000 |
| Feb 27, 2026 | Unknown CLASS - 2 I OBSERVED UNSAFE UNSUITABLE ELECTRICAL CONDITIONS, WIRES DAMAGE INSIDE RACEWAY DO TO SHORT FOR NOT PROPER RACEWAY CONNECTION., COMPLY WITH EC; FIX ALL CONDITIONS AS PER NEC AND NYC AMENDMENTS #39178627P | May 7, 2026 DEFAULT | $4,000 |
| Issued | Violation | Status |
|---|---|---|
| Feb 27, 2026 | CONSTRUCTION I OBSERVED UNSAFE UNSUITABLE ELECTRICAL CONDITIONS DUE TO FIRE, WIRES DAMAGE INSIDE RACEWAY DO TO SHORT FOR NOT PROPER RACEWAY CONNECTION. #26-00635 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #27752 | DOB VIOLATION - ACTIVE |
| Apr 6, 2018 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT #00796 | DOB VIOLATION - ACTIVE |
| Dec 13, 2011 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT #04394 | DOB VIOLATION - ACTIVE |
| Dec 31, 2009 | LOW PRESSURE BOILER #05181 | DOB VIOLATION - ACTIVE |
| Mar 21, 2001 | ZONING #B202DM | DOB VIOLATION - ACTIVE |
| Apr 14, 2000 | CONSTRUCTION #ZSTF07MAD | DOB VIOLATION - ACTIVE |
| Apr 14, 2000 | ZONING #B222GJ | DOB VIOLATION - ACTIVE |
| Apr 14, 2000 | ZONING #B211GJ | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 2) | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 6, 2018 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Dec 31, 2009 | Boiler LBLVIO | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Feb 27, 2026 | I | § 27-2089 ADM CODE THE PREMISES HAVE BEEN VACATED BY AN ORDER OF THIS DEPARTMENT AND CANNOT BE REOCCUPIED EXCEPT FOR CARETAKER, UNTIL (1) AN APPLICATION AND PLAN FOR THE WORK REQUIRED BY THIS ARTICLE HAVE BEEN FILED WITH AND APPROVED BY THE DEPARTMENT OF BUILDINGS, WHERE REQUIRED, (2) SUCH WORK HAS | — |
| Feb 27, 2026 | I | § 27-2089 ADM CODE THE PREMISES HAVE BEEN VACATED BY AN ORDER OF THIS DEPARTMENT AND CANNOT BE REOCCUPIED EXCEPT FOR CARETAKER, UNTIL (1) AN APPLICATION AND PLAN FOR THE WORK REQUIRED BY THIS ARTICLE HAVE BEEN FILED WITH AND APPROVED BY THE DEPARTMENT OF BUILDINGS, WHERE REQUIRED, (2) SUCH WORK HAS | — |
| May 7, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 10, 2026 |
| Feb 25, 2026 | C | Apt 6 · § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 6, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION '' | Feb 21, 2026 |
| Feb 25, 2026 | C | Apt 1 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''FRONT'' | Feb 21, 2026 |
| Feb 25, 2026 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RATED MATERIAL AT NORTH WALL AT PUBLIC HALL, 1st STORY, SECTION ''FRONT'' | Mar 3, 2026 |
| Feb 25, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL AT PUBLIC HALL, 1st STORY, SECTION ''FRONT'' | May 31, 2026 |
| Feb 25, 2026 | C | Apt 5 · § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION '' | Feb 21, 2026 |
| Feb 25, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL AT PUBLIC HALL, 3rd STORY, SECTION ''FRONT'' | May 31, 2026 |
| Feb 25, 2026 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RATED MATERIAL AT NORTH WALL AT PUBLIC HALL, 3rd STORY, SECTION ''FRONT'' | Mar 3, 2026 |
| Feb 25, 2026 | C | Apt 5 · § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION '' | Feb 21, 2026 |
| Feb 25, 2026 | C | Apt 7 · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING, WALL OUTLETS AND LIGHT SWITCHES IN THE ENTIRE APARTMENT LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''REAR'' | Mar 3, 2026 |
| Feb 25, 2026 | C | Apt 4 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''FRONT'' | Feb 21, 2026 |
| Feb 25, 2026 | C | Apt 6 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''FRONT'' | Feb 21, 2026 |
| Feb 25, 2026 | C | Apt 5 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''REAR'' | Feb 21, 2026 |
| Feb 25, 2026 | C | Apt 7 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''REAR'' | Feb 21, 2026 |
| Feb 25, 2026 | C | Apt 6 · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING, WALL OUTLETS AND LIGHT SWITCHES IN THE ENTIRE APARTMENT LOCATED AT APT 6, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''FRONT'' | Mar 3, 2026 |
| Feb 25, 2026 | C | Apt 5 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''FRONT'' | Feb 21, 2026 |
| Feb 25, 2026 | C | Apt 1 · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING, WALL OUTLETS AND LIGHT SWITCHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''FRONT'' | Mar 3, 2026 |
| Feb 25, 2026 | C | Apt 1 · § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION '' | Feb 21, 2026 |
| Feb 25, 2026 | C | Apt 4 · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING, WALL OUTLETS AND LIGHT SWITCHES IN THE ENTIRE APARTMENT LOCATED AT APT 4, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''FRONT'' | Mar 3, 2026 |
| Feb 25, 2026 | C | Apt 4 · § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 4, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION '' | Feb 21, 2026 |
| Feb 25, 2026 | C | Apt 5 · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING, WALL OUTLETS AND LIGHT SWITCHES IN THE ENTIRE APARTMENT LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''FRONT'' | Mar 3, 2026 |
| Feb 25, 2026 | C | Apt 5 · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING, WALL OUTLETS AND AT LIGHT SWITCHES IN THE ENTIRE APARTMENT LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''REAR'' | Mar 3, 2026 |
| Feb 25, 2026 | C | Apt 7 · § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 7, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION '' | Feb 21, 2026 |
| Feb 23, 2026 | C | § 27-2005 HMC: IMMEDIATELY PROVIDE A FIRE GUARD AS DIRECTED BY THE NYC DEPT. OF HOUSING PRESERVATION & DEVELOPMENT (HPD) AND/OR THE NYC DEPT. OF BUILDINGS (DOB) TO PROTECT AGAINST FIRE HAZARDS OBSERVED BY HPD AND/OR DOB. FIRE HAZARDS OBSERVED BY HPD HAVE RESULTED IN THE FOLLOWING ADDITIONAL HPD VIOL | Feb 19, 2026 |
| Feb 20, 2026 | C | Apt 5 · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 26, 2026 |
| Feb 20, 2026 | C | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES FROM THE1ST FLOOR TO THE 5TH FLOOR AT PUBLIC HALL | Feb 26, 2026 |
| Feb 20, 2026 | C | Apt 5 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 20, 2026 |
| Feb 20, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Feb 26, 2026 |
| Feb 20, 2026 | C | Apt 5 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 20, 2026 |
| Jun 12, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 15, 2025 |
| Aug 18, 2008 | B | D26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSE HOLD ITEMS 4 STY PUBLIC HALL. | Sep 22, 2008 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 3:38 AM ET. BBL 1002370026.