3 floors · 2 apartments · 2,139 sq ft · built 1931 · class S2 · owner of record: Barrage Promoters Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 66 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 310 days | Required only if the owner doesn't live there |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 2, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. NO CERTIFICATE OF CORRECTION ON FILE FOR VIO#39142210P AS OF 1/2/2026, FILE A CERTIFICATE OF #39172246Y | Mar 11, 2026 IN VIOLATION | $1,250 |
| Dec 30, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. NO CERTIFICATE OF CORRECTION FOR VIO#39155512N AS OF 12/30/2025., FILE A CERTIFICATE OF CORR #39171890K | Sep 8, 2026 IN VIOLATION | $1,250 |
| Jul 30, 2025 | Construction CLASS - 1 ATOI OF A 3-STORY BUILDING IT WAS OBSERVED BULGING AND STEP CRACKING, THROUGHOUT FACADE. METAL CORNICE MOLDING @ROOF DETERIORATED, DAMAGED, CRACKED, SPALLED MORTAR JOINTS WINDOWS SILLS OBSERVED PARAPET WALLS LE #39155512N | Jun 15, 2026 IN VIOLATION | $2,500 |
| Jul 30, 2025 | Construction CLASS - 1 OBSERVED STRUCTURAL WORK IN PROGRESS, MORE THAN 50 DEMOLISHED, MULTIPLE SISTERING JOIST, AND NEW STRUCTURAL (JOIST) WORK IN PROGRESS. SPECIFICATIONS STATES THAT STRUCTURAL WORK MUST BE PERFORMED AFTER NB OR ALT #39155510J | Jun 15, 2026 IN VIOLATION | $2,500 |
| Mar 19, 2025 | Unknown CLASS - 1 WORK WITHOUT PERMIT. ATOI OBSERVED EXPOSED ELECTRICAL BX HANGING FROM CEILING AT EXPOSURE 4 FIRST FLOOR LEVEL OF BUILDING. NO PERMITS ON FILE WITH THE DEPARTMENT FOR ELECTRICAL WORK., OBTAIN PERMIT #39142210P | May 28, 2025 IN VIOLATION | $1,600 |
| May 31, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: AT EXP#4 BRICKWALL HAS LARGE VERTICAL CRACK AT CORNER OF EXP#1&4 CRACKS RUNS FROM 1ST FL TO 3RD FL ALSO NOTED MORTAR MISSING AT SEVERAL LOCATIONS. #35263623Z | Apr 9, 2018 IN VIOLATION | $0 |
| Feb 19, 2013 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG NOTED 2X12 ACCESSORY SIGN HANGING LOOSE.BLOWING AROUND. REMEDY: REMOVE HAZARD. #35003797H | Jul 8, 2013 WRITTEN OFF | $0 |
| Apr 14, 2012 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED MULTIPLE DEFECTS TO VACANT 3 STORY MIXED USED MASONRY BUILDING. DEFECTS NOTED: AT FRONT OF PREMISES OBSERVED DECORATIVE #34942807L | Jun 4, 2012 WRITTEN OFF | $0 |
| Aug 7, 2009 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG WALLS AND APPURTENANCE FOUND AT THE TIME OF INSP STEP AND VERTICAL RUNNING CRACK APPROX 8'0" FOUND AT EXP#3 REAR FACADE OVER PUBLIC SIDE WALK REM: MAINTAIN EXTERIOR BLDG WALL REPAIR CRA #34796535Y | Sep 28, 2009 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Oct 12, 2023 | CONSTRUCTION COMM'S ORDER APPROX 45 FT MONOPOLE SIGN STRUCTURE REMEDY: OWNER TO IMMEDIATELY ENGAGE A NYS PE EXPERIENCED W/MONOPOLE SIGN STRUCTURES TO INSPECT STRUCTURE INCLUDING VISUAL INSP. ENGINEERING & MATERIALS TESTING EVALUATION OF ALL COMPONENTS OF STRUCTURE & FOUNDATION ETC IMMEDIATELY NOTIFY DOB OF ANY U #23-02847 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)