5 floors · 12 apartments · 10,420 sq ft · built 1910 · class C7 · owner of record: 129 Ave D Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-20 (Accepted). Agency page | Dec 31, 2026 in 66 days | 1 of 2 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 797 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 27, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED IN BASEMENT 2 FUTURE GAS CONNECTIONS.IT HAS A PLUG ON THE RUN SIDE OF THE TEE AND #2 HAS A PLUB ON A REDUCING GAS FITTING.ALSO GAS PIPE IN BOILER R #35555673L | Dec 2, 2021 IN VIOLATION | $1,250 |
| Oct 29, 2020 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER I OBSERVED IN BASEMENT LACK SUPPORT ON GAS PIPE. NO GAS STICKERS ON GAS PIPE. CORROSION ON GAS PIPE USED JIM CAP ON WASTE LINE. ON FIRST FLOOR IN DELI MARKE #39031222K | May 13, 2021 ADMIT/IN-VIO | $0 |
| May 8, 2019 | Construction CLASS - 2 OBSERVED DISREPAIR METAL CORNICE IN ROOF LEVEL AT EXPO # 01 & 02. DECORATIVE 5-DENTAL IN CORNICE DAMAGED AND OPEN. ALSO OBSERVED SPALLING BEND STONE IN 3RD FLOOR LEVEL AT EXPO # 01 AND DISREPAIR METAL FLASHING #39002710R | Sep 12, 2019 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 18, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00011 | DOB VIOLATION - ACTIVE |
| Jan 20, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00014 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Aug 18, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 20, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 31, 2020 | C | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS DROP LADDER OUT OF GUIDE AT FIRE ESCAPE BUILDING FRONT | Sep 6, 2020 |
| Aug 31, 2020 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONER UNIT INSTALLED AT WINDOW 3RD STORY BALCONY AT BUILDING FRONT | Oct 5, 2020 |
| Aug 31, 2020 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONER UNIT INSTALLED AT WINDOW 2ND STORY BALCONY AT BUILDING FRONT | Oct 5, 2020 |
| Aug 31, 2020 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL CORNICE PARAPET WALL AT ROOF AT BUILDING FRONT | Oct 5, 2020 |
| Aug 31, 2020 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONER UNIT INSTALLED AT WINDOW 5TH STORY BALCONY AT BUILDING FRONT | Oct 5, 2020 |
| Aug 31, 2020 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONER UNIT INSTALLED AT WINDOW 4TH STORY BALCONY AT BUILDING FRONT | Oct 5, 2020 |
| Aug 24, 2020 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POTS AT 4 STORY BALCONY, FRONT EAST STACK AT FIRE ESCAPE | Sep 28, 2020 |
| Aug 24, 2020 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POTS AT 5 STORY BALCONY, FRONT EAST STACK AT FIRE ESCAPE | Sep 28, 2020 |
| Jan 10, 2018 | B | Apt 3C · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL AND RETURN BUZZER SYSTEM FROM BUILDING ENTRANCE TO FOYER LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 14, 2018 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 5:04 AM ET. BBL 1003780031.