Staten Island · Block 6544 · Lot 1 · 10312

1270 Hylan Boulevard

2 floors · 100,780 sq ft · built 1964 · class W1 · owner of record: Nyc Department Of Education

13open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
179dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 58 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 100,780 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 179 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 179 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 789 days
Next cycle year 2028
Energy audit and retro-commissioning (2034) Likely applies
Local Law 87 · Calendar year 2034
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 6544). Agency page

Dec 31, 2034
in 2980 days
Next due 2034
Annual boiler inspection (4 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-28 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (8)
IssuedViolationHearingBalance
Apr 6, 2026Construction CLASS - 2
RE-ISSUE #35691915L. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: THE DOORS AND FRAMES AT RM B2 AND B6 ARE VERY RUSTED AND DETERIORATED. THE ROOMS CAN NOT BE USED BECAUSE OF THIS CONDITION. REM
#35727197H
Jun 5, 2026
POP/IN-VIO
$0
Apr 6, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: THERE ARE MANY CHARACTERS WITH HAZARDOUS CONDITIONS. COMBUSTIBLE MATERIALS HANGING FROM CEILINGS AND LIGHTS. ELECTRICAL DEVICES(MICRO WAVE/COFFEE MA
#35727526J
Jun 5, 2026
POP/IN-VIO
$0
Apr 6, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: THERE ARE SEVERAL EMERGENCY LIGHTS THAT WERE NOT OPERATIONAL WHEN TESTED. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1
#35727199L
Jun 5, 2026
POP/IN-VIO
$0
Apr 6, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. RE-ISSUE #35691914J. NOTED: THE CONCRETE WALKWAYS NEED MAJOR ATTENTION AT THE REAR OFTHE BUILDINGS. WITH CRACKS, CHIPS AND MISSING PIECES, CREATING A TRIP
#35727198J
Jun 5, 2026
POP/IN-VIO
$0
Mar 25, 2025Construction CLASS - 2
RE-ISSUE #35674608R. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT REAR OF BUILDINGS, THE CONCRETE WALKWAYS NEED SERVICESATTENTION. CRACKS, CHIPS, AND UNEVEN SURFACES ARE CREATING TRIPPING HA
#35691914J
Apr 30, 2025
POP/IN-VIO
$0
Mar 25, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT BASEMENT LEVEL, RM B2 AND 6 BOTH ARE THE DOORS AND DOOR FRAMES ARE SEVERLY ROTTED, RUSTED AND FALLING APART. NORMAL USE IS IMPOSSIBLE WITH THE PR
#35691915L
Apr 30, 2025
POP/IN-VIO
$0
Apr 4, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT REAR OF BUILDING THE CONCRETE PAVEMENT/WALKWAYS ARE CRACKED, UNEVEN AND BREAKING UP AND SEPARATING AT SEVERAL LOCATIONS CAUSING TRIPPING HAZARD F
#35674608R
Jun 20, 2024
POP/IN-VIO
$0
Mar 24, 2010Boilers CLASS - 1
36
#32068341H
May 19, 2010
WRITTEN OFF
$0
DOB (0)

None open.

DOB NOW Safety (5)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 3, 2026, 8:51 PM ET. BBL 5065440001.