12 floors · 68,865 sq ft · built 1912 · class RC · owner of record: Unavailable Owner
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 47 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 68,865 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $204,500 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 830 days | Filing window not open yet |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 801). Agency page | Dec 31, 2031 in 1873 days | Next due 2031 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-28 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 24, 2026 | Construction CLASS - 1 ATOI OBSERVED THROUGH OUT THE BUILDING OBSERVED OBSTRUCTED SPRINKLER HEADS AND MISSING SPRINKLER CAPS. CONTRARY TO - BC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES THAT SPRINKL #39205547X | Dec 3, 2026 PENDING | $2,500 |
| Sep 24, 2026 | Unknown CLASS - 2 FAILURE TO PROVIDE ADEQUATE GROUNDING OF ELECTRICAL SYSTEMS. OBSERVED IN THE CELLAR MAIN ELECTRICAL RM, AND AT THE MAIN WATER VALVE NO ELECTRODE GROUND ROD INSTALLED AT EITHER LOCATION. MUST PROVIDE A ALTERNATE #39205656P | Dec 3, 2026 PENDING | $2,400 |
| Sep 24, 2026 | Unknown CLASS - 2 FAILURE TO INSTALL GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION AS REQUIRED. OBSERVED IN THE STAFF LAUNDRY ROOM THE WASHERS AND DRYERS ARE NOT PROTECTED BY A GFCI RECEPTACLES. ALL LAUNDRY RM EQUIPMENT MUS #39205655N | Dec 3, 2026 PENDING | $2,400 |
| Oct 6, 2025 | Elevators CLASS - 1 CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION #39162644K | Apr 20, 2027 DEFAULT | $6,250 |
| Oct 6, 2025 | Construction CLASS - 2 OBSERVED ON THE 11 FLOOR BUTTERFLY VALVE INSTALLED ON THE SUCTION SIDE OF THE FIRE PUMP. ALSO FIRE PUMP NOT DRAINING WATER PROPERLY WATER IS ALL OVER THE FLOOR. IN THE BASEMENT LACK OF SPRINKLER COVERAGE BEHIND #39163153K | Dec 18, 2025 IN VIOLATION | $0 |
| Oct 2, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION, NO FIRE STOPPING OBSERVED , THERE ARE EXCESSIVE PENETRATIONS IN BUILDINGS ALSO FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39129805H ISSUED ON 11/07/2025 FOR FAILURE TO MA #39162203P | Jan 15, 2026 IN VIOLATION | $0 |
| Nov 8, 2024 | Construction CLASS - 2 OBSERVED PAINTED SPRINKLER CAPS OVER WASHER MACHINE AND DRYER AREA ON THE 9TH AND 7TH FLOORS ALSO PAINTED SPRINKLER HEAD OVER WASHER AND DRYER ON 5TH FLOOR. AS PER 102.3 OF THE PLUMBING CODE, INSTALLATIONS, BOT #39129824N | Feb 13, 2025 IN VIOLATION | $0 |
| Nov 7, 2024 | Construction CLASS - 2 27-371, BC 715.3.7 (2008 CODE), BC 715.4.8 (2014 CODE), & BC 716.5.9 (2022 CODE) EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING DOORS THROUGHOUT BUILDING. INCASE OF EMERGENCY THIS IS A FIRE OR SMOKE HAZA #39129806J | Feb 13, 2025 IN VIOLATION | $0 |
| Nov 7, 2024 | Unknown CLASS - 2 I OBSERVED IN THE ELECTRICAL CLOSETS ON ALL FLOORS THE INSTALLATION OF DATA WIRING AND EQUIPMENT, AS PER EC 110.25 ONLY ELECTRICAL DISTRIBUTION EQUIPMENT ARE PERMITTED IN THE CLOSETS.; EC 110.25, COMPLY WITH EC #39129823L | Feb 13, 2025 IN VIOLATION | $0 |
| Apr 26, 2024 | Elevators CLASS - 1 CLASS 1: CEASE USE: CAR DOOR DAMAGED & OFF TRACK FROM VANDELISM REPLACE ALL DAMAGED EQUIPMENT (CU). TO RESTORE SERVICE CONTACT NYCDOB AT EIR@BUILDINGS.NYC.GOV. #39112833Y | Jul 11, 2024 IN VIOLATION | $0 |
| Nov 28, 2022 | Construction CLASS - 2 OBSERVED IN THE 2ND BOILER ROOM THAT IS LOCATED IN THE BASEMENT( POTABLE WATER IS ALSO LOCATED IN THIS ROOM) INADEQUATE VENTILATION, AS PER SECTION 304 OF THE FGC BOILER ROOM MUST BE PROPERLY VENTED. ALSO IN TH #39074595N | Jun 8, 2023 IN VIOLATION | $0 |
| Feb 13, 2020 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #801822.REMEDY:SUBMIT ACCEPTABLE REQUIRE #37018448Y | Nov 5, 2020 ADMIT/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 16, 2020 | HAZARDOUS CONDITION (FACADE) #88958 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 5, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Dec 3, 2024 | B | Apt 7 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE 1st ROOM FROM EAST LOCATED AT B-ROOM 7, 7th STORY, 1st B-ROOM FROM NORTH AT EAST | Jan 7, 2025 |
| Dec 3, 2024 | B | Apt 7 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE 1st ROOM FROM EAST LOCATED AT B-ROOM 7, 7th STORY, 1st B-ROOM FROM NORTH AT EAST | Jan 7, 2025 |
| Date | Source | What | Now |
|---|---|---|---|
| Nov 5, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 24, 2026 | ECB | Construction: ATOI OBSERVED THROUGH OUT THE BUILDING OBSERVED OBSTRUCTED SPRINKLER HEADS AND MISSING SPRINKLER CAPS. CONTRARY TO - BC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES THAT SPRINKL | Open |
| Sep 24, 2026 | ECB | Unknown: FAILURE TO PROVIDE ADEQUATE GROUNDING OF ELECTRICAL SYSTEMS. OBSERVED IN THE CELLAR MAIN ELECTRICAL RM, AND AT THE MAIN WATER VALVE NO ELECTRODE GROUND ROD INSTALLED AT EITHER LOCATION. MUST PROVIDE A ALTERNATE | Open |
| Sep 24, 2026 | ECB | Unknown: FAILURE TO INSTALL GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION AS REQUIRED. OBSERVED IN THE STAFF LAUNDRY ROOM THE WASHERS AND DRYERS ARE NOT PROTECTED BY A GFCI RECEPTACLES. ALL LAUNDRY RM EQUIPMENT MUS | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 13, 2026, 6:01 PM ET. BBL 1008017503.