5 floors · 8 apartments · 8,960 sq ft · built 1915 · class C7 · owner of record: Pun & Cheng Realty Corp.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 58 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 74 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 302 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 789 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-07 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 6, 2018 | Construction CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.IN OCTOBER 18,DECEMBER 20,2017.THREE VIOLATIONS WAS ISSUED TO THE RESPONDENT.THE RESPONDENT FAILED TO COMPLY WITH(NYC)ELECTRICAL CODE#27-3018(B) #35313111H | Aug 16, 2018 IN VIOLATION | $0 |
| Dec 20, 2017 | Construction CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. IN OCTOBER 19, 2017. TWO ELECTRICAL VIOLATIONS WAS ISSUE TO THE RESPONDENT. THE RESPONDENT FAILED TO COMPLY WITH(NYC). ELECTRICAL CODE: 27-301 #35274500M | Jul 19, 2018 IN VIOLATION | $0 |
| Oct 20, 2017 | Construction CLASS - 1 WORK WITHOUT A PERMIT. I OBSERVED ON THE GROUND FLOOR KITCHEN AREA PIZZA SHOP. NEWLY INSTALLED GAS PIPING,GAS VALVE FOR A PIZZA OVEN, AND NEW ELECTRICAL HOT WATER HEATER.. ALL THE PLUMBING WORK WAS DONE WITHOUT #35268102X | Mar 29, 2018 IN VIOLATION | $0 |
| Oct 20, 2017 | Plumbing CLASS - 1 FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED. I OBSERVED ON THE GROUND FLOOR KITCHEN AREA PIZZA SHOP, NEWLY INSTALLED GAS PIPING, GAS VALVE FOR A PIZZA OVEN, AND NEW ELECTRICAL HOT WATER HEATER... NO R #35268103H | Mar 29, 2018 IN VIOLATION | $0 |
| Oct 19, 2017 | Unknown CLASS - 1 ELECTRICAL WORK W/O PERMIT.GROUND FLOOR STOREFRONT;BRANCH CIRCUIT WIRING,RECEPTACLES,OUTLETS,SWITCHES,LIGHTING FIXTURES.NOT ON FILE.PLEAS NOTE THIS IS NOT A FINAL INSPECTION.REM:OBTAIN PERMIT. #35274130Y | Mar 29, 2018 IN VIOLATION | $0 |
| Oct 19, 2017 | Unknown CLASS - 1 UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARTUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE.THE ENTIRE PIZZA SHOP INSIDE AND OUTSIDE:EMT ARE NOT SUPPORTED,OUTSIDE OPEN DEFECTIVE WIRING ARE IN USE, #35274133J | Mar 29, 2018 IN VIOLATION | $0 |
| Oct 19, 2017 | Unknown CLASS - 2 ELECTRICAL WORK W/O PERMIT.OUTSIDE TWO ELECTRICAL SIGNS.BRANCH CIRCUIT WIRING,LIGHTING FIXTURES.CONNECTION NOT ON FILE.REM:OBTAIN PERMT. #35274131X | Mar 29, 2018 IN VIOLATION | $0 |
| Aug 14, 2017 | Construction CLASS - 2 WORK W/O A PERMIT. IN LEFT SIDE OF PIZZA STORE WEST FACING 2 SIGNS 1 POSTED IN WALL 6FT LONG 4FT HIGHT IN CANOPY WEST SIDE FACING. 9FT LONG 3FT HIGHT MENTION"ATLANTA TOUR INC" OTHER ONE IN CANOPY SOUTH SIDE FAC #35289950L | Jan 4, 2018 IN VIOLATION | $0 |
| Jun 10, 2015 | Construction CLASS - 2 WORK W/O PERMIT. NOTED: INSTALLED ILLUMINATED ACCESSORY DIGITAL BUSINESS AWNING & 3 SIGNS FOR 127 BUS STATION. REMEDY: OBTAIN ALL NECESSARY PERMITS IF FEASIBLE OR RESTORE PREMISES TO PRIOR LEGAL CONDITION. #35129377P | Jul 30, 2015 STIPULATION/IN-VIO | $0 |
| Feb 27, 2012 | Construction CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS FOR ALT 2 JOB#120175746 OF WHICH PERMIT IS ACTIVE & APPLICANT OF RECORD IS REQUESTING A LETTER OF COMPLETION NON-CONFORMING WORK #34842526R | Jul 5, 2012 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #26540 | DOB VIOLATION - ACTIVE |
| Apr 6, 2018 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT #03895 | DOB VIOLATION - ACTIVE |
| Jan 10, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00016 | DOB VIOLATION - ACTIVE |
| Jan 10, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00019 | DOB VIOLATION - ACTIVE |
| Jan 10, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00018 | DOB VIOLATION - ACTIVE |
| Jan 10, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00017 | DOB VIOLATION - ACTIVE |
| Sep 25, 2017 | CONSTRUCTION FRONT OF THE STORE EAST FACING SIGN,"PIZZA" OTHER SIGN,"ATLANTAS TOUR INC 127" SOUTH FACING SIGN<"BUS STATION 127" #CSPOMD02 | VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE |
| Dec 13, 2011 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT #00229 | DOB VIOLATION - ACTIVE |
| Dec 31, 2009 | LOW PRESSURE BOILER #00273 | DOB VIOLATION - ACTIVE |
| Feb 10, 1997 | LOCAL LAW 62/91 - BOILERS #00626 | DOB VIOLATION - ACTIVE |
| Sep 1, 1994 | LOCAL LAW 62/91 - BOILERS #06030 | DOB VIOLATION - ACTIVE |
| Mar 15, 1990 | ELECTRIC SIGNS #ST11M | DOB VIOLATION - ACTIVE |
| Mar 15, 1990 | ELECTRIC SIGNS #ST13M | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 6, 2018 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT | Active |
| Jan 10, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 10, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 10, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 10, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Dec 31, 2009 | Boiler LBLVIO | Active |
| Feb 10, 1997 | Boiler LL6291 | Active |
| Sep 1, 1994 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 13, 2025 | A | §27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS MISSING | Feb 16, 2026 |
| Nov 13, 2025 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | Feb 16, 2026 |
| Nov 13, 2025 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | Feb 16, 2026 |
| Nov 13, 2025 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT PUBLIC HALL, 1st STORY | Feb 16, 2026 |
| Nov 13, 2025 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Feb 16, 2026 |
| Nov 13, 2025 | A | §27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX MISSING AT PUBLIC HALL, 1st STORY | Feb 16, 2026 |
| Nov 13, 2025 | A | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY | Feb 16, 2026 |
| Nov 13, 2025 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY | Nov 19, 2025 |
| Sep 11, 2025 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SUSPENDED ACCOUSTIC CEILING AT PUBLIC HALL, 1st STORY | Oct 16, 2025 |
| Sep 11, 2025 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT VESTIBULE , 1st STORY | Oct 16, 2025 |
| Sep 11, 2025 | C | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 1st STORY | Sep 17, 2025 |
| Jun 18, 2008 | A | D26-20.07 ADM CODE PROVIDE APPROVED ONE-HOUR FIRE RESISTANCE RATED SELF-CLOSING DOOR AT ALL OPENINGS TO PUBLIC HALL OTHER THAN APT MAIN ENTRANCE DOOR FROM 5 STY AT FRONT. | Sep 21, 2008 |
| Jun 18, 2008 | C | D26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1ST STY PUBLIC HALL NEAR MAILBOXES AND AT DOOR TO BOILER ROOM. | Jun 24, 2008 |
| Jun 18, 2008 | B | Apt 6 · D26-10.01, 10.05 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE 4TH STY REAR WEST APT 6. LOCATED AT APT 6 | Jul 23, 2008 |
| Jun 18, 2008 | B | Apt 5 · D26-10.01, 10.05 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE 4TH STY EAST APT 5. , SECTION '' '' | Jul 23, 2008 |
| Jun 18, 2008 | B | Apt 6 · D26-13.03 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN 4TH STY WEST APT 6 KITCHEN ROACHES & MICE EXCRETA. , SECTION '' '' | Jul 23, 2008 |
| Jun 18, 2008 | B | D26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POTS REAR FIRE ESCAPE BALCONIES 4 & 5 STY. | Jul 23, 2008 |
| Jun 18, 2008 | A | D26-10.01 ADM CODE PROVIDE APPVD IRE PROO SEL CLOSING DOOR WITH KEY OPER DEADBOLT LATCH SET PEEPHOLE CHAIN DOOR GUARD AT ENTRANCE TO 5 STY ALL APTS. | Sep 21, 2008 |
| Jun 18, 2008 | A | D26-10.01 ADM CODE PROVIDE APPVD IREPROO SEL CLOSING DOOR WITH KEY OPER DEADBOLT LATCH SET PEEPHOLE CHAIN DOOR GUARD AT ENTRANCE TO 4 STY ALL APTS. | Sep 21, 2008 |
| Jun 18, 2008 | A | Apt 6 · SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION PANEL PARTITIONS ERECTED SEPARATING ROOMS 2ND 3RD & 4TH ROOM FROM FRNT 4 STY WEST APT 6. LOCATED AT APT 6 | Sep 21, 2008 |
| Jun 18, 2008 | B | Apt 69 · D26-10.01, 10.05 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE 4TH STY WEST APT 69 , SECTION '' '' | Jul 23, 2008 |
| Jun 18, 2008 | B | D26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES 3 STY AT REAR. | Jul 23, 2008 |
| Jun 18, 2008 | A | D26-20.07 ADM CODE PROVIDE APPROVED ONE-HOUR FIRE RESISTANCE RATED SELF-CLOSING DOOR AT ALL OPENINGS TO PUBLIC HALL OTHER THAN APT MAIN ENTRANCE DOOR FROM 4 STY AT FRONT. | Sep 21, 2008 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)