5 floors · 104,643 sq ft · built 1924 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 104,643 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 164 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 164 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 408 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2032) Likely applies Local Law 87 · Calendar year 2032 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1632). Agency page | Dec 31, 2032 in 2235 days | Next due 2032 |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-21 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 20, 2026 | Construction CLASS - 2 EXIT DOOR NOT SELF CLOSING.NOTED EXIT DOOR#4 NOT SELF CLOSING.REM:REPAIR/REPLACE DOOR. #35724873K | Aug 5, 2026 POP/IN-VIO | $0 |
| Jul 20, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED EMERGENCY LIGHTS NOT WORKING AT:AUDITORIUM,2ND FLOOR CORRIDOR#27,#26, #35724872Z | Aug 5, 2026 POP/IN-VIO | $0 |
| Jul 20, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED MISSING GLASS PANEL AT WALL WINDOW BETWEEN CORRIDOR AND CLASSROOM#410.REM:REPAIRAND/OR REPLACE. #35734925M | Aug 5, 2026 POP/IN-VIO | $0 |
| Jul 20, 2026 | Construction CLASS - 2 ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1-28-118.3.2.NOTED TEMPORARY COFO#120777944T009 EXPIRED 10/16/14.NO RENEWED COFO ON DOB FILE.REM:OBTAIN VALID COFO OR D #35734927X | Aug 5, 2026 POP/IN-VIO | $0 |
| Jul 20, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED WATER DAMAGE THROUGHOUT 5TH FLOOR CLASSROOMS:#507,#508,#510,#511,#512 OBSERVED SPALLING PLASTER ON WALLS AND CEILINGS AT STAIRWAY A AND D AT 5TH FLOOR #35734926Y | Aug 5, 2026 POP/IN-VIO | $0 |
| Jul 20, 2026 | Construction CLASS - 2 REISSUED ECB#35724616J FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED AIR POCKETS UNDER ROOFING MEMBRANE,CREATING LEAKS INTO 5TH FLOOR CLASSROOMS.REM:REPAIR AND/OR REPLACE. #35724871R | Aug 5, 2026 POP/IN-VIO | $0 |
| Jul 20, 2026 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS.NOTED AT 2ND FLOOR CLASSROOM#211 AND #212 COMBINED TOGETHER CREATING/USED AS A GYM.REM:DISCONTINUE ILLEGAL USE O #35734928H | Aug 5, 2026 POP/IN-VIO | $0 |
| Jul 20, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:FPSC SMOKEDOORS NOT WORKING PROPERLY AT:CORRIDOR BY ROOM##308,BY EXIT#4.REM:REPAIR AND/OR REPLACE. #35724874M | Aug 5, 2026 POP/IN-VIO | $0 |
| Sep 3, 2025 | Construction CLASS - 2 RE-ISSUE #35684857R. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT THE ROOF, THERE ARE AIR BUCKETS LOCATED ALL THROUGH THE SURFACE. REMEDY: REPAIR/REPLACE. #35724616J | Oct 14, 2025 POP/IN-VIO | $0 |
| Aug 19, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES.NOTED:AT ROOF TOPAIR PACKETS ARE PRESENT THROUGHOUT THE ROOF.REM:MAKE NECESSARY REPAIRS #35684857R | Oct 24, 2024 POP/IN-VIO | $0 |
| May 27, 2021 | Elevators CLASS - 2 CLASS 2 VIOLATION ISSUED LOWER LANDING CHAIR LIFT DOOR SLAM WHENEVER IT CLOSE IN REMEDY; REPAIR #39041851M | May 29, 2021 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Report | Active |
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 11) | Active |
| Sep 11, 2024 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 18, 2026, 12:30 PM ET. BBL 1016320011.