4 floors · 42,208 sq ft · built 1925 · class HH · owner of record: 127-03 20th Ave Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 57 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 42,208 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 178 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 178 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1153 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 17, 2026 | Elevators CLASS - 1 CLASS 1 C/U: DOOR ZONE RESTRICTOR MALFUNCTIONING AS PER ASME A17.1 2.12.5. THIS SAFETY FEATURE PREVENTS CAR DOORS FROM OPENING WHEN THE CAR IS OUT OF THE DOOR ZONE. WATER IN PIT SUBMERGING GOVERNOR TENSION SHEA #39196542P | Sep 22, 2026 IN VIOLATION | $1,250 |
| Nov 1, 2014 | Construction CLASS - 2 PROJECT INFORMATION PANEL.NOT PROVIDED.NOTE:DEMO SITE BLDG DOWN TO GRADE SITE FELLED.FENCE ERECTED ON EXP.1 FOR APPROX.140FT @ 4'HIGH.NO PR OJECT INFO PANEL ON JOBSITE FENCE @ STREET EXP.#1 ALONG 128 ST.REM:PRO #35109552P | Dec 16, 2014 IN VIOLATION | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Aug 31, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 7) | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 7) | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 31, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 17, 2026 | ECB | Elevators: CLASS 1 C/U: DOOR ZONE RESTRICTOR MALFUNCTIONING AS PER ASME A17.1 2.12.5. THIS SAFETY FEATURE PREVENTS CAR DOORS FROM OPENING WHEN THE CAR IS OUT OF THE DOOR ZONE. WATER IN PIT SUBMERGING GOVERNOR TENSION SHEA | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 4, 2026, 8:15 PM ET. BBL 4041330001.