Bronx · Block 2450 · Lot 40 · 10456

1261 Morris Avenue

3 floors · 11,250 sq ft · built 1940 · class Y1 · owner of record: Fire Department Of New York

4open violations
$2,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
62dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 62 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-11 (Accepted). Agency page

Dec 31, 2026
in 62 days
1 of 1 without an accepted 2026 report yet

Open violations

ECB / OATH (1) · $2,500 owed
IssuedViolationHearingBalance
Aug 6, 2026Unknown CLASS - 2
AT TIME OF INSPECTION, OBSERVED ACTIVE PROPOSED 3-STORY BUILDING IN STRUCTURAL PHASE. MISSING/INADEQUATE TOE BOARDS OBSERVED AT ELEVATOR SHAFT OPENING IN CELLAR, CONTRARY TO BC 3308.7.2. CONDITION EXPOSES WORKE
#39557635P
Jan 21, 2027
PENDING
$2,500
DOB (0)

None open.

DOB NOW Safety (2)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 4)
Active
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 4)
Active
HPD (1) · C 0 · B 1 · A 0
IssuedClassViolationCorrect by
Sep 28, 2007BApt 51 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING OVER STOVE IN THE KITCHEN LOCATED AT APT 51, 5th STORY, 1st APARTMENT FROM WEST AT NORTHNov 2, 2007

Issued in the last 120 days

DateSourceWhatNow
Aug 6, 2026ECBUnknown: AT TIME OF INSPECTION, OBSERVED ACTIVE PROPOSED 3-STORY BUILDING IN STRUCTURAL PHASE. MISSING/INADEQUATE TOE BOARDS OBSERVED AT ELEVATOR SHAFT OPENING IN CELLAR, CONTRARY TO BC 3308.7.2. CONDITION EXPOSES WORKEOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 4:35 PM ET. BBL 2024500040.