17 floors · 278,905 sq ft · built 1898 · class H2 · owner of record: Martinque Htl Affiliates
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $208,500 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 122 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 278,905 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 191 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 191 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1166 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 834). Agency page | Dec 31, 2034 in 2992 days | Next due 2034 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-29 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 24, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED DELTA OUTRIGGER BEAMS NOT INSTALLED AS PER MANUFACTURE SPECIFICATION. DELTA BEAM CONFORM IN THREE PIECES BUT ONLY TWO WERE INSTALLED. ALSO OBSERVED SKYCLIMBER MODULAR PLATFORM 3 M #39552174Z | Jan 21, 2027 | $1,250 |
| Mar 24, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED INSTATE OF DISREPAIR. SUPPORTED SCAFFOLD ON TOP OF SIDEWALK SHED, DUE TO LOAD AND CONDITION OF PLANKS, NOTICE PLANKS BROKEN SCREW JACKS HAVE PENETRATE PLANKS. ALSO #39552177Y | Jan 21, 2027 | $5,000 |
| Mar 24, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION ON ACTIVE SITE COMPETENT PERSON WAS UNABLE TO PROVIDED THE FOLLOWING DOCUMENTS. STRUCTURAL STABILITY LETTER FOR THE USE OF PARAPET CLAMPS. PRE AND POST INSTALLATION LETTER FOR ALL LOCATION #39552173R | Jan 21, 2027 | $1,250 |
| Mar 12, 2026 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION AS NOTED:AT TIME OF INSPECTION I OBSERVED ON PIPE SCAFFOLDING DAMAGED,LOOSE,TORE NETTING.REM:COMPLY WITH CODE SPECIFICATIONS.SECURE & REPAIR TORE NETTING. #35726804X | May 20, 2026 IN VIOLATION | $2,400 |
| Dec 26, 2025 | Unknown CLASS - 1 FAILURE TO COMPLY AND MAINTAIN AS PER CODE SPECIFICATIONS. OBSERVED SUPPORTED SCAFFOLD WITH LOSE NETTING BY ADJACENT BUILDING ON SEVERAL LEVELS WERE NOT COMPLYING WITH THE REQUIRED SAFETY STANDARDS, CREATING AN #39548503Z | Apr 19, 2027 | $5,000 |
| Nov 28, 2023 | Elevators CLASS - 1 CLASS 1 ,CAR CEASE USE ,5/M/7 CAR DOOR RESTRICTOR MISSING PROVIDE #39100193R | Feb 1, 2024 ADMIT/IN-VIO | $0 |
| Jun 20, 2017 | Unknown CLASS - 2 FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000005345 HASBEEN INSPECTED,TESTED,AND DISINFECTED AND THAT A MAINTENANCE PLAN HAS BEEN DEVELOPED AND IMPLEMENTED BY NOVEMBER,1,2016.REM:FILE ANNUAL CERT #37003152N | Nov 15, 2018 IN VIOLATION | $0 |
| Feb 10, 2016 | Construction CLASS - 2 3307.6.5 FAILURE TO MAINTAIN SIDEWALK SHED AS REQUIRED BY CODE. NOTE AT TIME OF INSPECTION,SIDEWALK SHED ERECTED UNDER JOB #140173979 ALONGEXP 1 AND 2. ALSO THERE IS INADEQUATE ILLUMINATION BENEATH SIDEWALK SH #35170771H | Mar 31, 2016 STIPULATION/IN-VIO | $0 |
| Jul 15, 2008 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR OF BLDG EAST ELEVATION SHOWS EXTENSIVE CRACKS. IN PARAPET BULGING & PULLING AWAY; STEP CRACKS, DETERIORATING INTERRA COTTA, COPING STONE ROOF LINE; VERTICAL CRACKS ON SLOPING COPING #34683575H | Dec 4, 2008 IN VIOLATION | $0 |
| Apr 5, 1989 | Public Assembly Unknown OPERATION OF PA WITHOUT A CURRENT PERMIT REMEDY OBTAIN A PERMIT BN223/84 NOT SIGNED OFF REMEDY HAVE BN 223/84 SIGNED OFF #34018659P | May 18, 1989 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 12, 2026 | CONSTRUCTION FTM BLDG. OBSERVED AT EXP 2 W.ELEV: CRACKS IN MASONARY. EXP 3 N.ELEV: BOARDED WINDOW AND CRACKS. EXP 4 E.ELEV STEP CRACKS NEAR PARAPET WALL AND ERRODED MORTAR JOINTS. ROOF AREA STEP CRACKS IN CHIMNEY ROTTED METAL COMPONENT OF CHIMNEY. REMEDY: REPAIR AND/OR REPLACE DEFECTIVE CONDITIONS #SR0503RF | DOB VIOLATION - ACTIVE |
| Feb 7, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00049 | DOB VIOLATION - ACTIVE |
| Dec 1, 2023 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2300197 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #44117 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #40276 | DOB VIOLATION - ACTIVE |
| Feb 21, 2022 | HAZARDOUS CONDITION (FACADE) CYCLE 9A UNSAFE REPORT FILED #910016 | DOB VIOLATION - ACTIVE |
| Feb 14, 2017 | FACADE SAFETY PROGRAM #HAZ86521 | DOB VIOLATION - ACTIVE |
| Aug 5, 2015 | LANDMARK #16-0139 | DOB VIOLATION - ACTIVE |
| Jan 3, 2013 | LL11/98-LOCAL LAW 11/98 - FACADE CYCLE 7 UNSAFE REPORT #HAZ73875 | DOB VIOLATION - ACTIVE |
| Oct 1, 2012 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST #00669 | DOB VIOLATION - ACTIVE |
| Aug 15, 2012 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2010 CAT 1 INSP/TST #00157 | DOB VIOLATION - ACTIVE |
| Jul 2, 2008 | CONSTRUCTION #MTF01RNS | DOB VIOLATION - ACTIVE |
| Mar 21, 2008 | LOCAL LAW 10/81 - ELEVATOR #00716 | DOB VIOLATION - ACTIVE |
| Nov 19, 2004 | LOCAL LAW 10/81 - ELEVATOR #00534 | DOB VIOLATION - ACTIVE |
| Apr 21, 2004 | LOCAL LAW 10/81 - ELEVATOR #00598 | DOB VIOLATION - ACTIVE |
| Jan 30, 2001 | CONSTRUCTION #STF05FMS | DOB VIOLATION - ACTIVE |
| Jan 30, 2001 | CONSTRUCTION #ZSTF08FMS | DOB VIOLATION - ACTIVE |
| Jan 30, 2001 | CONSTRUCTION #ZSTF07FMS | DOB VIOLATION - ACTIVE |
| Jan 30, 2001 | CONSTRUCTION #STF06FMS | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #00629 | DOB VIOLATION - ACTIVE |
| Jan 10, 1994 | CONSTRUCTION #MTF8LE | DOB VIOLATION - ACTIVE |
| Jan 10, 1994 | CONSTRUCTION #MTF7LE | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Apr 20, 2026 | GHG Emissions - LL97 FTF-EN-LL97320 | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Feb 7, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 1, 2023 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Feb 21, 2022 | Facades FISPHAZ CYCLE 9A UNSAFE REPORT FILED | Active |
| Feb 14, 2017 | Facades FISP CYCLE 8A UNSAFE REPORT FILED | Active |
| Jan 3, 2013 | Facades LL11/98 CYCLE 7 UNSAFE REPORT | Active |
| Oct 1, 2012 | Elevators EVCAT1 | Active |
| Oct 1, 2012 | Elevators EVCAT1 | Active |
| Oct 1, 2012 | Elevators EVCAT1 | Active |
| Oct 1, 2012 | Elevators EVCAT1 | Active |
| Oct 1, 2012 | Elevators EVCAT1 | Active |
| Aug 15, 2012 | Elevators ACC1 | Active |
| Aug 15, 2012 | Elevators ACC1 | Active |
| Aug 15, 2012 | Elevators ACC1 | Active |
| Aug 15, 2012 | Elevators ACC1 | Active |
| Aug 15, 2012 | Elevators ACC1 | Active |
| Aug 15, 2012 | Elevators ACC1 | Active |
| Aug 15, 2012 | Elevators ACC1 | Active |
| Aug 15, 2012 | Elevators ACC1 | Active |
| Aug 15, 2012 | Elevators ACC1 | Active |
| Aug 15, 2012 | Elevators ACC1 | Active |
| Aug 15, 2012 | Elevators ACC1 | Active |
| Aug 15, 2012 | Elevators ACC1 | Active |
| Mar 21, 2008 | Elevators LL1081 | Active |
| Mar 21, 2008 | Elevators LL1081 | Active |
| Mar 21, 2008 | Elevators LL1081 | Active |
| Mar 21, 2008 | Elevators LL1081 | Active |
| Mar 21, 2008 | Elevators LL1081 | Active |
| Nov 19, 2004 | Elevators LL1081 | Active |
| Nov 19, 2004 | Elevators LL1081 | Active |
| Nov 19, 2004 | Elevators LL1081 | Active |
| Nov 19, 2004 | Elevators LL1081 | Active |
| Nov 19, 2004 | Elevators LL1081 | Active |
| Apr 21, 2004 | Elevators LL1081 | Active |
| Apr 21, 2004 | Elevators LL1081 | Active |
| Apr 21, 2004 | Elevators LL1081 | Active |
| Apr 21, 2004 | Elevators LL1081 | Active |
Showing 60 of 68. Full list on the agency site.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 2, 2022 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Nov 15, 2023 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Nov 22, 2024 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Nov 17, 2025 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Apr 29, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 2, 2026 |
| Jun 4, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 7, 2025 |
| Apr 1, 2024 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 5, 2024 |
| Mar 15, 2023 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jun 18, 2023 |
| Feb 15, 2022 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | May 21, 2022 |
| Jun 30, 2008 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DAMPNESS PENETRATING CEILING & WALL BATHROOM ROOM 538 5 STY FRONT SECTION. | Aug 4, 2008 |
| Jun 30, 2008 | B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING & WALLS 5 STY FRONT SECTION ROOM 538. | Aug 4, 2008 |
| Jun 30, 2008 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED BX CABLE AT WALLS 5 STY FRONT SECTION ROOM 538. | Aug 4, 2008 |
| Jun 30, 2008 | C | § 27-2005 ADM CODE PROVIDE APPLICATION & LEGALIZATION OF CONDITION OR DISCONTINUE USE OF ELECTRIC HOT WATER HEATER AT 5 STY ROOM 538. | Jul 6, 2008 |
| Jun 30, 2008 | B | § 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION OCCUPANCY OF 16 STY INCREASED FROM 23 ROOMS TO 26 ROOMS CONTRARY TO C OF O 67172. | Aug 4, 2008 |
| Jun 30, 2008 | B | § 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION OCCUPANCY OF 2 STY INCREASED FROM 9 TO 15 ROOMS CONTRARY TO C OF O 67172. | Aug 4, 2008 |
| Aug 30, 2007 | C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF NO PUBLIC HALL ELECTRICAL LIGHT BLDG THRU OUT. | Sep 5, 2007 |
| Aug 30, 2007 | C | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES PUBLIC HALL WATERCLOSET WASHBASIN SHOWER AND BATHROOM ALL STYS. | Sep 5, 2007 |
| Aug 30, 2007 | C | § 187 M/D LAW PROVIDE A SPRINKLER SYSTEM OR A LEGAL SECOND MEANS OF EGRESS AND FILE APPLICATION FOR APPROVAL BEFORE DOING THIS WORK PUBLIC HALL ALL STYS. | Sep 5, 2007 |
| Aug 30, 2007 | C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF NO WATER SUPPLY TO STAND PIPE SYSTEM PUBLIC HALL ALL STYS. | Sep 5, 2007 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)