Brooklyn · Block 5049 · Lot 17 · 11225

126 Winthrop Street

3 floors · 4 apartments · 5,500 sq ft · built 1910 · class C3 · owner of record: Mzw Management Group Llc

2open violations
$19,425ECB/OATH penalties owed
0HPD class C (immediately hazardous)
59dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 59 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 59 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 59 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 75 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 303 days
Registered through 2027-09-01

Open violations

ECB / OATH (7) · $19,425 owed
IssuedViolationHearingBalance
Jul 25, 2024Unknown CLASS - 1
OBSERVED SUPPORTED SCAFFOLD ON SEVERAL AREA BEEN IN USE WITHOUT A PROPER INSTALLATION MISSING GUARDRAIL, MUDSILLS, BRACES, PLANKS, AND TEABOARD. PERMITHOLDER FAILED TO PROVIDE THE SAFE SCAFFOLDS CREATING HAZARD
#39530796X
Dec 1, 2026
$5,030
Jul 25, 2024Construction CLASS - 2
OBSERVED DEBRIS CONTAINER AT EXPOSURE ONE STREET STORAGE AREA, PERMITHOLDER FAILED TO PROVIDE PROTECTION FENCE BETWEEN WALKWAY AND SUCH AREA, FAILED TO CODE REQUIREMENT FOR 3307.4.7 ADJACENT TO A SIDEWALK SHED,
#39530795Y
Dec 1, 2026
$2,400
Jul 25, 2024Construction CLASS - 1
OBSERVED AREAS AND STRAINS WERE IN USE ON 2ND AND 3RD FLOORS MISSING GUARDRAILS OR EQUIVALENTS, IN CONTRARY WITH BC3301.2 ALSO NO HANDRAILS ON STAIRS CREATING AN IMMEDIATE HAZARDOUS FOR ANYONE ENTERING THE AREA
#39530797H
Dec 1, 2026
$5,000
Dec 21, 2023Construction CLASS - 2
VERTICAL EXTENSION OF 1 STORY ON EXISTING 3 STORY BUILDING. AT TIME OF INSPECTION WAS REQUIRED A ORIENTATION LOG BOOK TO CP NONE WAS PROVIDED .
#39524295R
Dec 4, 2026
$1,280
Dec 21, 2023Unknown CLASS - 2
VERTICAL ONE STORY EXTENSION OF EXISTING 3 STORY BUILDING CONVERT TO 4 STORY .UPON INSPECTION WAS CHECKED ENTIRE SITE AND FOUND MISSING FIRE EXTINGUISHERS ON FLOORS . CONTRARY TO NYC FIRE CODE/ STOP ALL WORK U
#39524289K
Dec 4, 2026
$655
Dec 21, 2023Unknown CLASS - 2
VERTICAL 1 STORY EXTENSION OF EXISTING 3 STORY BUILDING .AT TIME OF INSPECTION OBSERVED: ACTIVE SITE CP PRESENT UPON INSPECTION NOTED SEVERAL HOLES ON DIFFERENT FLOORS LEVELS ,CREATING HAZARDS CONDITIONS FOR WO
#39524296Z
Dec 4, 2026
$2,530
Dec 21, 2023Unknown CLASS - 2
VERTICAL ONE STORY EXTENSION CONVER 3 STORY RESIDENTIAL TO 4 STORY ACTIVE SITE AND PERMIT CP PRESENT UPON INSPECTION OBSERVED: 5 WORKERS ON SITE WITHOUT SANITARY FACILITIES .SANITARY FACILITIES SHALL BE PROVI
#39524288Z
Dec 4, 2026
$2,530
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 9)
Active
HPD (1) · C 0 · B 0 · A 1
IssuedClassViolationCorrect by
May 6, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 9, 2026

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 2, 2026, 8:47 PM ET. BBL 3050490017.