| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 14, 2026 | Construction CLASS - 2 WORK DOES NOT CONFORM TO PLANS. AT EXPOSURE 4, BETWEEN STAIRS A AND B, WALL TYPE EX-3 ON ARCH AND WALL TYPE WT-02A.1 REQUIRES R-15 CAVITY INSULATION. CONTRACTOR INSTALLED R-8 INSULATION., CONFORM WORK TO APPROV #39207831M | Dec 24, 2026 PENDING | $1,250 |
| Sep 25, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION, OBSERVED AREA BELOW SUSPENDED SCAFFOLD AT SETBACK ON THE CORNER OF EXPOSURES 2 AND 3 WITHOUT OVERHEAD PROTECTION AND REQUIRED CAZ NOT MAINTAINED, CONTRARY TO BC 3301.2, CREATING FALLING-O #39559682R | Dec 3, 2026 PENDING | $5,000 |
| Sep 25, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED SUSPENDED SCAFFOLD NOT INSTALLED PER APPROVED CONSTRUCTION DOCUMENTS, CONTRARY TO AC 28-105.12.2. APPROVED DRAWING REQUIRES TWO WIRE-ROPE LINES AT EACH OUTRIGGER, ONE ON THE THIM #39559679X | Dec 3, 2026 PENDING | $2,500 |
| Sep 25, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, OBSERVED GARBAGE REMOVAL OPERATIONS BEING CONDUCTED IN THE STREET AND SIDEWALK WITHOUT A REQUIRED FLAG PERSON, CONTRARY TO BC 3307.4.4, FAILING TO PROVIDE TRAFFIC CONTROL AND PROTECTION D #39559680N | Dec 3, 2026 PENDING | $2,400 |
| Sep 25, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION, OBSERVED REQUIRED VERTICAL SAFETY NETTING AT MULTIPLE FLOORS AND EXPOSURES NOT PROPERLY MAINTAINED, CONTRARY TO BC 3308.5. OBSERVED LOOSE NETTING AND MISSING AND LOOSE CABLES, RESULTING I #39559681P | Dec 3, 2026 PENDING | $10,000 |
| Aug 18, 2026 | Construction CLASS - 2 RESPONDING TO AN INCIDENT THAT OCCURRED ON 08-12-2026 AT APPROX. 5:30 PM WERE AN ELECTRICAL PALLET JACK RIDE OVER A WORKER FOOT WHILE HE WAS MOVING IT. INSPECTION REVEALED THAT THE WORKER DID NOT HAVE PROPER TR #39558096J | Jun 1, 2027 | $5,000 |
| Jul 20, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OF PROPOSED 25 STORY BUILDING OBSERVED BROKEN WINDOW AT 123 LAFAYETTE ST FROM UNSAFE CONCRETE OPERATIONS WHERE IT WAS REPORTED WHILE CLEANING CONCRETE HOSE BALL WAS CAUGHT AND CONNECTION W #39556836R | Nov 12, 2026 | $10,000 |
| May 1, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OF A PROPOSED 25 STORIES BUILDING AT 4 STORIES FRAMING LEVEL, I OBSERVED PEDESTRIAN SIDEWALK WAS BLOCKED CAUSING THE PEDESTRIAN TO WALK UNDER THE SIDEWALK SHED WHICH WAS INSTALLED INSIDE T #39553733K | Mar 4, 2027 | $2,500 |
| Apr 17, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, IT WAS NOTED THAT ON FEBRUARY 17, 2026, AN INCIDENT INVOLVING WORKER KENY JOSE BOLANOS WAS REPORTED TO HAVE OCCURRED AT THE JOB SITE, AND THE GENERAL CONTRACTOR FAILED TO IMMEDIATELY NOTI #39553143K | Jan 8, 2027 | $5,000 |
| Apr 17, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION, IT WAS NOTED THAT ON 02/17/2026, AN INCIDENT INVOLVING WORKER KENY JOSE BOLANOS WAS REPORTED TO HAVE OCCURRED AT THE JOB SITE, AND THE GENERAL CONTRACTOR FAILED TO NOTIFY THE DEPARTMENT A #39553144M | Jan 8, 2027 | $10,000 |
| Apr 7, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION, I OBSERVED WORKERS ERECTING A DECK AT THE 1ST FLOOR. WORKERS WERE USING PERSONAL FALL ARREST SYSTEMS WITH LIFELINES CLIPPED ONTO REBAR STIRRUPS AS ANCHORAGE. STIRRUPS ARE NOT DESIGNED #39552712R | Feb 8, 2027 | $5,000 |
| Dec 1, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION, THE SITE SAFETY PLAN DID NOT INCLUDE A REQUIRED CONTROLLED ACCESS ZONE (CAZ). NO ACCESS AGREEMENT WAS IN PLACE WITH THE ADJOINING PROPERTY. SUSPENDED SCAFFOLD WAS PRESENT ABOVE EXPOSURE 4 #39547469J | Mar 18, 2027 | $2,500 |
| Apr 11, 2023 | Unknown CLASS - 1 FAILURE TO NOTIFY THE DEPARTMENT OF AN ACIDENT.INCIDENT THAT RESULTED IN A FATALITY OR AN INJURY.NOTE:4 WORKERS WERE SUFFERED INJURY WHEN DOING DEMOLITION WALL COLLAPSE OR THE 2ND FLOOR WORKERS WERE TAKEN TO HO #35653999K | Jul 20, 2023 DEFAULT | $0 |
None open.
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 14, 2026 | ECB | Construction: WORK DOES NOT CONFORM TO PLANS. AT EXPOSURE 4, BETWEEN STAIRS A AND B, WALL TYPE EX-3 ON ARCH AND WALL TYPE WT-02A.1 REQUIRES R-15 CAVITY INSULATION. CONTRACTOR INSTALLED R-8 INSULATION., CONFORM WORK TO APPROV | Open |
| Sep 25, 2026 | ECB | Unknown: AT TIME OF INSPECTION, OBSERVED AREA BELOW SUSPENDED SCAFFOLD AT SETBACK ON THE CORNER OF EXPOSURES 2 AND 3 WITHOUT OVERHEAD PROTECTION AND REQUIRED CAZ NOT MAINTAINED, CONTRARY TO BC 3301.2, CREATING FALLING-O | Open |
| Sep 25, 2026 | ECB | Construction: AT TIME OF INSPECTION, OBSERVED SUSPENDED SCAFFOLD NOT INSTALLED PER APPROVED CONSTRUCTION DOCUMENTS, CONTRARY TO AC 28-105.12.2. APPROVED DRAWING REQUIRES TWO WIRE-ROPE LINES AT EACH OUTRIGGER, ONE ON THE THIM | Open |
| Sep 25, 2026 | ECB | Construction: AT TIME OF INSPECTION, OBSERVED GARBAGE REMOVAL OPERATIONS BEING CONDUCTED IN THE STREET AND SIDEWALK WITHOUT A REQUIRED FLAG PERSON, CONTRARY TO BC 3307.4.4, FAILING TO PROVIDE TRAFFIC CONTROL AND PROTECTION D | Open |
| Sep 25, 2026 | ECB | Unknown: AT TIME OF INSPECTION, OBSERVED REQUIRED VERTICAL SAFETY NETTING AT MULTIPLE FLOORS AND EXPOSURES NOT PROPERLY MAINTAINED, CONTRARY TO BC 3308.5. OBSERVED LOOSE NETTING AND MISSING AND LOOSE CABLES, RESULTING I | Open |
| Aug 18, 2026 | ECB | Construction: RESPONDING TO AN INCIDENT THAT OCCURRED ON 08-12-2026 AT APPROX. 5:30 PM WERE AN ELECTRICAL PALLET JACK RIDE OVER A WORKER FOOT WHILE HE WAS MOVING IT. INSPECTION REVEALED THAT THE WORKER DID NOT HAVE PROPER TR | Closed |
| Jul 20, 2026 | ECB | Construction: AT TIME OF INSPECTION OF PROPOSED 25 STORY BUILDING OBSERVED BROKEN WINDOW AT 123 LAFAYETTE ST FROM UNSAFE CONCRETE OPERATIONS WHERE IT WAS REPORTED WHILE CLEANING CONCRETE HOSE BALL WAS CAUGHT AND CONNECTION W | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 11, 2026, 5:19 PM ET. BBL 1002090021.