Queens · Block 12104 · Lot 1 · 11436

126-28 149 Street

3 floors · 52,065 sq ft · built 1928 · class W1 · owner of record: Nyc Department Of Education

18open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
163dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 42 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 52,065 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 163 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 163 days
Annual filing
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 407 days
Next cycle year 2027
Energy audit and retro-commissioning (2034) Likely applies
Local Law 87 · Calendar year 2034
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 12104). Agency page

Dec 31, 2034
in 2964 days
Next due 2034
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-20 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (11)
IssuedViolationHearingBalance
May 26, 2026Construction CLASS - 2
REISSUE ON ECB#35725401R FAILURE TO MAINTIAN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:EMERGENCY EXIT DISCHARGES AND EXIT SIGNS WER
#35733099P
Jul 15, 2026
POP/IN-VIO
$0
May 26, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:FIRE RATEDCLASSROOMS AND SMOKE DOORS NOT SELF-CLOSING DUE TO BINDING,MISSING ANDOR FAULTY HARDWARE ON CLASSROOMS 213,216,204,206,207,108,102,103 OBSER
#35733051X
Jul 15, 2026
POP/IN-VIO
$0
May 26, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT EXIT 6 WIRE MESH GLASS PANELS ARE CRACKED ON 2 DIFFERENT LOCATIONS WITH A TOTAL OF 4 PANELS IN TOTAL OBSERVED UPON INSPECTION.REM:REPAIR AND/OR REP
#35733054L
Jul 15, 2026
POP/IN-VIO
$0
May 26, 2026Construction CLASS - 2
REISSUE ON ECB#35725400P FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT 1ST FLOOR AUDITORIUM EXIT AT STAIRWAY F CEILING IN VESTIBULE IS IN DISREPAIR DUE TO SPALLING PLASTER IN VARIOUS LOCATIONS
#35733050Y
Jul 15, 2026
POP/IN-VIO
$0
May 26, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NO FIRE STOPPINGPER BC 712.3;27-345.NOTED:MISSING FIRE STOPPING IN ELECTRICAL SWITCH GEAR ROOM WALLS AT VARIOUS POINTS THROUGOUT OBSERVED UPON INSPECTION.RE
#35733053J
Jul 15, 2026
POP/IN-VIO
$0
May 26, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:IN CAFETERIA HAS LIVE ELECTRIC CORD PLUGGED IN TO AN OUTLET RUNNING THROUGH 1ST FL CAFETERIA SMOKE DOORS INTO VESTIBULE PINCHING THE WIRE ON METAL DOO
#35733052H
Jul 15, 2026
POP/IN-VIO
$0
Sep 26, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITSM EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. AT THE TIME OF INPECTION OBSERVED AND NOTED AT 2ND. FLOOR AT GYM 6 PLAC
#35725401R
Oct 23, 2025
POP/IN-VIO
$0
Sep 26, 2025Construction CLASS - 2
REISSUE: 35655440Z DATE OF ISSUE: 06-09-2022. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED AND NOTED AT 1ST FLOOR AUDITORIUM EXIT STAIRWAY 'F' CEILING IN VESTIBULE I
#35725400P
Oct 23, 2025
POP/IN-VIO
$0
Jun 28, 2024Construction CLASS - 2
REISSUE #35655440Z. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT 1ST FL AUDITORIUM EXIT #10/STAIR F. CEILING SPALLING PLASTER IN VARIOUS LOCATIONS AND A HOLE IN CEILING APPROX 3SQFT. INTERIOR
#35682887Z
Aug 19, 2024
POP/IN-VIO
$0
Jun 28, 2024Construction CLASS - 2
EXIT DOOR NOT SELF-CLOSING. NOTED EXTERIOR DOORS AT EXITS #3, 10, 4 AND 2, NOT SELF-CLOSING PROPERLY DUE TO RUBBING ON FRAME OR SADDLE AND DEFECTIVE HARDWARE. REMEDY: REPAIR/REPLACE DOORS.
#35682886R
Aug 19, 2024
POP/IN-VIO
$0
Jun 9, 2022Construction CLASS - 2
RE-ISSUE #35561033Y FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:NOTED:OBSERVED AT 1ST FLOOR AUDITORIUM(EXIT)STAIRWAY "F" CEILING IN VESTIBLUE IN STATE OF DISREPAIR DUE TO SPALLING PLASTER IN VARIOUS L
#35655440Z
Oct 25, 2022
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (7)
IssuedViolationStatus
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 19, 2026, 5:48 AM ET. BBL 4121040001.