Brooklyn · Block 3430 · Lot 49 · 11207

1259 Decatur Street

3 floors · 6 apartments · 4,725 sq ft · built 1910 · class C2 · owner of record: Pose Corp.

35open violations
$0ECB/OATH penalties owed
6HPD class C (immediately hazardous)
57dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 57 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 57 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 57 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 73 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 301 days
Registered through 2027-09-01
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-01 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (2)
IssuedViolationHearingBalance
Jul 29, 2020Construction CLASS - 2
FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES.AT TIME OF INSPECTION OBSERVED FACADE AT FRONT AND LEFT SIDE OF BLDG HAS DEFECTS IN BRICKS WITH RUNNING CRACKS MISSING MORTAR AT JOINTS,CRACKS INTO KEYSTONE,LIN
#35478056J
Jan 20, 2021
IN VIOLATION
$0
Feb 26, 2001Quality of Life Hazardous
RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED NUMBER OF FAM.3FL WALK UP WITH TWO LEGAL APT ON EACH FL HAS NON BEEN ALTEREED WITH NEW ADDITIONAL DOOR ONE ON FIRST FL RIGHT SIDE
#34273622J
Jun 10, 2002
WRITTEN OFF
$0
DOB (8)
IssuedViolationStatus
Feb 28, 2020CONSTRUCTION
STRUCTURE RENDERED NON-COMPLIANT AT TIME OF INSPECTION DAMAGE OBSERVED APPEARS TO HAVE BEEN CAUSED BY ON GOING EXCAVATION AT ACTIVE SITE AT 1255 DECATUR STREET DAMAGE OBSERVED AT APARTMENT 1L WITH SEVERAL INTERIOR CRACKS AT EXPOSURE #2
#ER03MP
DOB VIOLATION - ACTIVE
Jan 31, 2005LOCAL LAW 62/91 - BOILERS

#18927
DOB VIOLATION - ACTIVE
Feb 13, 2004LOCAL LAW 62/91 - BOILERS

#20126
DOB VIOLATION - ACTIVE
Mar 19, 2003LOCAL LAW 62/91 - BOILERS

#19431
DOB VIOLATION - ACTIVE
Mar 26, 2002LOCAL LAW 62/91 - BOILERS

#20795
DOB VIOLATION - ACTIVE
Feb 27, 2001LOCAL LAW 62/91 - BOILERS

#19631
DOB VIOLATION - ACTIVE
Feb 26, 2001CONSTRUCTION
HAZARDOUS
#04HS01
DOB VIOLATION - ACTIVE
Feb 7, 2000LOCAL LAW 62/91 - BOILERS

#20046
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Jan 19, 2007Boiler LL6291
Active
Jan 31, 2005Boiler LL6291
Active
Feb 13, 2004Boiler LL6291
Active
Mar 19, 2003Boiler LL6291
Active
Mar 26, 2002Boiler LL6291
Active
Feb 27, 2001Boiler LL6291
Active
Feb 7, 2000Boiler LL6291
Active
HPD (18) · C 6 · B 10 · A 2
IssuedClassViolationCorrect by
Mar 15, 2022C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM . AT BOILER ROOMMar 21, 2022
Sep 10, 2020BApt 2L · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL, WEST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHOct 15, 2020
Sep 10, 2020BApt 2L · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHOct 15, 2020
Sep 10, 2020BApt 2L · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHOct 15, 2020
Sep 10, 2020BApt 2L · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHOct 15, 2020
Sep 10, 2020BApt 2L · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL, WEST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHOct 15, 2020
Sep 10, 2020AApt 2L · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE KITCHEN , THE 1st ROOM FROM EAST, THE 2nd ROOM FROM EAST, THE 3rd ROOM FROM EAST LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHDec 14, 2020
Sep 10, 2020BApt 2L · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL, WEST WALL, CEILING IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHOct 15, 2020
Mar 12, 2020CApt 1L · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHApr 16, 2020
Oct 22, 2007BApt 1L · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER AND LOWER SASH WINDOWS IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTNov 26, 2007
Dec 27, 2004C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM NO ACCESS TO CELLAR DOOR LOCKEDJan 7, 2005
Dec 1, 2004BApt 3L · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORYJan 10, 2005
Nov 29, 2004AApt 3L · § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3Mar 9, 2005
Nov 29, 2004BApt 3L · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 8, 2005
Sep 16, 2004C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM ON WALL AT PUBLIC HALL, 1st STORYSep 27, 2004
Apr 14, 2004C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM , AT PUBLIC HALL, 1st STORYApr 25, 2004
Feb 17, 2004CApt 1L · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LEAKY RADIATOR AIR VALUE SOUTH ROOM IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1L, 1st STORY, APARTMENT AT WESTFeb 28, 2004
Jan 30, 2002BApt 3L · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE (PAULETTE JONES) AT ENTIRE APARTMENT, 3rd STORY, APARTMENTMar 11, 2002

Issued in the last 120 days

DateSourceWhatNow
Jul 22, 2026HPD A§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTClosed
Jul 22, 2026HPD A§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE KITCHEN LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTClosed
Jul 22, 2026HPD A§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BASEBOARD AT NORTH AND EAST WALL IN THE KITCHEN LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTClosed
Jul 22, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTClosed
Jul 22, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE REFRIGERATOR DOOR GASKET SEAL IN THE KITCHEN LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTClosed
Jul 22, 2026HPD A§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET DOOR AT WEST WALL IN THE KITCHEN LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 4, 2026, 4:53 AM ET. BBL 3034300049.

Look up another building