Brooklyn · Block 5223 · Lot 99 · 11226

1258 Flatbush Avenue

3 floors · 2 apartments · 4,200 sq ft · built 1933 · class S9 · owner of record: Khan, Abdur Rab

19open violations
$0ECB/OATH penalties owed
3HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 427 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-11 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Apr 9, 2024Construction CLASS - 2
AT TIME OF INSPECTION, OBSERVED 1 STORY BUILDING A METAL STRUCTURE/CANOPY APPROX. 12 FT. H X 24 FT. W X 9 FT. D ERECTED AND ATTACHED TO THE BUILDING EXPOSURE # 1. OF 2332 & 2334 NEWKIRK AVE NO PERMIT ON FILE FO
#39111111H
Aug 2, 2024
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Feb 7, 2000LOCAL LAW 62/91 - BOILERS

#22047
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Feb 7, 2000Boiler LL6291
Active
HPD (16) · C 3 · B 13 · A 0
IssuedClassViolationCorrect by
Nov 20, 2017C§ 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING CONSISTING OF DOUBLE CYLINDER LOCK AT BUILDING ENTRANCE DOOR , 1st STORYNov 28, 2017
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC LIGHT FIXTURE AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRES AT CEILING IN THE KITCHEN LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRES AT CEILING IN THE BATHROOM LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC LIGHT FIXTURE AT CEILING IN THE FOYER LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRES AT CEILING IN THE FOYER LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRES AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC OUTLET AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC LIGHT FIXTURE AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRES AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC LIGHT FIXTURE AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011BApt 2 · § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRES AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 2, 3rd STORYSep 28, 2011
Aug 24, 2011C§ 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK, AT IRON DOOR AT BUILDING ENTRANCE AT PUBLIC HALL, 1st STORYAug 30, 2011
Sep 24, 2007C§ 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING CONSISTING OF DOUBLE CYLENDER LOCK AT ENTRANCE DOOR TO BUILDINGSep 30, 2007

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 4:06 AM ET. BBL 3052230099.