8 floors · 26 apartments · 25,872 sq ft · built 2014 · class D3 · owner of record: 1204 Broadway Owner Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 67 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 83 days | Annual |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $82,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 119 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 25,872 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 432 days | Next cycle year 2027 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-01 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 9, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#917974.REM:SUBMIT ACCEPTABLE REQUIRED T #37024603X | Mar 1, 2023 IN VIOLATION | $1,250 |
| Nov 16, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG FACADE&APPURTENANCES NOTE:ATOI OBSERVE EXP1E ELEVATION&EXP3W ELEVATION MAXIMUM BALCONY DEFECTIVE CONDITION.ALSO OBSERVED CRACKED STUCCO@NW CORNER.MAINTAIN EXTERIOR BLDG FACADE& #35669339L | Apr 26, 2023 IN VIOLATION | $625 |
| Sep 8, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES.AS NOTEDON EXPOSURE#1 EAST ELEVATION:I OBSERVED ON THE 8TH FLOOR GLASS PANEL BALCONY RAIL GAS KIT IS BREAKING LOOSE AT SOUTH EAST BALCONY LINE.UNDER #35664136Z | Feb 8, 2023 IN VIOLATION | $625 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15552 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #15553 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #19705 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #19706 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #40135 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #40136 | DOB VIOLATION - ACTIVE |
| Sep 22, 2022 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO SPALLING/DISPLACED UNDERSIDES OF BALCONIES AT EXP1 EAST AND 3 WEST ELEVATIONS. REMEDY: IMMED TAKE AND PROVIDE SAFETY MEASURE TO SECURE AND PROTECT THE PUBLIC AND INSTALL PUBLIC PROTECTION AT EXP1 AND 3 WEST. MAKED IMMED REPAIRS UNDER SUPERV OF A LIC PROF. ALSO REMOVE/SECU #FA1401WO | DOB VIOLATION - ACTIVE |
| Sep 22, 2022 | CONSTRUCTION FTM FACADE AND APPURTENANCES ON 09/22/2022 OBSERVED SPALLING,DISPLACED BLACONY UNDERSIDE AT EXP1 EAST AND EXP3 WEST. REMEDY: OWNER IS TO IMMED RETAIN SERVICE OF NYSPE WITH EXPERIENCE IN MASONRY AND STEEL BALCONIES AND GLASS RAILING SYSTEMS TO INSPECT AND EVALUATE 100% OF MASONRY #FA1402WO | DOB VIOLATION - ACTIVE |
| Sep 22, 2022 | CONSTRUCTION PARTIAL VACATE ORDER-OBSERVED ON 09/22/2022 BY FACADE INSPECTOR THERE ARE SPALLING,DISPLACED AND DEGRADED BALCONY UNDERSIDES AND LOOSE GASKETS AT GLASS RAILING SYSTEMS ON EXP1 EAST ELEV AND EXP3 WEST ELEV DUE TO THESE CONDITIONS ALL BALCONIES ON EXP 1 EAST AND 3 WEST ARE TO BE VACATED. REMEDY: VACAT #FA1403WO | DOB VIOLATION - ACTIVE |
| Feb 22, 2022 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 #02224 | DOB VIOLATION - ACTIVE |
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #08838 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Feb 22, 2022 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 | Active |
| Sep 6, 2019 | Elevators ACC1 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 31, 2026 | B | Apt 5D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE KITCHEN LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 5, 2026 |
| Aug 31, 2026 | B | Apt 5D · § 27-2005 HMC: REFIT DOOR IN THE ENTRANCE LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 5, 2026 |
| Aug 31, 2026 | C | Apt 5D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 26, 2026 |
| Jul 7, 2026 | A | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE COMPACTOR ROOM AT PUBLIC HALL, 5th STORY | Oct 10, 2026 |
| Oct 27, 2025 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AT FIRE DOOR TO STAIRCASE A AT PUBLIC HALL, 1st STORY | Dec 1, 2025 |
| Oct 27, 2025 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AT COMPACTOR CLOSET DOOR AT PUBLIC HALL, 7th STORY | Dec 1, 2025 |
| Oct 27, 2025 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MOTION SENSING ELECTROMAGNETIC LOCKING DEVICE AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Dec 1, 2025 |
| Aug 29, 2025 | B | § 27-2005 ADM CODE PROVIDE HEAVY DUTY LOCKSET AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Oct 3, 2025 |
| Aug 29, 2025 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING ELECTROMAGNATIC LOCKING DEVICE INSTALLED AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Sep 4, 2025 |
| Jun 27, 2025 | B | Apt 3A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Aug 1, 2025 |
| Jun 27, 2025 | B | Apt 3A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Aug 1, 2025 |
| Jun 27, 2025 | C | Apt 3A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 23, 2025 |
| May 13, 2025 | C | Apt 3A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 8, 2025 |
| Jan 28, 2025 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF KEY OPERATED DOUBLE CYLINDER LOCK INSTALLED AT BUILDING VESTIBULE DOOR | Feb 3, 2025 |
| Jan 24, 2025 | C | Apt 7C · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDS THE MAXIMUM OF 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 7C , 7th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jan 30, 2025 |
| Jan 24, 2025 | C | Apt 7C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 7C , 7th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Feb 19, 2025 |
| Sep 3, 2024 | B | Apt 2A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 30 SQ FT AT WOOD BASE CABINET IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 8, 2024 |
| Dec 26, 2023 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM ... AT BOILER ROOM, 1st STORY | Jan 1, 2024 |
| Dec 26, 2023 | C | Apt 8B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 8B, 8th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 21, 2024 |
| Dec 26, 2023 | C | Apt 8B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 8B, 8th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 21, 2024 |
| Oct 23, 2023 | C | Apt 8B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 8B, 8th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 18, 2023 |
| Oct 23, 2023 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT NORTH WALL AND CEILING AT PUBLIC HALL, 8th STORY | Nov 27, 2023 |
| Oct 23, 2023 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT NORTH WALL AND CEILING AT PUBLIC HALL, 8th STORY | Jan 26, 2024 |
| Oct 23, 2023 | C | Apt 8B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 8B, 8th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 18, 2023 |
| Sep 5, 2023 | C | Apt 8B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 8B, 8th STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 1, 2023 |
| Sep 5, 2023 | B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NORTH WALL AT PUBLIC HALL, 8th STORY | Oct 10, 2023 |
| Sep 5, 2023 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES AT STORAGE ROOM, 1st STORY | Oct 1, 2023 |
| Sep 5, 2023 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT VESTIBULE DOOR , 1st STORY | Sep 11, 2023 |
| Sep 5, 2023 | B | § 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY-DUTY LOCK AND LATCH SET AT VESTIBULE DOOR PUBLIC HALL , 1st STORY | Oct 10, 2023 |
| Jul 17, 2023 | B | § 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF POWER OUTAGE,BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY-DUTY LOCK AND LATCH SET ON VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Aug 21, 2023 |
| Jul 17, 2023 | C | Apt 2A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Aug 12, 2023 |
| Jul 11, 2023 | B | § 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF POWER OUTAGE ,BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY-DUTY LOCK AND LATCH SET ON VESTIBULE DOOR, AT PUBLIC HALL, 1st STORY | Aug 15, 2023 |
| Jul 5, 2023 | C | Apt 6D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jul 31, 2023 |
| Feb 8, 2023 | C | Apt 3D · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE MAXIMUM TEMPERATURE 130 DEGREES AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Feb 14, 2023 |
| Feb 8, 2023 | B | Apt 3D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 15, 2023 |
| Feb 8, 2023 | B | Apt 3D · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE METAL DOOR IN THE ENTRANCE LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 15, 2023 |
| Feb 8, 2023 | B | Apt 3D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 15, 2023 |
| Feb 8, 2023 | B | Apt 3D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 15, 2023 |
| Feb 8, 2023 | B | Apt 3D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 15, 2023 |
| Dec 4, 2020 | B | Apt 8A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 8, 2021 |
| Dec 4, 2020 | B | Apt 8A · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 8A, 8th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 8, 2021 |
| Date | Source | What | Now |
|---|---|---|---|
| Aug 31, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE KITCHEN LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Aug 31, 2026 | HPD B | § 27-2005 HMC: REFIT DOOR IN THE ENTRANCE LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Aug 31, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5D, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
| Jul 7, 2026 | HPD A | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE COMPACTOR ROOM AT PUBLIC HALL, 5th STORY | Open |
| Jul 7, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT PUBLIC HALL, 5th STORY | Closed |
| Jul 7, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT PUBLIC HALL, 2nd STORY | Closed |
| Jul 7, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT PUBLIC HALL, 3rd STORY | Closed |
| Jun 29, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER DOOR AT COMPACTOR CLOSET, 5th STORY | Closed |
| Jun 29, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT DOOR AT COMPACTOR CLOSET, 7th STORY | Closed |
| Jun 29, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ELECTRICAL OUTLET AT WEST WALL IN THE STORAGE ROOM AT NORTH | Closed |
| Jun 29, 2026 | HPD B | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF AT WEST WALL IN THE STORAGE ROOM AT NORTH | Closed |
| Jun 29, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER DOOR AT COMPACTOR CLOSET, 2nd STORY | Closed |
| Jun 29, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER DOOR AT COMPACTOR CLOSET, 7th STORY | Closed |
| Jun 29, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER DOOR AT PUBLIC HALL, 4th STORY | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 11:31 AM ET. BBL 3066940064.