1 floors · 4,952 sq ft · built 1910 · class G9 · owner of record: Cerke, Inc.

8open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
791dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 60 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 791 days
Next cycle year 2028

Open violations

ECB / OATH (3)
IssuedViolationHearingBalance
Oct 26, 1995Construction Non-Hazardous
FAILURE TO MAINTAIN DEFECT IS HOLE IN ROOF AT SOUTH SECTION @ ROTTED AND DEFECTIVE ROOT JOIST LATHING AND MATERIAL AT SOUTH SECTION AT VERIOUS LOCATION REMEDY REPAIR DEFECTIVE ROOF AT SOUTH SECTION REMEDY SUBMI
#34132233R
Jan 22, 1996
WRITTEN OFF
$0
May 31, 1995Construction Non-Hazardous
FAILURE TO MAINTAIN DEFECT IS 1-FIRE RATED CEILING MISSING IN ENTIRE FLOOR 2-WATER LEAKE IN THE ROOF VARIOUS LOCATION REMEDY REPAIR DEFECTS
#34125994X
Aug 14, 1995
WRITTEN OFF
$0
May 24, 1990Construction Non-Hazardous
FAILURE TO MANTAIN-ROOF BEAM ROTTEN, AND ROOF SAGGING AT FRONT AND MI-DDLE OF PREMISES. REMEDY:CHANGE ROTTED BEAM AND REPAIR SAGGING ROOF INA SAFE AND LAWFUL MANNER.
#34040805P
Jul 9, 1990
WRITTEN OFF
$0
DOB (4)
IssuedViolationStatus
May 25, 2010EMERGENCY

#1790
DOB VIOLATION - ACTIVE
Nov 9, 2006UNSAFE BUILDINGS

#3632/06
DOB VIOLATION
Jun 18, 1996CONSTRUCTION

#03AM011
DOB VIOLATION - ACTIVE
Jan 10, 1994CONSTRUCTION

#03W01
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 3)
Active