| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 65 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 65 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-17 (Accepted). Agency page | Dec 31, 2026 in 65 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 81 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 46,300 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 29, 2024 | Construction CLASS - 1 OBSERVED AT FACADE HAVE CRACKS AT MULTIPLE LOCATIONS, MISSING MORTAR JOINTS AT 1ST FLOOR APT WINDOW . LINTEL CORRODED ABOVE RIGHT AND LEFT PASSAGEWAY FROM SIDE-YARDS OF THE BUILDING. EXIT PASSAGEWAY FROM RIGHT #39120099Z | Oct 28, 2024 IN VIOLATION | $1,250 |
| Sep 22, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING. AT TIME OF INSP. OBSERVED FIRE ESCAPE PATHWAYS AT EXPOSURE #2/4 OBSTRUCTED BY STEEL GATE KEY LOCKING DEVICES, COMBUSTIBLE HOUSEHOLD GARBAGE & ITEMS ALONG WITH EXPOSURE #3 EXCESSIVE #39070603X | Jun 20, 2023 IN VIOLATION | $1,250 |
| Sep 22, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) & APPURTENANCES. AT TIME OF INSPECTION OBSERVED AT ENTIRE EXPO #1 MASONRY PARAPET WALL LEANING & BULGING SEVERELY WITH MISSING MORTAR AT JOINTS ALONG WITH SEVERE HORIZONTAL #39070604H | Jun 20, 2023 IN VIOLATION | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #27953 | DOB VIOLATION - ACTIVE |
| Aug 24, 2001 | CONSTRUCTION HAZARDOUS #09AH03 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 20, 2026 | B | Apt C3 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT C3, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTI | Nov 24, 2026 |
| Oct 20, 2026 | B | Apt C3 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT C3, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SEC | Nov 24, 2026 |
| Oct 20, 2026 | C | Apt C3 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT C3, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTHEAST'' | Nov 15, 2026 |
| Oct 13, 2026 | B | Apt 2C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT FIRE ESCAPE WINDOW IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTHEAST | Nov 17, 2026 |
| Sep 28, 2026 | C | Apt 2E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 24, 2026 |
| Sep 28, 2026 | A | Apt 2E · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT HEAT RISER PIPE IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 1, 2027 |
| Sep 28, 2026 | A | Apt 2E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER WINDOW SASH IN THE KITCHEN LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 1, 2027 |
| Sep 28, 2026 | B | Apt 2E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 2, 2026 |
| Sep 28, 2026 | A | Apt 2E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH NORTH 1 WINDOW IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 1, 2027 |
| Sep 28, 2026 | B | Apt 2E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 2, 2026 |
| Sep 28, 2026 | B | Apt 2E · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE IN THE 4th ROOM FROM NORTH LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 2, 2026 |
| Sep 28, 2026 | C | Apt 2E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 24, 2026 |
| Aug 31, 2026 | C | Apt 4H · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT ALL COLD WATER FIXTURES IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTHWEST | Sep 6, 2026 |
| Aug 31, 2026 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL BALCONIES ALL STORIES AT BUILDING FRONT AT FIRE ESCAPE | Dec 4, 2026 |
| Aug 31, 2026 | C | Apt 4H · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATHTUB IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTHWEST | Sep 6, 2026 |
| Aug 31, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF PLANT POTS AT 3RD STORY BALCONY AT BUILDING FRONT AT FIRE ESCAPE | Oct 5, 2026 |
| Aug 31, 2026 | C | Apt 4H · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT ALL COLD WATER FIXTURES IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTHWEST | Sep 6, 2026 |
| Aug 26, 2026 | B | Apt 3C · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 30, 2026 |
| Aug 26, 2026 | B | Apt 3C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER SASH OF 1ST WINDOW FROM WEST AT NORTH WALL IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 30, 2026 |
| Aug 26, 2026 | C | Apt 3C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 21, 2026 |
| Aug 26, 2026 | B | Apt 3C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RUBBER GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 30, 2026 |
| Aug 26, 2026 | B | Apt 3C · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 30, 2026 |
| Aug 19, 2026 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES AND ITS COMPONENTS AT 1ST STACK FROM EAST AT NORTH AT BULDING FRONT AT FIRE ESCAPE | Nov 22, 2026 |
| Aug 19, 2026 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES AND ITS COMPONENTS AT 3RD STACK FROM EAST AT NORTH AT BULDING FRONT AT FIRE ESCAPE | Nov 22, 2026 |
| Aug 19, 2026 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES AND ITS COMPONENTS AT 2ND STACK FROM EAST AT NORTH AT BULDING FRONT AT FIRE ESCAPE | Nov 22, 2026 |
| Aug 19, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWERPOTS AT BALCONY AT 2ND STACK FROM EAST AT NORTH AT BUILDING FRONT AT FIRE ESCAPE, 3rd STORY | Sep 23, 2026 |
| Aug 19, 2026 | B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE BUILDING FRONT YARD | Sep 23, 2026 |
| Aug 19, 2026 | A | § 27-2005 ADM CODE PROVIDE GARBAGE CANS WITH LIDS | Nov 22, 2026 |
| Aug 11, 2026 | B | Apt 2A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18774569 ISSUED 09-APR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIV | Sep 15, 2026 |
| Apr 27, 2026 | C | Apt 1E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''DEFG'', AT SOUTHEAST | May 23, 2026 |
| Apr 27, 2026 | B | Apt 1E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND EAST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''DEFG'', AT SOUTHEAST | Jun 1, 2026 |
| Apr 27, 2026 | B | Apt 1E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''DEFG'', AT SOUTHEAST | Jun 1, 2026 |
| Apr 27, 2026 | B | Apt 1E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH IN THE KITCHEN LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''DEFG'', AT SOUTHEAST | Jun 1, 2026 |
| Apr 27, 2026 | B | Apt 1E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''DEFG'', AT SOUTHEAST | Jun 1, 2026 |
| Apr 13, 2026 | C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | May 9, 2026 |
| Jan 26, 2026 | C | Apt 1F · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' | Jan 22, 2026 |
| Nov 19, 2025 | C | Apt 2E · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 3, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APAR | Dec 15, 2025 |
| Apr 7, 2025 | B | Apt 1H · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FROM EAST LOCATED AT APT 1H, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTHWEST | May 12, 2025 |
| Apr 7, 2025 | B | Apt 1H · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATORATIVE DOOR KNOB AT ROOM DOOR, LEADING TO FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1H, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTHWEST | May 12, 2025 |
| Feb 6, 2025 | C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | Mar 4, 2025 |
| Jul 2, 2024 | C | Apt 3C · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) EAST WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 3C, 3rd STORY, 1st APARTME | Jul 26, 2024 |
| Aug 8, 2023 | C | Apt 4F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER SASH COUNTER BALANCE ON SOUTH WALL WINDOWS IN THE 1st ROOM FROM EAST LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''south'' | Aug 14, 2023 |
| Mar 13, 2023 | C | Apt 1P · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1P, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 11, 2023 |
| Nov 28, 2022 | C | Apt 2P · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2P, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 26, 2022 |
| Sep 19, 2022 | A | Apt 2A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 23, 2022 |
| Aug 11, 2021 | B | Apt 3G · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WEST 1 WINDOW COUNTER BALANCE AT LOWER SASH IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 3G, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Sep 15, 2021 |
| Aug 11, 2021 | B | Apt 3G · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE EAST 1 AND EAST 2 WINDOW COUNTER BALANCE AT UPPER AND LOWER SASH IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 3G, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Sep 15, 2021 |
| Aug 13, 2015 | B | Apt 3J · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL CEILINGS AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 3J, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT NORTHWEST | Sep 17, 2015 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 20, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT C3, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTI | Open |
| Oct 20, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT C3, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SEC | Open |
| Oct 20, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT C3, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTHEAST'' | Open |
| Oct 13, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT FIRE ESCAPE WINDOW IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTHEAST | Open |
| Sep 28, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 28, 2026 | HPD A | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT HEAT RISER PIPE IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 28, 2026 | HPD A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER WINDOW SASH IN THE KITCHEN LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 28, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 28, 2026 | HPD A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH NORTH 1 WINDOW IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 28, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 28, 2026 | HPD B | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE IN THE 4th ROOM FROM NORTH LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Sep 28, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Aug 31, 2026 | HPD C | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT ALL COLD WATER FIXTURES IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTHWEST | Open |
| Aug 31, 2026 | HPD A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL BALCONIES ALL STORIES AT BUILDING FRONT AT FIRE ESCAPE | Open |
| Aug 31, 2026 | HPD C | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATHTUB IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTHWEST | Open |
| Aug 31, 2026 | HPD B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF PLANT POTS AT 3RD STORY BALCONY AT BUILDING FRONT AT FIRE ESCAPE | Open |
| Aug 31, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGE AT BUILDING ENTRANCE DOOR | Closed |
| Aug 31, 2026 | HPD C | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT ALL COLD WATER FIXTURES IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTHWEST | Open |
| Aug 26, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE BUILDING ENTRANCE DOOR IS BINDING WITH DOOR FRAME , 1st STORY | Closed |
| Aug 26, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 26, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER SASH OF 1ST WINDOW FROM WEST AT NORTH WALL IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 26, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 26, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RUBBER GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 26, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 19, 2026 | HPD A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES AND ITS COMPONENTS AT 1ST STACK FROM EAST AT NORTH AT BULDING FRONT AT FIRE ESCAPE | Open |